ABB 1SDA061848R1 Moulded Case CB - UL/CSA
Part Number: 1SDA061848R1
Quick Summary
The ABB 1SDA061848R1 Moulded Case Circuit Breaker protects motor and power circuits in industrial panels. Engineers often wrestle with delivering reliable protection while meeting strict regulatory requirements and minimizing downtime in harsh plant environments. This device holds UL/CSA listing, CE conformity, and RoHS compliance, with SCIP and CMRT declarations to streamline audits and supplier disclosures. Designed for seamless Tmax T integration, it enables straightforward front-terminal installation, scalable protection, and quick field replacement. By combining robust electrical performance with strong compliance, it supports safer operations, easier maintenance planning, and a clear path to cost-efficient panel modernization.
Product Information
Extended Description
1SDA061848R1 ABB: C.BREAKER TMAX T5V 600 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC PR221DS-LS/I R 600
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
5247a22d-5214-4315-9079-3bcc364d4d04 Italy (IT)
Simplified SCIP
15d2984a-b640-44c7-a6cb-77ef8ae3f643 Germany (DE) | b0886606-3b4e-4394-b986-84b333adee7c Netherlands (NL) | 39ef556d-2cd5-4f5e-87a1-0e34de924b1b Netherlands (NL) | 312073aa-7674-4892-9340-3d3c8bb10d21 Spain (ES) | 74fc65d6-e8fb-48f3-ad47-04b7da223cc3 Poland (PL) | 5c0a8795-8bda-421c-8e80-fad46b659a87 Netherlands (NL) | 15122e24-16de-49c2-a2e7-0447c8f0324d Netherlands (NL) | 0175bd36-ffc2-43a5-abdd-fbe33abe7159 Estonia (EE) | fd7a3f7b-1a7f-412d-bd93-ccdbe94adc21 Greece (GR) | 15d824fa-5e5d-4ab4-91ad-648f17d2b92e Portugal (PT) | cfc6849f-3724-40b2-b33d-c2e9e2c3fbb8 Bulgaria (BG) | 33f5d5ba-68a8-4934-97ab-07c20f07816a Sweden (SE) | 1d107862-af72-4fb8-8f14-34c89e53647c Poland (PL) | 2492555b-de5e-4ff9-b5de-cdf5b3439e50 Germany (DE) | 40543954-dc13-47c9-a7fb-c8d790964938 Denmark (DK) | ebaf8ca2-4a66-4412-bec2-b3db20977ae7 Germany (DE) | 1c0faa7b-5939-4b39-95de-0b1bdf536892 Sweden (SE) | 93461940-a5f0-4ec7-b2fa-195441c8002e Germany (DE) | 3d7320e7-0c39-44ad-ac5f-d7fc3baaec00 France (FR) | ff1aa2da-9b41-4eb8-a197-703cb4b4315a Czech Republic (CZ) | 24f8f2a5-40d5-4848-96b0-854508726964 France (FR) | 4202e61b-15ba-4390-bed6-f0d958d370e6 Poland (PL) | edbb314b-14e6-41b3-a3eb-dc2fb6be213f Norway (NO) | 1df558ab-ae8f-486a-b2e9-678f2dfbde44 Finland (FI) | c950d67f-b43f-419c-9506-a9a238b891f2 Croatia (HR) | f50b3127-b470-4fe7-905a-b2d94ddd9c55 Germany (DE) | 040f3f84-83d4-4508-af22-b8cb00af52ac Netherlands (NL)
Environmental Information
Product Environmental Information Tmax T5 | Breakers - Packaging disposal information
Order Code US and Canada
T5V600BW
EAN
8015644643836
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
140 mm
Product Net Height
205 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
5.1 kg
Package Level 1 EAN
8015644643836
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T5
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Mechanical Durability
20000 cycle | 120 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 37.1 W
Rated Current (In)
600 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
600 V AC
Rated Uninterrupted Current (Iu)
600 A
Release
PR221DS-LS/I
Release Type
EL
Short-Circuit Performance Level
V
Standards
UL
Sub-type
T5
Terminal Connection Type
Fixed Circuit-Breakers | Front
Test Voltage Max (Utest)
3500 V
Interrupting Rating acc. to UL489
(240 V AC) 200 kA | (480 V AC) 150 kA | (600 V AC) 100 kA
Data Sheet, Technical Information
9AKK105713A5947
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T5
Instructions and Manuals
Tmax. T Generation - Low voltage molded case circuit breakers up to 1200 A - UL 489 and CSA C22.2 Standard
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: The 3-pole, 600 A rated device delivers high-current protection with compact front-terminal wiring, reducing panel footprint and simplifying wiring during installation in switchgear and motor control centers. This leads to faster commissioning, lower labor costs, and improved uptime in continuous-process facilities. Feature → Business Impact → Application: PR221DS-LS/I solid-state release provides precise tripping coordination, enabling selective protection in warehouses, data centers, and processing lines, which minimizes unnecessary outages while preserving critical loads. Feature → Business Impact → Application: Mechanical durability rated at 20,000 cycles translates to longer service life under frequent switching, reducing maintenance intervals and total cost of ownership for manufacturing lines and utility substations. Feature → Business Impact → Application: RoHS, REACH, and SCIP declarations simplify compliance management and supplier audits across global operations, supporting cross-border deployment and risk mitigation. Feature → Business Impact → Application: 8 kV rated impulse withstand and 600 V insulation support safe operation in demanding grid interfaces, with front-fixed terminals that accelerate retrofit projects and reduce installation errors.
Get a Quick Quote for a ABB 1SDA061848R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA061848R1?
Enquire Now
FAQs
What you need to know: this is a 3P fixed-front-terminal device designed for straightforward retrofits and new installations in switchgear and motor control centers. Ensure compatibility with Tmax T system where a PR221DS-LS/I release is desired, verify conductor sizes against 600 A rating, and follow UL/CSA installation guidelines to prevent nuisance trips and ensure safe enclosure sealing.
Key performance ratings include a 600 A rated current, 600 V rated operational voltage, 1000 V rated insulation voltage, and an 8 kV rated impulse withstand. The device provides V short-circuit performance, UL 489/CSA C22.2 compliance, and 3P configuration, making it suitable for demanding industrial protection needs.
Yes. As part of the Tmax T family, the 1SDA061848R1 is intended for motor and transformer protection in distribution panels. Its 3P configuration, front-terminal connection, and PR221DS-LS/I release support coordinated protection schemes with reliable tripping and minimal downtime in motor control centers.
This device carries UL/CSA listings, CE conformity, RoHS compliance, REACH Declaration, CMRT for conflict minerals, SCIP registrations, and related environmental disclosures. These certifications facilitate cross-border deployment, regulatory audits, and sustainability reporting for industrial projects.
The product is rated for up to 20,000 mechanical cycles, reducing maintenance frequency. With a front-terminal design and robust short-circuit protection, it minimizes downtime during replacements and upgrades. The RoHS/REACH compliance and simplified spare-part compatibility also contribute to lower lifecycle costs and easier long-term service planning.