ABB 1SDA061851R1 Moulded Case Circuit Breaker - UL/CSA
Part Number: 1SDA061851R1
Quick Summary
ABB 1SDA061851R1 is a moulded case circuit breaker providing overload protection for 600 V AC power distribution. Engineers often contend with nuisance trips and tangled wiring in compact control panels. UL/CSA certifications and CE conformity support safe, compliant integration across regional installations. By pairing robust protection with front-terminal ease, this MCCB helps panel builders shorten commissioning time and reduce field errors.
Product Information
Extended Description
1SDA061851R1 ABB: C.BREAKER TMAX T5N 600 MCP UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE IN AC PR221DS-I Iu 600 A
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax T5 | Breakers - Packaging disposal information
Order Code US and Canada
T5N600E5W
EAN
8015644643386
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
140 mm
Product Net Height
205 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
5.1 kg
Package Level 1 EAN
8015644643386
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T5
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Mechanical Durability
20000 cycle | 120 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 37.1 W
Rated Current (In)
600 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
600 V AC
Rated Uninterrupted Current (Iu)
600 A
Release
PR221DS-I
Release Type
EL
Short-Circuit Performance Level
N
Standards
UL
Sub-type
T5
Terminal Connection Type
Fixed Circuit-Breakers | Front
Test Voltage Max (Utest)
3500 V
Interrupting Rating acc. to UL489
(240 V AC) 65 kA | (480 V AC) 25 kA | (600 V AC) 18 kA
Data Sheet, Technical Information
9AKK105713A5947
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T5
Instructions and Manuals
Tmax. T Generation - Low voltage molded case circuit breakers up to 1200 A - UL 489 and CSA C22.2 Standard
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Three-pole design with front terminals and PR221DS-I magnetic release. Business Impact: Enables quick, reliable wiring and precise protection coordination in tight panel spaces. Application: Suitable for 600 V AC distribution boards, motor feeders, and transformer feeders in industrial facilities. Feature: Rated insulation voltage of 1000 V and test voltage up to 3500 V. Business Impact: Improves insulation reliability and surge withstand capability, reducing misapplication risk. Application: Ideal for higher insulation requirements in modern control cabinets. Feature: Interrupting rating per UL489 of up to 65 kA at 240 V, 25 kA at 480 V, and 18 kA at 600 V. Business Impact: Ensures reliable short-circuit clearance for heavy loads and peak demand scenarios. Application: Critical in transformer feeders and high-inrush motor circuits. Feature: Mechanical durability of 20000 cycles (120 cycles per hour). Business Impact: Extends service life, lowers maintenance frequency, and lowers lifecycle costs. Application: Suitable for frequently switched loads in continuous operation environments. Feature: Front-terminal connection design with fixed circuit-breaker mounting. Business Impact: Reduces wiring complexity and installation time, improving reproducibility in manufacturing lines. Application: Well-suited to new builds and retrofit projects in automation and power distribution panels. Feature: RoHS, REACH, CMRT, and TSCA compliance. Business Impact: Supports regulatory compliance across global operations, simplifying sourcing and audits. Application: Global deployments in North America and Europe with confidence in environmental standards.
Get a Quick Quote for a ABB 1SDA061851R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA061851R1?
Enquire Now
FAQs
This model uses fixed front-terminal connections, engineered for straightforward wiring within compact switchgear. Plan for secure busbar alignment and clean conductor routing to avoid impedance or contact reliability issues. The 3P design simplifies coordination across three phase paths, aiding consistent performance across feeders in industrial panels.
The device provides UL489-rated interrupting performance: up to 65 kA at 240 V, 25 kA at 480 V, and 18 kA at 600 V. It is rated for 600 V AC with Ui of 1000 V and Uimp of 8 kV, supporting reliable protection for demanding motor and transformer circuits.
Yes. With three poles, 600 A ratings, 600 V AC operation, front-terminal access, and high short-circuit withstand capability, it is well-suited for transformer feeder protection in industrial control panels. The PR221DS-I release enhances selectivity and fast clearing during faults in transformer feeders.
The MCCB carries UL recognition with CSA C22.2 compatibility and CE declaration of conformity. It also adheres to RoHS, REACH, CMRT, and TSCA environmental and compliance declarations, supporting global deployment and audit readiness in diverse regulatory environments.
The unit offers robust mechanical durability of 20000 cycles, reducing replacement frequency in cycling applications. With a measured power loss of 37.1 W per pole under rated conditions, energy effectiveness improves efficiency in continuous operation. Front-terminal design also shortens commissioning time, delivering tangible lifecycle and labor-cost savings.