ABB 1SDA061963R1 Moulded Case Circuit Breaker - 3P 800A

Part Number: 1SDA061963R1
Manufacturer
ABB
Part number
1SDA061963R1

Quick Summary

ABB 1SDA061963R1 Moulded Case Circuit Breaker provides overload and short-circuit protection for industrial electrical panels. In demanding plants, downtime from protection issues eats into throughput and maintenance budgets. This device aligns with IEC standards and CE conformity, backed by GL certification and SCIP registration for global procurement. Designed for 800A, 3P applications, front-terminal mounting, and PR231/P-LS/I release, it supports reliable, scalable panel design. By ensuring compliance with RoHS and REACH, procurement teams reduce regulatory risk. With robust electrical and mechanical durability figures, this model helps maintenance teams plan predictable service windows and extend asset life.

Product Information

Extended Description

1SDA061963R1 ABB: C.BREAKER TMAX T7S 800 FIXED THREE-POLE WITH FRONT TERMINALS AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR231/P-LS/I R 800
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
20af7e0b-41b1-4ca3-82df-5cfea62c16b2 Italy (IT)
Simplified SCIP
5ceed246-5550-4d20-b895-0298867fa0f0 Germany (DE) | ac1ec191-0c2a-46f3-be70-177a2a97207c Denmark (DK) | 18ecd63f-362c-42be-a3a6-a572b5c513fe Germany (DE) | a81779b2-5f3c-4582-bc5c-fb55ceffde7f Sweden (SE) | 517230f9-e9e3-4f99-bfd1-90b343f4ef2e Germany (DE) | a1e41ad9-2cc1-4827-8500-9e46a3f2b4c2 France (FR) | c5f6615b-52a3-4382-a518-6c7ce6a43cd1 Netherlands (NL) | c10223f9-293a-43ef-8401-2f433f6b3271 Spain (ES) | b700997c-4e5f-4b63-bc2c-2204f969d500 Poland (PL) | 2927acd6-0fbb-4009-888f-a46d7d0c850c Netherlands (NL) | 2760aad1-a57b-4533-8c5a-04a9e895026e Netherlands (NL) | b941f81f-e882-43ef-b0a3-04fbcfcbe66b Estonia (EE) | 922b8a7f-caca-4e74-b287-3fcd640dae53 Greece (GR) | 934c92ea-54d5-44bc-aa91-41ed67773458 Portugal (PT) | b20901f4-4162-4b8f-aeac-99084073b8ca Bulgaria (BG) | 479efe25-a746-4dfb-bc1d-ac28ae324cec Sweden (SE) | bce26540-9fbc-410c-9130-f7afba846e72 Poland (PL) | e9263878-d00e-42f3-bc43-d99110cb82d4 Germany (DE) | b3aa5ee0-5c2a-4141-8fc5-37bf8bea2b0d Netherlands (NL) | e12dec34-9829-443f-bdad-4c1937b54d4e Czech Republic (CZ) | f325e266-6edf-45c8-9248-60d906c04518 Poland (PL) | 52b39741-bc3f-4787-9708-24a339b90e17 France (FR) | ee5bf19e-22ff-4b14-b823-f9123f35e22d Netherlands (NL) | b2f7fb17-8e43-4e0d-8f29-0e7739c08453 Norway (NO) | 9ba368af-1da9-42a7-b47e-b1b42dca5a5a Finland (FI) | 38e141c4-b820-4b08-9c3d-45b1822ac962 Croatia (HR) | ee3920fe-4ae4-45f1-ba30-949187e56aef Germany (DE)
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
EAN
8015644645014
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
210 mm
Product Net Height
268 mm
Product Net Depth / Length
154 mm
Product Net Weight
9.7 kg
Package Level 1 Units
1 piece
Package Level 1 Width
280 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
11.2 kg
Package Level 1 EAN
8015644645014
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
2000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 19.3 W
Rated Current (In)
800 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Uninterrupted Current (Iu)
800 A
Release
PR231/P-LS/I
Release Type
EL
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0055
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39121100
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: High-current 3P design with fixed front terminals. Business impact: simplifies wiring, reduces installation time, and minimizes wiring errors, enabling higher panel density and quicker commissioning. Application: 690 V AC distribution, transformer protection, and motor feeder circuits in heavy industry where uptime matters. Feature: PR231/P-LS/I release with solid-state actuation. Business impact: precise, predictable tripping and better selectivity, lowering downstream damage and maintenance costs. Application: critical automation loops and process lines requiring reliable protection and fast response. Feature: Regulatory compliance package. Business impact: RoHS and REACH declarations, CE conformity, and SCIP registrations streamline supplier qualification and audits. Application: OEM panels and retrofit projects governed by European environmental and safety standards. Feature: Durability and lifecycle performance. Business impact: electrical durability up to 2000 cycles and mechanical durability up to 10000 cycles support long service intervals and lower total cost of ownership. Application: equipment in harsh factory floors and utility substations that demand durable protection devices. Feature: Installation ecosystem compatibility. Business impact: front-terminal, fixed-mount design integrates smoothly with ABB Tmax T protection schemes, reducing wiring variations and delays. Application: new builds or modernization programs across manufacturing, utilities, and data centers seeking streamlined procurement and support.

Get a Quick Quote for a ABB 1SDA061963R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA061963R1? Enquire Now

FAQs

Installation requires aligning the 3P fixed-front terminal design with the panel busbars and ensuring 690 V AC operation. Use the PR231/P-LS/I release for the preferred tripping characteristic, and follow the IEC installation practices specified in the data sheet. Verify clearances and torque specs for secure, compliant mounting to minimize thermal stress and allow easy maintenance.
The device is rated for In of 800 A with Ics up to 85 kA and Icu up to 30–85 kA depending on voltage, at a rated operational voltage of 690 V AC. It supports 3P configurations and 8 kV rated impulse withstand voltage, with a RoHS/REACH compliant build and CE conformity for global deployment.
Yes. Its high current rating (800 A), 3P configuration, front-terminal mounting, and robust short-circuit withstand make it well suited for transformer protection and motor feeder circuits in manufacturing, utilities, and data centers. The PR231/P-LS/I release provides precise protection, while the front terminals simplify retrofit and installation in existing ABB Tmax T ecosystems.
It carries CE conformity, a GL certificate, and SCIP registrations, along with RoHS and REACH declarations. These certifications support regulatory compliance, sustainable procurement, and traceability in global supply chains, helping audits pass smoothly and reducing compliance-related project risk.
With electrical durability up to 2000 cycles and mechanical durability up to 10000 cycles, maintenance windows can be scheduled predictably, reducing unplanned downtime. The device’s high selectivity, durable construction, and compliance alignment translate to lower lifecycle costs, fewer spare parts, and faster incident resolution in automation and power distribution applications.