ABB 1SDA061976R1 Moulded Case Circuit Breaker - IEC

Part Number: 1SDA061976R1
Manufacturer
ABB
Part number
1SDA061976R1

Quick Summary

ABB 1SDA061976R1 is a moulded case circuit breaker for high‑current protection in industrial power distribution. Installation can be complex when selecting front-terminal, four-pole protection, but this unit simplifies wiring while delivering reliable fault clearance. It meets IEC standards, CE conformity, and RoHS compliance, ensuring regulatory alignment and environmental responsibility. By choosing this Tmax T7 compatible breaker, you gain dependable overload protection with a front-terminal design that supports quick maintenance, reduced downtime, and long-term lifecycle cost savings for panel builders and end users.

Product Information

Extended Description

1SDA061976R1 ABB: C.BREAKER TMAX T7S 800 FIXED FOUR-POLE WITH FRONT TERMINALS AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR332/P-LI R 800
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
293e368c-3455-48a7-bee0-300f5c2a9a4f Italy (IT)
Simplified SCIP
20286860-b4ab-4a40-86a6-8f8743593788 Germany (DE) | c6fb76fa-15db-4bed-9e00-d07558c1132e Czech Republic (CZ) | 9de3fc29-1e22-450c-a4e8-dff469da2367 France (FR) | 9b88f98a-9f21-41b1-939b-574e4ff7bc12 Netherlands (NL) | 506c447f-c08b-45cc-af17-176f3ab06944 Denmark (DK) | d489b188-9462-4b08-8780-493a20828025 Germany (DE) | 99c7a8a8-46c7-431b-b33c-7c75a7a4e5bf Germany (DE) | 18d71a2a-7321-4d99-b3d9-8c7b09ff5ca8 Sweden (SE) | 22905ce0-a676-4552-baeb-fc74eb82260d Spain (ES) | c96b4217-fcb6-4ab6-92cd-615a5b4f2594 Poland (PL) | fcbfd966-342b-4121-9e09-bb70cfac2cb9 Bulgaria (BG) | aa2598cd-2419-437f-a0d1-9c7d8c8f2f40 Portugal (PT) | 13c44723-28e5-4e59-8f1d-406531464a0c Greece (GR) | 513b2fbf-bf9a-4f66-9e4d-e88f71e8f12a Estonia (EE) | 74142bf4-0d17-4442-8537-df633415fff0 Netherlands (NL) | 9cf7f488-5e24-473c-9b4d-919f1aed66f3 Netherlands (NL) | 6547de6f-621e-4774-9b25-9405ae97c7dc Sweden (SE) | 04dffc7e-8f96-48b3-8091-4baf8ac983f9 Germany (DE) | cf92485d-6e7a-4956-bab4-325c7c6043c4 Croatia (HR) | 8c4331e3-7a72-4e9e-a6fd-76013c50b99a Netherlands (NL) | 8ef5ff58-b676-4f0a-8209-d53844939427 Finland (FI) | a0b622d2-683e-4e60-a23e-095ded847b6d France (FR) | e8281bee-d2c2-4e41-888c-9b1763b6396b Poland (PL) | f04ef0a1-c1ec-4730-adc8-fff2a22bc78c Norway (NO) | 6b587ed5-520e-43d0-84c1-1f71d9056300 Netherlands (NL) | e842132a-0f4a-4e0b-89ea-b22a53c5ce27 Germany (DE) | f974e337-eb5f-42a8-b6af-8f54a2e9e389 Poland (PL)
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
EAN
8015644645229
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
280 mm
Product Net Height
268 mm
Product Net Depth / Length
154 mm
Product Net Weight
12.5 kg
Package Level 1 Units
1 piece
Package Level 1 Width
360 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
14 kg
Package Level 1 EAN
8015644645229
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
2000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 19.3 W
Rated Current (In)
800 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Uninterrupted Current (Iu)
800 A
Release
PR332/P LI
Release Type
EL
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0055
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39121100
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: The 4P fixed-front terminal design enables rapid installation and safer wiring, reducing commissioning time and minimizing field errors in control panels and switchboards. This translates to lower labor costs and faster project delivery for manufacturing lines and process plants. Feature → Business Impact → Application: The 800 A rated current supports robust protection for large motors and feeders, improving uptime and reducing unplanned outages in critical production lines. Feature → Business Impact → Application: PR332/P LI release provides selective tripping, enabling precise fault isolation and minimizing collateral disruption in transformer and generator protection schemes. Feature → Business Impact → Application: RoHS and REACH declarations mitigate regulatory risk across EU markets, supporting sustainable procurement and easier supplier audits for OEMs. Feature → Business Impact → Application: 8 kV impulse withstand and 690 V operating voltage ensure resilience in harsh electrical environments, delivering reliable protection in industrial environments such as metalworking, packaging, and chemical processing.

Get a Quick Quote for a ABB 1SDA061976R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA061976R1? Enquire Now

FAQs

This 4P fixed-front terminal breaker is designed for straightforward mounting in standard switchboards. Ensure proper clearance, torque on terminals per device spec, and correct alignment with busbars to avoid wiring stress. Use the front-access design for faster replacement and reduced downtime during maintenance.
Key specs include rated current 800 A, rated operational voltage 690 V AC, rated impulse withstand voltage 8 kV, and short-circuit breaking capacity up to 85 kA depending on voltage. It features 4 poles, PR332/P LI release, and a front-terminal connection compatible with Tmax T7 installations.
Yes. The product is aligned with SACE Tmax T family and is suitable for transformer and generator protection scenarios, offering reliable fault clearance with front-terminal mounting and a PR332/P LI release for selective tripping in high‑demand environments.
The unit adheres to IEC standards, carries CE conformity, and is RoHS compliant. Additional declarations include REACH and CMRT/SCIP classifications, supporting regulatory compliance across EU markets and responsible sourcing.
The front-terminal design simplifies wiring and servicing, reducing maintenance time. Its high-current rating and robust Ics/Icu performance reduce downtime risk during faults, improving line availability and lowering total cost of ownership in continuous‑production environments.