ABB 1SDA061990R1 Moulded Case Circuit Breaker - IEC
Part Number: 1SDA061990R1
Quick Summary
Moulded Case Circuit Breaker ABB 1SDA061990R1 protects 690 V systems in industrial power distribution and automation. Engineers face downtime from nuisance trips and difficult retrofits; this MCCB simplifies protection with a stored-energy mechanism and front-terminal design. CE conformity, RoHS and REACH declarations accompany IEC-compliant Tmax T7 technology for reliable, compliant installation. In practice, this 4-pole, 800 A MCCB with 690 V rating supports quick retrofits and predictable protection across MCCB-driven power systems. This combination delivers reliability in critical loads such as transformers, motors, and switchgear. Businesses benefit from reduced downtime, easier procurement, and traceable compliance across operations. Its robust design supports maintenance planning and long service life.
Product Information
Extended Description
1SDA061990R1 ABB: C.BREAKER TMAX T7S 800 FIXED FOUR-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR232/P-LSI R 800
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
Order Code US and Canada
T7MSFA4AC000000XX
EAN
8015644645366
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
280 mm
Product Net Height
268 mm
Product Net Depth / Length
178 mm
Product Net Weight
14 kg
Package Level 1 Units
1 piece
Package Level 1 Width
360 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
15.5 kg
Package Level 1 EAN
8015644645366
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7M
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
2000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 19.3 W
Rated Current (In)
800 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Uninterrupted Current (Iu)
800 A
Release
PR232/P-LSI
Release Type
EL
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0055
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
High-current capacity and a fixed front-terminal design enable reliable protection in switchgear and MCCB applications. With an 800 A rated current at 690 V AC and four poles, it reduces wiring complexity and simplifies installation while delivering strong fault protection for main feeders and transformer protection. The stored-energy PR232/P-LSI release provides fast, precise interruption and predictable reset behavior, which cuts nuisance trips and improves system availability in demanding manufacturing and process environments. The device also boasts a robust short-circuit performance: Ics up to 85 kA and Icu up to 85 kA (various voltages), plus a 20 kA short-time withstand current for 1 s, ensuring reliable shutdown under high fault conditions across critical loads. Power loss of 19.3 W per pole improves energy efficiency during continuous operation, contributing to lower operating costs over the asset lifecycle. Compliance is reinforced with IEC standards, RoHS and REACH declarations, and CMRT/TSCA documentation, supporting risk management and regulatory alignment for global deployments. Front-terminal, fixed-breaker installation simplifies retrofit workflows and reduces maintenance time, while the Tmax T7 family compatibility (Product Main Type SACE Tmax T) ensures seamless integration with existing protection schemes in transformer and switchgear configurations. This ABB MCCB also supports easy procurement with clear packaging data and a standard 1-piece unit, aiding project planning and inventory control. All told, the combination of performance, reliability and compliance helps engineers lower total cost of ownership while maintaining high availability in critical electrical networks.
Get a Quick Quote for a ABB 1SDA061990R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA061990R1?
Enquire Now
FAQs
This unit is a four-pole fixed breaker with front terminals, designed for straightforward panel mounting in switchgear. Ensure adequate space for front-access wiring, maintain clearances per your enclosure standards, and confirm compatibility with T7M or similar Tmax T7 configurations. The 280 mm width and 268 mm height fit typical MCCB racks, while the 360 mm packaging depth simplifies logistics planning.
Key ratings include rated current of 800 A, rated operational voltage of 690 V AC, and rated insulation voltage of 1000 V. Impulse withstand voltage is 8 kV, with short-circuit ratings Ics up to 85 kA and Icu up to 85 kA across selected voltages. A short-time withstand current (Icw) of 20 kA for 1 s supports rapid fault interruption. These specs ensure reliable protection for heavy-load feeders and transformer protection in industrial plants.
Yes. The device is part of the Tmax T7 family and carries a Product Main Type designation of SACE Tmax T. It features four poles, front terminals, and the PR232/P-LSI release, making it well-suited for transformer protection schemes and as a primary protective element in MCCB-based switchgear installations.
The unit ships with CE Declaration of Conformity and is RoHS and REACH compliant. Additional declarations cover CMRT for conflict minerals and TSCA compliance. This combination supports regulatory alignment across global sites and simplifies audit processes while ensuring safer, environmentally responsible operation.
Electrical durability is rated at 2000 cycles and mechanical durability at 10,000 cycles at 60 cycles per hour, with a per-pole power loss of 19.3 W. These values translate to predictable lifecycle costs and reduced maintenance intervals, contributing to lower total cost of ownership. The compact, front-terminal design also minimizes wiring effort during inspections and retrofits, accelerating project timelines and improving uptime.