ABB 1SDA062764R1 Moulded Case Circuit Breaker - PR331/P LSIG
Part Number: 1SDA062764R1
Quick Summary
ABB 1SDA062764R1 Moulded Case Circuit Breaker provides high-current protection for industrial switchgear and transformers. Engineers often struggle with reliable release timing, front-access installation, and downtime when selecting MCCBs for dense control panels. This device carries CE conformity with IEC standards and RoHS/REACH declarations, plus TSCA alignment, ensuring regulatory compliance and peace of mind. Its 1000 A rating, 4P fixed-front design, and PR331/P LSIG release support scalable protection, while front terminals simplify installation and service, reducing downtime and maintenance costs.
Product Information
Extended Description
1SDA062764R1 ABB: C.BREAKER TMAX T7S 1000 FIXED FOUR-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR331/P-LSIG R 1000
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
Order Code US and Canada
T7MSFP4AE000000XX
EAN
8015644653132
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
280 mm
Product Net Height
268 mm
Product Net Depth / Length
178 mm
Product Net Weight
14 kg
Package Level 1 Units
1 piece
Package Level 1 Width
360 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
15.5 kg
Package Level 1 EAN
8015644653132
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7M
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
2000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 30 W
Rated Current (In)
1000 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Uninterrupted Current (Iu)
1000 A
Release
PR331/P LSIG
Release Type
EL
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0055
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
4-pole front-terminal design enables clean wiring and fast installation, reducing panel depth and wiring errors while speeding commissioning in large switchgear. Business impact: faster project delivery and lower labor costs during install and maintenance; Application: distribution boards and MCC installations in manufacturing facilities. The PR331/P LSIG stored-energy release provides precise, fast tripping with solid-state release, improving protection coordination and operator safety. Business impact: enhanced uptime and reduced risk of collateral damage during faults; Application: transformer protection and critical loads within Tmax T family equipment. A 1000 A rated current and 690 V AC rating support heavy-duty protection for high-load circuits, enabling scalable protection in data centers and process plants. Business impact: fewer outage events and improved reliability; Application: high-capacity feeders and motor control centers. Mechanical durability of 10000 cycles and electrical durability of 2000 cycles deliver a long service life in frequent operation environments, lowering lifecycle costs. Business impact: reduced replacement and maintenance expenses; Application: frequent switching scenarios in industrial automation. Robust short-circuit and surge capability—Ics up to 85 kA and Icu up to 85 kA with up to 8 kV impulse withstand—ensures resilient performance under transients. Business impact: higher fault tolerance and safer shutdowns; Application: critical power protection in heavy industries. Environmental and compliance declarations including RoHS, REACH, CMRT, and TSCA streamline procurement and regulatory alignment. Business impact: simplified compliance and risk management; Application: global deployments with strict supplier requirements.
Get a Quick Quote for a ABB 1SDA062764R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA062764R1?
Enquire Now
FAQs
This MCCB uses fixed front terminals, simplifying wiring runs and reducing panel depth. Ensure adequate clearance for terminal access, follow the product’s 690 V AC rating constraints, and plan for front-access maintenance to minimize service disruption. Verify compatibility with your enclosure and ensure correct torque settings on all terminals to prevent overheating.
The four-pole design distributes protection across four conductors, enabling coordinated protection for multi-phase feeders. With Ics up to 85 kA and Icu up to 85 kA across common voltage levels, it supports robust fault interruption and reliable shutdown sequences in medium-to-large switchgear applications.
Yes. The device is a Tmax T family MCCB with PR331/P LSIG release, designed for transformer and transformer-branch protection. Its 1000 A rating, 690 V operating voltage, and front-terminal configuration align with common transformer substation and distribution board protection requirements.
The product includes CE conformity with IEC standards, RoHS/REACH declarations, CMRT for conflict minerals, and a TSCA declaration. These certifications support regulatory compliance, ESG reporting, and supplier qualification during procurement.
LSIG stored-energy release enables reliable, predictable tripping with minimal actuation effort, reducing human error during maintenance tests. Combined with 2000 electrical and 10000 mechanical durability cycles, this improves uptime and lowers total cost of ownership in high-switching environments.