ABB 1SDA061962R1 Moulded Case Circuit Breaker - IEC
Part Number: 1SDA061962R1
Quick Summary
The ABB 1SDA061962R1 Moulded Case Circuit Breaker protects industrial power distribution in switchgear applications. In demanding environments, engineers need reliable protection that minimizes nuisance trips and enables safe maintenance. This device carries IEC conformity, a CE declaration, and RoHS/REACH compliance, reinforcing regulatory alignment across global plants. With an 800 A rating in a 3P configuration and front-terminal connections, it supports compact, modular protection schemes without sacrificing performance. The release PR231/P-I enables precise coordination with upstream protection, while CMRT considerations reduce conflict minerals risk and waste. For new builds or retrofits, the unit integrates with Tmax T families to lower operating costs and improve system uptime, offering predictable performance in critical power architectures.
Product Information
Extended Description
1SDA061962R1 ABB: C.BREAKER TMAX T7S 800 FIXED THREE-POLE WITH FRONT TERMINALS AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR231/P-I R 800
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
EAN
8015644645007
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
210 mm
Product Net Height
268 mm
Product Net Depth / Length
154 mm
Product Net Weight
9.7 kg
Package Level 1 Units
1 piece
Package Level 1 Width
280 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
11.2 kg
Package Level 1 EAN
8015644645007
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
2000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 19.3 W
Rated Current (In)
800 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Uninterrupted Current (Iu)
800 A
Release
PR231/P-I
Release Type
EL
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0055
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39121100
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
The 800 A, three-pole design delivers robust protection for main feeders, reducing the risk of cascading faults and minimizing unplanned downtime. This high-current MCCB enables compact, modular switchgear layouts, leveraging front-terminal wiring for faster assembly and easier commissioning. Ics up to 85 kA and Icu up to 85 kA at various voltages provide strong short-circuit containment, improving system reliability and safety. Ui of 1000 V and Uimp of 8 kV ensure safe interruption across a broad operating range while maintaining insulation integrity. A low power loss of 19.3 W per pole supports energy efficiency and cooler enclosure operation, extending component life. RoHS/REACH and CMRT declarations simplify regulatory compliance, while PD-ready features support retrofit compatibility with Tmax T7 protection schemes. The PR231/P-I release enables precise coordination, reducing nuisance trips and improving selective protection in complex networks.
Get a Quick Quote for a ABB 1SDA061962R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA061962R1?
Enquire Now
FAQs
This 3P fixed-front-terminal MCCB is designed for straightforward panel mounting with standard DIN rail or panel cutouts. Ensure adequate clearance for lever operation and allow accessible wiring space behind the front terminals. Weighs about 9.7 kg and fits compact MCCB enclosures, enabling quick retrofits or new installs with minimal cabling complexity.
Key specs include In = 800 A, Ics up to 85 kA (depending on voltage), Icw up to 20 kA for 1 s, Ui = 1000 V, Uimp = 8 kV, and a rated operational voltage of 690 V AC. These values provide strong short-circuit protection while maintaining insulation integrity across the typical distribution network voltages.
Yes. The 1SDA061962R1 is part of the SACE Tmax T family and is designed to protect switchgear and transformer/generator installations. It supports coordination with upstream protection, front-terminal mounting, and a release mechanism that aligns with Tmax T7 protection schemes, enabling selective, reliable fault clearance.
The device carries IEC standards with a CE declaration and RoHS/REACH compliance, reducing regulatory risk. CMRT documentation is available for conflict minerals reporting, and TSCA declarations support U.S. regulatory alignment. These certifications help streamline procurement for globally regulated facilities.
With 2000 electrical durability cycles and 10000 mechanical cycles, the MCCB offers long operational life in demanding environments. Its front-terminal design reduces wiring time during maintenance, while the 19.3 W per pole power loss keeps operating temperatures manageable. These factors contribute to lower lifecycle costs and higher plant uptime.