ABB 1SDA062868R1 Moulded Case Circuit Breaker - PR331/P LSIG

Part Number: 1SDA062868R1
Manufacturer
ABB
Part number
1SDA062868R1

Quick Summary

ABB 1SDA062868R1 Moulded Case Circuit Breaker protects medium-voltage motor and transformer circuits by interrupting fault currents. Engineers often wrestle with space constraints, complex protection schemes, and downtime costs; this unit offers front-terminal access and a robust LSIG release for fast, reliable trips. This product carries CE conformity and IEC standards, with RoHS and REACH compliance ensuring regulated environments stay compliant. Designed for scalable protection in T7 applications, it reduces panel footprint without sacrificing performance, delivering improved uptime and easier maintenance through clear documentation and field-replaceable parts. For projects demanding high current, strong protection coordination, and dependable operation, this breaker provides a solid, future-ready solution for industrial power distribution.

Product Information

Extended Description

1SDA062868R1 ABB: C.BREAKER TMAX T7S 1250 FIXED THREE-POLE WITH FRONT TERMINALS AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR331/P-LSIG R 1250
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
3d74073a-b122-4bb1-acc4-9ee41c271652 Italy (IT)
Simplified SCIP
12a75ecf-7053-4ae6-9d6f-8721f30072ea Germany (DE) | 1b9df056-2d46-4708-97fc-65d774c29c1a Netherlands (NL) | 3452944f-e3fb-4816-bf2b-72f2e9175ccc Estonia (EE) | d34df109-231c-4abc-8559-0c7e2099cdd2 Greece (GR) | a0d04201-2ecd-47da-bea7-6ac2eecb87f2 Germany (DE) | ad30b132-11e4-4ab0-9a37-a7f86335a77d Croatia (HR) | 94db9e39-c982-4e5d-8065-016405bf8a49 Portugal (PT) | 6e4a2674-80ee-443b-aa31-3db59e44575b Netherlands (NL) | 7e087e2a-cb21-4f54-b19a-7ae8575cd9da Finland (FI) | f67d98a4-f044-4fe9-8b79-5efe4967713b Germany (DE) | b12c793c-b2b6-48ed-b388-03790c55e5f0 Denmark (DK) | 09ad2c90-47d2-4dce-aacb-cf2ee8cc2e55 Czech Republic (CZ) | 114930ea-498c-4d68-8749-35326fb312c6 Poland (PL) | bb30d2d9-63a6-4171-a52f-541196c3c386 Netherlands (NL) | fe07d273-cccf-4619-8ae9-5143dd098291 Bulgaria (BG) | 662c3c36-3a7a-456d-a3ee-d021da8c6d79 Sweden (SE) | 33c74e67-b322-418a-b46a-9f8ec6daa94f Poland (PL) | a02a902c-bcbc-4521-9037-ca910d41487e France (FR) | 2225fdd3-0f7c-436b-8a65-cb8ad023c9b8 Sweden (SE) | 798e2196-6e93-47e3-b5cc-8b6c4a84f390 France (FR) | 325f0bd9-2f6b-4a97-8d00-76b9f98b8b1f Netherlands (NL) | f8b28d96-1ad1-4093-953f-82a04d0b1e04 Spain (ES) | ef6e99dd-ab23-4434-999b-7e568bd3bac4 Netherlands (NL) | f66517ef-180b-429e-b8d7-3c1eccd8cbd0 Poland (PL) | 65acfc33-6789-4100-b28a-42a062e41def Germany (DE) | a8dd0949-f722-4a96-b177-c29e55a05b51 Norway (NO) | a8495260-8cf2-43cf-afde-44d5d4a1c270 Germany (DE)
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
EAN
8015644654177
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
210 mm
Product Net Height
268 mm
Product Net Depth / Length
154 mm
Product Net Weight
9.7 kg
Package Level 1 Units
1 piece
Package Level 1 Width
280 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
11.2 kg
Package Level 1 EAN
8015644654177
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
2000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 47 W
Rated Current (In)
1250 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Uninterrupted Current (Iu)
1250 A
Release
PR331/P LSIG
Release Type
EL
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0055
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39121100
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
High current capability with 1250 A rating enables reliable protection for large motor feeders and transformer circuits, reducing the risk of cascading faults and unplanned downtime while enabling scalable distribution to meet growing demands. Business impact includes improved uptime and safer distribution, with the application suitable for heavy-load panels in manufacturing and process facilities. The 3P fixed front-terminal design simplifies installation and service, delivering faster assembly and easier wiring checks in tight electrical rooms, reducing commissioning time and field errors in industrial environments. The PR331/P LSIG release provides precise, time-coordinated tripping, supporting selective coordination and reduced downstream damage in fault events. With a rated operational voltage of 690 V AC and Ui of 1000 V, the device supports robust protection across common industrial feeders, while the Icu/Ics values (up to 85 kA/50 kA) enable resilience against high fault currents. RoHS, REACH, and SCIP compliance streamline procurement for regulated industries, and the product’s footprint and weight (9.7 kg) support straightforward cabinet integration and panel upgrades. The device’s electrical durability of 2000 cycles and mechanical durability of 10000 cycles translate to predictable maintenance needs and lower lifecycle costs, while the packaging and data documentation simplify spare parts planning and compliance reporting. Typical applications include power distribution to transformers, motor control centers, and large machine feeds in petrochemical, metal fabrication, and packaging facilities, where fast, reliable disconnection is essential to preserve equipment and personnel safety. Compatibility with ABB SACE Tmax T7 lines ensures seamless integration into existing protection schemes and enables customers to leverage familiar engineering workflows and Spare Parts ecosystems.

Get a Quick Quote for a ABB 1SDA062868R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA062868R1? Enquire Now

FAQs

This unit uses fixed front-terminal connections and is a three-pole design, simplifying wiring and panel layout. Ensure adequate space for front terminals, confirm compatibility with enclosure cutouts, and verify mounting orientation matches the IEC-based protection scheme. Plan for proper cable sizing to support 1250 A continuous current and confirm adherence to local code requirements during retrofit or new installs.
Rated current In is 1250 A, rated operational voltage is 690 V AC, rated insulation voltage Ui is 1000 V, and rated impulse withstand voltage Uimp is 8 kV. The device provides Rated Short-time Withstand Current Icw of 20 kA for 1 s and Rated Service Short-Circuit Breaking Capacity Ics up to 85 kA (depending on voltage). It is a 3P breaker with a fixed front-terminal connection and a PR331/P LSIG release.
Yes. The 1SDA062868R1 is part of ABB’s Tmax T7 family, designed for moulded case protection in high-load feeders. Its 1250 A rating and LSIG release support reliable protection coordination for T7-based installations, including transformer feeds and motor circuits typical in process and manufacturing facilities.
The device carries CE conformity with a DoC for Tmax T7, along with IEC-based standards compliance. It also aligns with RoHS and REACH declarations, and SCIP data entries, aiding regulatory reporting and sustainable sourcing. This combination helps meet stringent procurement policies across global manufacturing and process industries.
Electrical durability is rated at around 2000 cycles and mechanical durability at 10000 cycles, with 60 cycles per hour operation. Plan preventive testing of release mechanisms at planned maintenance intervals and verify front-terminal connections during each service window. This reduces the risk of undetected degradation and supports predictable, budget-friendly lifecycle costs.