ABB 1SDA062709R1 Moulded Case Circuit Breaker - PR332/P LI
Part Number: 1SDA062725R1
Quick Summary
Moulded Case Circuit Breaker protects industrial power distribution by interrupting fault currents in transformers, panels and switchgear. Engineers often confront nuisance trips, difficult front-terminal wiring, and escalating maintenance costs in aging installations. This ABB model leverages a three-pole design with front terminals and a lever-operated mechanism, delivering precise, reliable protection for Tmax T7 ecosystems. It carries IEC standards compliance and a CE declaration of conformity, with RoHS and CMRT/TSCA declarations supporting regulatory requirements. By aligning with RoHS and environmental expectations, it reduces compliance risk. For procurement and maintenance teams, the 1SDA062709R1 offers predictable performance, straightforward installation, and a clear path to lifecycle cost reduction while integrating with existing ABB Tmax components.
Product Information
Extended Description
1SDA062725R1 ABB: C.BREAKER TMAX T7V 800 FIXED THREE-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR332/P-LI R 800
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
Order Code US and Canada
T7MVFA3AP000000XX
EAN
8015644652746
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
210 mm
Product Net Height
268 mm
Product Net Depth / Length
178 mm
Product Net Weight
11 kg
Package Level 1 Units
1 piece
Package Level 1 Width
280 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
12.5 kg
Package Level 1 EAN
8015644652746
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7M
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
3000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 32 W
Rated Current (In)
800 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 200 kA | (230 V AC) 200 kA | (380 V AC) 150 kA | (400 V AC) 150 kA | (415 V AC) 150 kA | (440 V AC) 130 kA | (500 V AC) 100 kA | (690 V AC) 45 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 200 kA | (230 V AC) 200 kA | (380 V AC) 150 kA | (400 V AC) 150 kA | (415 V AC) 150 kA | (440 V AC) 130 kA | (500 V AC) 100 kA | (690 V AC) 60 kA
Rated Uninterrupted Current (Iu)
800 A
Release
PR332/P LI
Release Type
EL
Short-Circuit Performance Level
V
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0056
Wiring Diagram
Wiring diagram T7-T7M
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature to benefit to application: The 3P 800 A rating and 690 V AC operating voltage provide robust protection for high-load feeders, reducing the risk of costly equipment damage and unplanned downtime in manufacturing lines. Application: Suitable for distribution panels and motor feeders within industrial plants, delivering fast and reliable tripping during faults. Feature to benefit to application: Front terminals and fixed mounting enable quick wiring, simplified serviceability, and safer maintenance access, lowering installation time and fault-resolution costs in busy control rooms. Application: Ideal for retrofit projects in existing ABB Tmax T7 environments and new builds where serviceability matters. Feature to benefit to application: High short-circuit performance with Ics up to 200 kA and Icu up to 60 kA at relevant voltages ensures transformer and genset protection, minimizing arc faults and equipment damage during severe faults. Application: Critical protection in substations, switchgear, and large motor starters. Feature to benefit to application: Electrical durability rated at 3000 cycles and mechanical durability at 10000 cycles translate to longer service life with consistent operation, lowering maintenance frequency and spare-part costs. Application: Suitable for continuous duty in demanding industrial settings. Feature to benefit to application: RoHS, REACH, CMRT, and TSCA declarations align with global regulations and supply-chain expectations, reducing compliance risk and streamlining supplier audits. Application: Supports green manufacturing initiatives and regulatory readiness across Europe and North America. Feature to benefit to application: Compatibility with Tmax T7 ecosystems and front-terminal design simplifies integration with existing protection schemes, wiring diagrams, and documentation. Application: Accelerates commissioning in control rooms and plant-wide protection architectures.
Get a Quick Quote for a ABB 1SDA062725R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA062725R1?
Enquire Now
FAQs
Install the three-pole MCCB in a compliant panel using the front-terminal connections specified for fixed circuit-breakers. Refer to the wiring diagram 1SDC210015D0201 for correct terminal labeling and lever operation routine. Ensure the device is seated securely, the release PR332/P LI is correctly set, and that panel clearance and ventilation meet thermal requirements to prevent overheating.
The unit is rated for 800 A, 690 V AC, with an 8 kV rated impulse withstand voltage. It supports a short-circuit current rating up to 200 kA (Ics) and a ultimate short-circuit breaking capacity up to 60 kA (Icu) depending on voltage. It is designed for three poles and fixed front-terminal connections, balancing protection and maintainability.
Yes. With high Ics/Icu ratings, 3P configuration, fixed front terminals, and compatibility with Tmax T7 systems, it provides robust transformer protection. Its front-access design simplifies servicing in tight switchgear spaces, and the 800 A rating supports large transformer protection schemes common in manufacturing and utility-side installations.
The device aligns with IEC standards and carries a CE Declaration of Conformity. It also adheres to RoHS directives, REACH declarations, and CMRT/TSCA reporting. Environmental and regulatory documentation supports global procurement and compliance audits, reducing risk in multinational supply chains.
Mechanical durability of 10000 cycles and electrical durability of 3000 cycles translate to extended service life and fewer mid-life replacements. Combined with a front-terminal design and low power loss (32 W per pole), this reduces operating costs, lowers maintenance time, and improves overall reliability in continuous production environments.