ABB 1SDA062727R1 Moulded Case Breaker - PR332/P LSIG IEC

Part Number: 1SDA062727R1
Manufacturer
ABB
Part number
1SDA062727R1

Quick Summary

ABB 1SDA062727R1 Moulded Case Breaker is a high‑reliability overcurrent protector for low‑voltage distribution in industrial panels. It helps engineers prevent prolonged outages by delivering fast, selective tripping under fault conditions. The device complies with IEC standards and CE conformity, with RoHS and REACH declarations supporting sustainable procurement. Front terminals and a stored‑energy operating mechanism simplify installation and maintenance in tight spaces, while 3P operation at 690 V AC supports common industrial layouts. This solution pairs a robust 800 A rating with lifecycle performance, offering predictable downtime and cost efficiency for panel builders and service teams through easier replacement and enhanced protection for critical loads.

Product Information

Extended Description

1SDA062727R1 ABB: C.BREAKER TMAX T7V 800 FIXED THREE-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR332/P-LSIG R 800
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
Order Code US and Canada
T7MVFA3AS000000XX
EAN
8015644652760
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
210 mm
Product Net Height
268 mm
Product Net Depth / Length
178 mm
Product Net Weight
11 kg
Package Level 1 Units
1 piece
Package Level 1 Width
280 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
12.5 kg
Package Level 1 EAN
8015644652760
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7M
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
3000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 32 W
Rated Current (In)
800 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 200 kA | (230 V AC) 200 kA | (380 V AC) 150 kA | (400 V AC) 150 kA | (415 V AC) 150 kA | (440 V AC) 130 kA | (500 V AC) 100 kA | (690 V AC) 45 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 200 kA | (230 V AC) 200 kA | (380 V AC) 150 kA | (400 V AC) 150 kA | (415 V AC) 150 kA | (440 V AC) 130 kA | (500 V AC) 100 kA | (690 V AC) 60 kA
Rated Uninterrupted Current (Iu)
800 A
Release
PR332/P LSIG
Release Type
EL
Short-Circuit Performance Level
V
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0056
Wiring Diagram
Wiring diagram T7-T7M
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: 3P 800 A rating with LSIG release enables high-current protection with fast, selective tripping, reducing downstream faults and unplanned downtime in distribution panels and motor feeders. Application: ideal for industrial power distribution where reliability and quick fault isolation matter, such as CNC lines and packaging machinery. Feature → Business Impact → Application: Front terminals coupled with a stored‑energy operating mechanism cut installation time and improve safety during maintenance; technicians can perform front-access wiring and quick tripping tests in crowded control cabinets. Application: suitable for retrofit projects and new builds with limited cabinet depth. Feature → Business Impact → Application: 690 V AC rated insulation and 8 kV impulse withstand enhance safety margins in medium‑voltage LV networks; Ics up to 200 kA provides strong fault clearance across multiple voltages. Application: transformer and switchgear protection in LV distribution blocks. Feature → Business Impact → Application: IEC standards, CE conformity, and RoHS/REACH declarations mitigate regulatory risk and streamline procurement. Application: compliant with EU and global supply chains, supporting a broad ecosystem of partners. Feature → Business Impact → Application: Mechanical durability of 10000 cycles and electrical durability of 3000 cycles deliver longer service life and lower replacement costs. Application: reduces maintenance frequency in heavy-use environments like continuous manufacturing and process lines. Feature → Business Impact → Application: Product family fit and compatibility with Tmax T7M components simplify panel design and spare parts planning. Application: ideal for OEMs and integrators designing modular protection schemes with common spare parts inventories.

Get a Quick Quote for a ABB 1SDA062727R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA062727R1? Enquire Now

FAQs

Install the 3P MCCB with front terminals, following the included wiring diagram for T7‑family products. Ensure proper clearance for the stored‑energy mechanism, tighten terminals to the manufacturer’s torque specs, and mount in a suitable panel position for easy access during testing and maintenance. Verify 690 V AC ratings align with your system and perform a functional test after commissioning.
At 690 V, the device supports a rated service short‑circuit breaking capacity Ics up to 45 kA and a rated ultimate short‑circuit breaking capacity Icu up to 60 kA, depending on voltage level. The device also offers 1 s rated short‑time withstand current (Icw) of 15 kA, providing robust protection during transient faults.
Yes. The product is part of ABB Tmax T7 family with a Tmax T main type and is designed for low‑voltage distribution protection, including transformer feeder protection. Its 3P configuration, high current rating, fast release (PR332/P LSIG), and IEC compliance make it appropriate for transformer input and generator protection scenarios.
The breaker comes with CE conformity via the EC Declaration of Conformity, IEC standards compliance, and RoHS/REACH declarations. Additional documentation includes DoC‑CE, WEEE considerations, and CMRT reporting for responsible sourcing. These certifications support regulatory compliance and green procurement practices.
Electrical durability is rated at 3000 cycles and mechanical durability at 10000 cycles, facilitating longer service intervals and reduced maintenance downtime. Front-terminal design simplifies wiring and replacement, while the stored‑energy mechanism enables quicker testing and reset. Overall, this reduces total cost of ownership in high‑duty environments.