ABB 1SDA058175R1 Moulded Case Circuit Breaker - UL/CSA

Part Number: 1SDA058175R1
Manufacturer
ABB
Part number
1SDA058175R1

Quick Summary

ABB 1SDA058175R1 Moulded Case Circuit Breaker provides reliable overcurrent protection for industrial power distribution in automation panels. Engineers often face panel downtime, nuisance trips, and regulatory pressure when selecting protection devices that fit exact trip curves and mounting constraints. This unit carries UL/CSA listings, CE conformity, and RoHS compliance, helping streamline procurement and documentation. The rugged 3P design supports a 600 V AC system with 300 A rated operating current, and front-terminal fixed mounting simplifies installation in compact layouts. By pairing Tmax T series compatibility with proven protection performance, it delivers predictable operation, faster commissioning, and lower lifecycle costs for demanding automation environments.

Product Information

Extended Description

1SDA058175R1 ABB: C.BREAKER TMAX T5V 400 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC PR222DS/P-LSI R 300
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax T5 | Breakers - Packaging disposal information
Order Code US and Canada
T5V300CW
EAN
8015644604400
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
140 mm
Product Net Height
205 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
5.1 kg
Package Level 1 EAN
8015644604400
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T5
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Mechanical Durability
20000 cycle | 120 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 9.3 W
Rated Current (In)
300 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
600 V AC
Rated Uninterrupted Current (Iu)
400 A
Release
PR222DS/P-LSI
Release Type
EL
Short-Circuit Performance Level
V
Standards
UL
Sub-type
T5
Terminal Connection Type
Fixed Circuit-Breakers | Front
Test Voltage Max (Utest)
3500 V
Interrupting Rating acc. to UL489
(240 V AC) 200 kA | (480 V AC) 150 kA | (600 V AC) 100 kA
Data Sheet, Technical Information
9AKK105713A5947
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T5
GL Certificate
1SDL000163R0062
Instructions and Manuals
Tmax. T Generation - Low voltage molded case circuit breakers up to 1200 A - UL 489 and CSA C22.2 Standard
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature is a 3P fixed front-terminal design that enables quick wiring and straightforward panel integration. Business impact is faster installation, reduced commissioning time, and improved field reliability, especially in space-constrained control panels. Application spans industrial automation where robust protection and easy maintenance are essential, such as motor control centers and transformer feeders. Feature PR222DS/P-LSI release delivers selective tripping and enhanced safety, minimizing unplanned outages and safeguarding downstream equipment. Application includes critical power distribution in manufacturing lines and process controls, where fast, accurate disconnection is required to protect personnel and assets. Feature rated at 600 V AC and 300 A with UL 489 compatibility and a 8 kV impulse withstand, ensuring dependable performance in high-energy environments. Application includes high-energy drives and feeders in crossover industries. Feature front-terminal fixed mounting reduces space requirements and simplifies retrofits, improving install efficiency and reducing on-site errors. Business impact is lower installation labor and fewer miswiring issues during upgrades. Feature mechanical durability of 20000 cycles translates to longer service life and lower maintenance costs in frequent switching applications. Application includes automated production lines where devices cycle under load, delivering cost-effective protection. Feature RoHS compliance and CE declarations ensure regulatory alignment, supporting procurement and multi-site deployments.

Get a Quick Quote for a ABB 1SDA058175R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA058175R1? Enquire Now

FAQs

This unit features a fixed front-terminal design with a 3P configuration suitable for panel mounting. Ensure mounting space accommodates 140 mm width and 205 mm height, and verify clearances for front-access connections. Use appropriate torque on terminals and follow OEM enclosure guidelines to maintain performance and safety during maintenance.
Key specs include 3 poles, rated current of 300 A, rated operational voltage of 600 V AC, rated insulation voltage of 1000 V, and a power loss of 9.3 W per pole. It withstands up to 8 kV test voltage and offers UL 489-compatible interrupting ratings suitable for commercial and light-industrial circuits.
Yes. With a 3P configuration, high interrupting ratings, and front-terminal mounting, it is well-suited for motor control centers and transformer feeder protection in automation and process industries. It aligns with Tmax T series equipment, enabling coordinated protection schemes and predictable tripping behavior.
The product is UL-listed with CE conformity and RoHS compliant, supporting global procurement. It also references a Declaration of Conformity for CE and RoHS compliance, and packaging and environmental declarations align with current EU directives, simplifying regulatory reporting and cross-border sourcing.
Mechanical durability is rated at 20000 cycles, reducing maintenance frequency in dynamic environments. With 300 A capacity and efficient power loss profile (9.3 W per pole), the unit minimizes operational heat and energy waste, contributing to lower total cost of ownership over its lifecycle.