ABB 1SDA062852R1 Moulded Case Circuit Breaker protects electrical distribution in industrial control panels. Engineers often struggle with reliable protection and long wiring times in complex armoires, leading to downtime. This device aligns with IEC standards and CE conformity, and is supported by GL certification, RoHS/REACH declarations, and TSCA compliance for global manufacturing. With a 1000 A rating and Tmax T lineage, it delivers predictable protection while simplifying maintenance and panel integration, making it a strong fit for high-demand MCCB applications in manufacturing and process industries.
Product Information
Extended Description
1SDA062852R1 ABB: C.BREAKER TMAX T7V 1000 FIXED THREE-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR331/P-LSIG R 1000
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
Order Code US and Canada
T7MVFP3AE000000XX
EAN
8015644654016
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
210 mm
Product Net Height
268 mm
Product Net Depth / Length
178 mm
Product Net Weight
11 kg
Package Level 1 Units
1 piece
Package Level 1 Width
280 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
12.5 kg
Package Level 1 EAN
8015644654016
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7M
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
3000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 50 W
Rated Current (In)
1000 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 200 kA | (230 V AC) 200 kA | (380 V AC) 150 kA | (400 V AC) 150 kA | (415 V AC) 150 kA | (440 V AC) 130 kA | (500 V AC) 100 kA | (690 V AC) 45 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 200 kA | (230 V AC) 200 kA | (380 V AC) 150 kA | (400 V AC) 150 kA | (415 V AC) 150 kA | (440 V AC) 130 kA | (500 V AC) 100 kA | (690 V AC) 60 kA
Rated Uninterrupted Current (Iu)
1000 A
Release
PR331/P LSIG
Release Type
EL
Short-Circuit Performance Level
V
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0056
Wiring Diagram
Wiring diagram T7-T7M
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: The ABB 1SDA062852R1 is a fixed three-pole MCCB with front terminals and a stored-energy operating mechanism, delivering fast, repeatable tripping and simple wiring. This translates to reduced installation time and fewer commissioning errors on control panels used in automated processes. Application: ideal for new builds or panel updates in manufacturing lines where quick, reliable protection is critical. Feature → 1000 A rated current with 690 V AC operating voltage and 8 kV impulse withstand → Increased fault tolerance and safety margin for motor control centers and distribution boards; reduces risk of nuisance trips in high-power applications. Application: large MCCB protection in switchgear and transformer feeders. Feature → 3P design with PR331/P LSIG release and EL release type → Precise coordination with upstream protection and clear tripping signals; supports fast diagnostics and safe maintenance. Application: Tmax T7 families in process and automation environments. Feature → 3000 electrical cycles and 10000 mechanical cycles → Long service life minimizes replacement intervals and lowers lifecycle costs. Application: continuous-duty protective devices in manufacturing facilities. Feature → Front-terminal connection and RoHS/REACH/TSCA declarations → Easier wiring, safer terminations, and global compliance for cross-border projects. Application: panel builders supplying multinational OEMs with compliant protection for machinery and utilities.
Get a Quick Quote for a ABB 1SDA062852R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA062852R1?
Enquire Now
FAQs
This three-pole fixed-breaker is designed for front-terminal wiring, enabling straightforward field wiring and easy access during panel assembly. Ensure correct terminal torque values and alignment with panel cutouts to maintain reliable electrical contact and optimal tripping performance. The front-terminal design also supports cleaner enclosure layouts and faster maintenance checks in dense control cabinets.
The device is rated for 1000 A nominal current and 690 V AC operation, with a rated impulse withstand voltage of 8 kV. Short-circuit integrity is established with high Ics values across common voltages, supporting reliable protection for feeders and motor circuits. These specs enable safe coordination with upstream devices and transformers in industrial installations.
Yes. It carries a CE Declaration of Conformity and adheres to IEC standard requirements for Tmax T series circuit breakers. Additional compliance is evidenced by RoHS/REACH declarations and the GL certificate, supporting regulatory audits and global deployment in multinational facilities.
This MCCB is well-suited for protection of feeders, motor control centers, and transformer supplies within automated production lines. Its 3P configuration, front terminals, and stored-energy release enable rapid, reliable protection in panel boards and switchgear, aligning with Tmax T7 architectures and providing straightforward integration with compatible T7M components.
With 3000 electrical durability cycles and 10000 mechanical cycles at standard operating rates, the device offers a long service life, reducing replacement intervals. A modest per-pole power loss of 50 W supports energy efficiency in operation, while simplified wiring and robust tripping mechanisms lower downtime and maintenance costs in busy production environments.