Quick Summary

ABB 1SDA062752R1 Moulded Case Circuit Breaker is a high-capacity protection device for switchgear and power distribution panels. Engineers commonly contend with wiring complexity, slow fault isolation, and regulatory alignment when sizing breakers for large loads. This unit carries IEC conformity with 690 V AC operation, 1000 A rated current, 4P front-terminal design, and solid-state release options, plus RoHS and REACH declarations for responsible sourcing. By combining robust protection with installation efficiency and comprehensive documentation, it supports reliable uptime, faster commissioning, and lower total cost of ownership across industrial facilities.

Product Information

Extended Description

1SDA062752R1 ABB: C.BREAKER TMAX T7S 1000 FIXED FOUR-POLE WITH FRONT TERMINALS AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR332/P-LSIRc R 1000
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
EAN
8015644653019
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
280 mm
Product Net Height
268 mm
Product Net Depth / Length
154 mm
Product Net Weight
12.5 kg
Package Level 1 Units
1 piece
Package Level 1 Width
360 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
14 kg
Package Level 1 EAN
8015644653019
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
2000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 30 W
Rated Current (In)
1000 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Uninterrupted Current (Iu)
1000 A
Release
PR332/P-LSIRc
Release Type
EL
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0055
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39121100
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Four-pole, fixed front-terminal design with PR332/P-LSIRc release. Benefit: Simplified wiring, reduced fault-finding time, and safer maintenance in high-density switchgear. Application: Large motor feeders and transformer protection in distribution panels. Feature: 1000 A rated current with 690 V AC operational voltage. Benefit: Supports high-load applications with margin for startup surges while preserving system stability. Application: Heavy-duty industrial drives and process lines requiring robust protection. Feature: High short-circuit withstand capabilities (Ics up to 30 kA at 690 V; Icu up to 30 kA at 690 V; Icw 20 kA for 1 s). Benefit: Enhanced system reliability and reduced equipment damage during faults. Application: Critical feeders in manufacturing plants and data-center-like environments. Feature: RoHS and REACH declarations plus CMRT and TSCA statements. Benefit: Regulatory compliance across regions, easing procurement and supplier audits. Application: Global rollouts and multi-site installations needing traceable sustainability data. Feature: Release versatility with EL type and PR332/P-LSIRc integration; CE declaration. Benefit: Precise tripping characteristics and documented conformity for safety certifications. Application: Protective solutions in power distribution and switchgear assemblies. Feature: Mechanical durability (10,000 cycles) and Electrical durability (2,000 cycles). Benefit: Longer service life, reduced maintenance cycles, and predictable performance under frequent switching. Application: High-cycling protection in dynamic processes and automation lines.

Get a Quick Quote for a ABB 1SDA062752R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA062752R1? Enquire Now

FAQs

This four-pole, front-terminal MCCB is designed for high-current distribution in switchgear and panel boards up to 690 V AC. It supports 1000 A continuous operation with solid-state release and fixed terminals for straightforward wiring, making it suitable for transformer protection and large motor feeders in industrial facilities.
Key specs include Rated Current In of 1000 A, Rated Operational Voltage Uo 690 V AC, Ui at 1000 V, Uimp of 8 kV, Ics up to 30 kA at 690 V, Icu up to 30 kA at 690 V, and Icw of 20 kA for 1 s. The unit has 4P configuration and front-terminal connections for reliable, high-capacity protection.
Yes. It carries IEC-based conformity with CE declarations, RoHS and REACH compliance for environmental and chemical restrictions, CMRT for conflict minerals, and TSCA declarations. Documentation supports regulatory audits and global procurement requirements.
The MCCB uses PR332/P-LSIRc release with EL type characteristics, enabling precise tripping under fault conditions. Front-terminal fixed connections simplify wiring and reduce maintenance time, while standardized documentation aids commissioning and safety verification across service teams.
With 10,000 mechanical cycles and 2,000 electrical cycles, the device offers long life in high-switching environments, reducing replacement frequency and downtime. Combined with robust protection (Ics/Icu margins) and regulatory compliance, this leads to lower total cost of ownership and faster, safer maintenance planning.