ABB 1SDA062748R1 Moulded Case Circuit Breaker - IEC
Part Number: 1SDA062748R1
Quick Summary
ABB 1SDA062748R1 moulded case circuit breaker provides reliable overload and short-circuit protection for 690 V distribution and motor-control panels. Engineers often face cramped spaces, front-terminal access challenges, and the need for predictable trip performance during surge events. This device carries IEC protection standards, CE conformity with a Declaration of Conformity, and RoHS/REACH declarations to simplify global sourcing. With a 4P fixed-front-terminal design and a 1000 A rating, it integrates cleanly into Tmax T installations, reducing wiring complexity, maintenance, and downtime. The result is safer panels, faster commissioning, and scalable protection for growing industrial networks.
Product Information
Extended Description
1SDA062748R1 ABB: C.BREAKER TMAX T7S 1000 FIXED FOUR-POLE WITH FRONT TERMINALS AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR331/P-LSIG R 1000
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
de8924c6-f4de-4223-a0b2-49c6d8cd7f73 Italy (IT)
Simplified SCIP
b36c2b0f-2053-40c2-825d-c5a278477a28 Germany (DE) | 5153a257-a4b0-492e-b04a-46feed86b3ee Germany (DE) | 58c99b7f-5c45-4e06-9dfa-116f1334b4b8 Finland (FI) | 5fd7cc2a-6f53-460a-9124-42b594b67c10 Netherlands (NL) | 1c1c11a0-51d1-4b66-afd4-cacd819344a7 Norway (NO) | 8de6493d-edc4-4ab7-a92b-b9de62e6fa10 Poland (PL) | 39f300d1-028d-4e49-a3dc-12152c2a1b0e Greece (GR) | 1450574a-fc8a-446d-8073-f064a4348bd9 Estonia (EE) | 6fbaa287-3720-453c-8b32-86a3c1dfd619 Portugal (PT) | 0ce6ae95-b6e5-4e30-8077-57a865393c76 Bulgaria (BG) | 5344073a-2dc4-491c-9436-eef5f29bb75d France (FR) | 08779909-cbba-44b1-9c42-e648822b4c17 Sweden (SE) | 14d5ed1b-f050-4d24-9467-b1c03350786e Poland (PL) | 2b20485d-cf3c-48a2-8306-36051894d04c Sweden (SE) | 50559127-f0a2-49aa-abaf-eedd0eaf5aa1 Germany (DE) | bcfc5f07-ce24-4d0a-b271-04545341f2fd Denmark (DK) | 30f0ca05-2b45-4ebd-b9a7-d49821db550b Germany (DE) | 917655cf-f42e-43ce-b4b8-bb5d11ffef8a Croatia (HR) | 19f6a41f-a70e-462d-b838-133dc1111a1d Poland (PL) | 422bb2e0-4eba-4ab1-b134-36346e014dd1 Czech Republic (CZ) | 44c48fa5-bee2-4115-8357-8b93d939742b Netherlands (NL) | 4ab23d90-7129-463d-a5d8-a7b7a4692d39 Netherlands (NL) | 077603c6-4e9d-4cb2-8eda-38e324c1cd5d Netherlands (NL) | b97b5232-f6f0-4e8e-a01a-a0ee824c761a Spain (ES) | 37015f6b-13c4-4679-893f-20741d7e31fd Netherlands (NL) | b938233c-6284-4fa5-b37e-1938fac3511f Germany (DE) | a56ef0fd-1711-4243-ac2a-caccfdd22fe8 France (FR)
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
EAN
8015644652975
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
280 mm
Product Net Height
268 mm
Product Net Depth / Length
154 mm
Product Net Weight
12.5 kg
Package Level 1 Units
1 piece
Package Level 1 Width
360 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
14 kg
Package Level 1 EAN
8015644652975
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
2000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 30 W
Rated Current (In)
1000 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Uninterrupted Current (Iu)
1000 A
Release
PR331/P LSIG
Release Type
EL
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0055
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39121100
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
The 4P fixed-front-terminal design with a lever-operated mechanism delivers crisp, reliable tripping, reducing on-site troubleshooting and panel downtime, which translates into lower maintenance costs and faster commissioning in power distribution and motor-control applications. By supporting a 1000 A rated current with robust 690 V AC operation, it accommodates high-load feeders while maintaining safety margins and precise coordination with upstream protection devices. The device delivers up to 85 kA short-circuit withstand across voltage ranges and 20 kA rated short-time withstand current for 1 second, ensuring continued operation during fault events and protecting critical equipment. Release PR331/P LSIG offers a solid-state-style, fast-acting trip with clear visual indication, simplifying diagnostics in demanding switchgear environments. RoHS, REACH, SCIP, CMRT compliance further reduces regulatory risk and simplifies global procurement, while power loss is minimized to 30 W per pole for energy-conscious installations. Durability specs—10000 mechanical cycles and 2000 electrical cycles—support long service intervals in busy facilities, helping minimize total cost of ownership and downtime.
Get a Quick Quote for a ABB 1SDA062748R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA062748R1?
Enquire Now
FAQs
This 4P fixed-front-terminal breaker is designed for straightforward panel mounting. Ensure correct orientation for front access, tighten terminal connections to the recommended torque, and verify clearance around the device for cooling and wiring. Use the PR331/P LSIG release to confirm proper tripping behavior, and follow the panel manufacturer's wiring diagram to maintain signal and control integrity during commissioning.
Important ratings include a rated current of 1000 A, rated operational voltage of 690 V AC, rated insulation voltage of 1000 V, and a rated impulse withstand voltage of 8 kV. Short-circuit performance includes Ics up to 85 kA (depending on voltage) and Icw of 20 kA for 1 s. Power loss is approximately 30 W per pole, aiding thermal management calculations.
Yes. The product carries RoHS information and REACH declarations, plus SCIP and CMRT data for conflict minerals reporting, aligning with EU and global regulatory expectations. This simplifies sustainability reporting and supplier compliance in cross-border projects.
The unit features a lever-operated release, a fixed-front-terminal design, and 4P configuration that integrates seamlessly with Tmax T switchgear. Its 1000 A rating and robust fault-current capabilities make it ideal for transformer and motor-control protection, reducing wiring complexity while delivering reliable, fast tripping when faults occur.
With 10000 mechanical cycles and 2000 electrical cycles, the device supports long maintenance intervals and predictable aging behavior. Low power loss (30 W per pole) reduces heat and energy consumption in operation, contributing to lower cooling loads and a lower total cost of ownership over the equipment lifecycle.