ABB 1SDA061850R1 Moulded Case Circuit Breaker - UL/CSA 600V

Part Number: 1SDA061850R1
Manufacturer
ABB
Part number
1SDA061850R1

Quick Summary

ABB 1SDA061850R1 is a molded case circuit breaker for industrial power distribution. Engineers often wrestle with maintaining uptime, ensuring reliable trip performance, and staying compliant across UL/CSA and RoHS requirements. This model carries UL/CSA certification and CE conformity, plus RoHS and REACH declarations, helping facilities meet global procurement standards. Its three-pole, 600 A rating and front-terminal design enable straightforward integration into switchgear and MCCs, reducing installation time and field wiring effort. By combining rugged protection with clear documentation, it supports safer maintenance, easier audits, and lower total cost of ownership in demanding industrial environments. Designed for Tmax T5 applications, it integrates with standard control schemes.

Product Information

Extended Description

1SDA061850R1 ABB: C.BREAKER TMAX T5V 600 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC PR222DS/P-LSIG R 600
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
7163f947-f653-4c12-b592-966201f33e67 Italy (IT)
Simplified SCIP
78970d77-d133-4e35-8ad1-db253b9d1d63 Germany (DE) | 191ec964-0092-42b4-8a5c-f0e5802311a9 France (FR) | 378e8c03-a3fe-4c8a-85ee-bb4d739ea140 Germany (DE) | 6ab23c51-abaa-41ed-992d-5fb1f43b61ef Netherlands (NL) | d1e69520-b1d5-4e9b-ae68-68f73683105a Poland (PL) | 06b75425-be4a-40b6-be26-df8d1d3affa3 Norway (NO) | 16477914-13d1-45c5-b356-3e28ea5c5c22 Croatia (HR) | d9477ff5-2854-468d-887f-68a5f2488e10 Finland (FI) | 7c51cc29-f1f0-46dc-9845-0070f286517c Czech Republic (CZ) | 882f2912-edca-468b-9ce3-f3c3dcfbbb14 Poland (PL) | 8be63962-c6e9-4acb-9929-a9e20622b5c3 Netherlands (NL) | 5d9ea5eb-7283-474b-a004-95fbc3942a27 Netherlands (NL) | 656c4515-78eb-4b8b-9fbe-28051a85fb4b Estonia (EE) | 87eae04f-a541-4004-b099-dc9f67f9df7f Greece (GR) | 0309df02-e17b-4938-9a51-34c18e638ad4 Portugal (PT) | 75af548d-d1ee-492e-abfd-078ec6c861b6 Bulgaria (BG) | 2719f8af-122e-4632-8373-1f89d145f93a Sweden (SE) | 014e980f-4ab1-42c2-a71e-ffcdfd5e71c4 Germany (DE) | 1b1f564a-562f-42be-ab06-a56cd89afc63 Sweden (SE) | e8e6e904-95a3-4a5d-ac86-840ba1854f25 France (FR) | 0f62d6f2-e4f0-41d1-bed7-aea2e2ae1152 Germany (DE) | b6b8145c-f1c0-4c92-9375-69b20598c43f Spain (ES) | fcf6e885-d793-4072-9123-03482ddd0662 Netherlands (NL) | f025e36f-0748-4fcb-8198-b1b2526dfca9 Denmark (DK) | 17e5d59a-b65d-4876-922a-cfbb158244e0 Poland (PL) | 521d0f5b-6285-4d6b-ad5e-452861b54c63 Germany (DE) | a83f6cf4-fd79-4e03-8708-219bb0410245 Netherlands (NL)
Environmental Information
Product Environmental Information Tmax T5 | Breakers - Packaging disposal information
Order Code US and Canada
T5V600EW
EAN
8015644643850
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
140 mm
Product Net Height
205 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
5.1 kg
Package Level 1 EAN
8015644643850
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T5
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Mechanical Durability
20000 cycle | 120 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 37.1 W
Rated Current (In)
600 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
600 V AC
Rated Uninterrupted Current (Iu)
600 A
Release
PR222DS/P-LSIG
Release Type
EL
Short-Circuit Performance Level
V
Standards
UL
Sub-type
T5
Terminal Connection Type
Fixed Circuit-Breakers | Front
Test Voltage Max (Utest)
3500 V
Interrupting Rating acc. to UL489
(240 V AC) 200 kA | (480 V AC) 150 kA | (600 V AC) 100 kA
Data Sheet, Technical Information
9AKK105713A5947
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T5
Instructions and Manuals
Tmax. T Generation - Low voltage molded case circuit breakers up to 1200 A - UL 489 and CSA C22.2 Standard
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: 3P 600 A rated current and 600 V AC capability provide scalable protection for large feeders. Business impact: reduces device count, simplifies protection coordination, and supports motor start-up protections in demanding lines. Application: ideal for MCCs and distribution panels in factories and process plants. Feature: Front-terminal fixed connection simplifies wiring, enables faster panel assembly, and reduces field termination errors. Application: particularly advantageous in compact switchgear where front access speeds installation and troubleshooting. Feature: PR222DS/P-LSIG solid-state release delivers fast, precise tripping, minimizing mechanical wear and nuisance trips. Business impact: higher uptime and more predictable protection coordination. Application: protective schemes for critical feeders and motors in continuous operation environments. Feature: Comprehensive material compliance including RoHS, REACH, and SCIP data supports global procurement and regulatory reporting. Application: procurement-ready for international projects and customer audits. Feature: Mechanical durability up to 20000 cycles and a high UL489 interrupting capacity provide long service life and robust protection under fault conditions. Application: heavy-duty industrial installations with frequent switching. Feature: Rated operational voltage of 600 V AC and fault current capabilities up to 200–100 kA (depending on voltage) ensure reliable protection for demanding electrical networks. Application: main feeders in manufacturing facilities, power distribution cabinets, and process lines.

Get a Quick Quote for a ABB 1SDA061850R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA061850R1? Enquire Now

FAQs

ABB 1SDA061850R1 is a fixed front-terminal breaker designed for easy machine integration. During installation, verify panel cutouts for 140 mm width and 205 mm height, secure terminals per torque specs, and maintain adequate clearance for front access. Its three-pole 600 A rating suits main feeders in switchgear and MCCs, reducing installation time.
PR222DS/P-LSIG is a solid-state release providing fast, precise tripping under overload or fault conditions. It minimizes mechanical wear, reduces nuisance trips, and improves repeatability across cycles. In practice, this translates to higher uptime for critical feeders and motors in continuous-operation facilities, with less downtime and safer protection coordination.
Yes. The Tmax T5 family, including 1SDA061850R1, carries a CE Declaration of Conformity and UL/CSA certification for North American installation. Material compliance includes RoHS and REACH declarations, ensuring restricted substances are controlled and documented. This supports regulatory compliance across global projects and customer audits. It also aligns with SCIP reporting obligations where applicable.
Designed for distribution panels, MCCs, and switchgear, this 3P 600 A breaker handles feeders and motor circuits in harsh industrial environments. With 600 V AC operating voltage, 8 kV impulse withstand, and front-access terminals, it supports reliable protection in compact spaces. Ideal for factories, processing lines, and utility sections worldwide.
With a robust mechanical durability rating of up to 20000 cycles and a solid-state release, maintenance intervals extend and nuisance trips drop, reducing downtime and service costs. The 600 A rating supports fewer components and shorter wire runs while keeping protection reliable during peak loads in continuous operations. This translates to lower lifecycle cost and improved plant availability.