ABB 1SDA062882R1 Moulded Case Circuit Breaker - CE

Part Number: 1SDA062882R1
Manufacturer
ABB
Part number
1SDA062882R1

Quick Summary

ABB 1SDA062882R1 Moulded Case Circuit Breaker protects industrial power distribution during overload events. Engineers often grapple with undersized protection, downtime from nuisance trips, and complex retrofits. CE conformity, IEC standards compliance, and GL certification help ensure safe, reliable operation across Tmax T7-based systems. This solution supports rapid installation, robust protection at up to 1250 A, and easy integration with front-terminal MCCBs. By aligning with environmental and compliance programs such as REACH, RoHS, and SCIP, it supports sustainable, audit-ready operations across global sites. The design delivers reliable mechanical and electrical performance, minimizing downtime while meeting industry expectations for transformer protection, distribution panels, and machinery control circuits.

Product Information

Extended Description

1SDA062882R1 ABB: C.BREAKER TMAX T7S 1250 FIXED THREE-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR231/P-LS/I R 1250
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
d3222cc5-ce34-4efc-947d-811cf2811895 Italy (IT)
Simplified SCIP
123541cc-da4c-43bc-a7cb-6813937bb942 Germany (DE) | c40d6810-e866-474b-b66c-01e79e025beb Denmark (DK) | 2c4611f4-a81c-44f8-8442-196d1c150156 Czech Republic (CZ) | 8558fe70-0082-4fc8-8c53-c6c5f0c9444c Bulgaria (BG) | a6cff365-70b9-41df-b5f8-c516a21cb36c Germany (DE) | 2e85d923-20c1-44e7-bda7-f0a801779e70 Netherlands (NL) | 0b6c6c22-93ec-4fca-ac58-1c0594bd4533 Estonia (EE) | 5d1272d7-b340-4f10-bcb9-4a85a5c654a2 Greece (GR) | 9f49a4d5-5667-4055-85c9-05adc6e41490 Netherlands (NL) | c3695c60-e356-4c61-9d5b-20693d2df441 Finland (FI) | 1749f038-afd8-4f52-8206-3f8922903584 Portugal (PT) | 827b6de4-8115-4330-9025-3eeada2fc030 Norway (NO) | 57afdd08-a9af-4b02-b0c2-5fe879ca3267 Germany (DE) | 7b1d6184-4982-4b0a-9d23-d2918ccf898a Croatia (HR) | 905a79e6-8b4f-4a1b-a564-de9fcd95f89c Poland (PL) | 2b49d713-511a-4bd5-9e9f-c5a878534e5d Germany (DE) | 5c8d2e7d-1426-451a-afc8-4e8c7c1d4182 France (FR) | 947e2929-8aa0-41a0-b05b-a35051fa068b Netherlands (NL) | 485034eb-c020-454a-bb29-68cb7b169b46 Spain (ES) | 079ef8de-ead9-43d5-9368-0c599d8caf3e Netherlands (NL) | 04aef118-c67c-4441-aa77-94c6716e80bb France (FR) | 00f91c11-2e5c-4218-9da1-0d69b5f83754 Sweden (SE) | f76a2688-7248-4008-a3ca-87787842e286 Sweden (SE) | 4ba1aecf-7f61-43de-823f-192b5bbd5585 Poland (PL) | 50ac98a4-91a5-4f63-b8bc-a764c71c21ed Germany (DE) | e9f83d16-fa10-4fd8-98ae-d221ba215bb9 Poland (PL) | 09624d57-07cd-4ac7-853a-33bf0929919e Netherlands (NL)
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
EAN
8015644654313
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
210 mm
Product Net Height
268 mm
Product Net Depth / Length
178 mm
Product Net Weight
14.758 kg
Package Level 1 Units
1 piece
Package Level 1 Width
280 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
15.535 kg
Package Level 1 EAN
8015644654313
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7M
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
2000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 47 W
Rated Current (In)
1250 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Uninterrupted Current (Iu)
1250 A
Release
PR231/P-LS/I
Release Type
EL
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0055
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: 3-pole fixed-front terminal construction paired with a stored-energy operating mechanism and PR231/P-LS/I release.Impact: Ensures fast, repeatable tripping with minimal field maintenance and recalibration.Application: Ideal for main distribution boards and large incoming feeders where quick fault clearance reduces downtime. Feature: Rated current of 1250 A with 690 V AC operation and 1000 V insulation.Impact: Supports high-load feeders and transformer protection without oversized panels, reducing device counts.Application: Suitable for heavy-duty MCCs and industrial controls in demanding facilities. Feature: High fault capability with Ics up to 85 kA and Icu up to 85 kA at common voltages; Icw up to 20 kA for 1 s.Impact: Provides robust fault tolerance, protecting downstream equipment and improving safety margins.Application: Critical protection for transformer feeders and power distribution panels. Feature: Energy efficiency with 47 W power loss per pole.Impact: Lower heat generation reduces cooling requirements and running costs.Application: Continuous-operation panels where energy efficiency matters. Feature: RoHS, REACH, SCIP and CE declarations.Impact: Regulatory compliance across multiple markets, simplifying audits.Application: Global rollouts with consistent documentation. Feature: Front-terminal design facilitates installation and servicing.Impact: Faster wiring and easier retrofits.Application: Retrofit into existing panels with front-accessibility.

Get a Quick Quote for a ABB 1SDA062882R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA062882R1? Enquire Now

FAQs

This model uses a fixed front-terminal configuration and a 3P design, making wiring straightforward in 690 V panels. Ensure proper torque on terminals, adequate clearance for cooling, and compatibility with front-access wiring within your switchgear enclosure.
Key specs include a 1250 A rated current, 690 V AC rated operational voltage, 1000 V rated insulation voltage, 8 kV rated impulse withstand, Ics up to 85 kA, Icu up to 85 kA, Icw 20 kA for 1 s, and 47 W power loss per pole.
Yes. Its 3P fixed-front design, high short-circuit ratings, and Tmax T7 family compatibility make it suitable for transformer feeders and main distribution panels where reliable protection and fast tripping are needed.
The device carries CE Declarations of Conformity, GL certification, and material compliance declarations (RoHS, REACH, SCIP), aiding audit readiness and global deployment.
With a stored-energy mechanism, front-terminal wiring, and robust mechanical durability (10,000 cycles) plus electrical durability (2,000 cycles), downtime is reduced and maintenance is simplified, yielding lower lifecycle costs in high-demand facilities.