ABB 1SDA062892R1 Moulded Case Circuit Breaker delivers reliable overload and short-circuit protection for industrial panel boards. Operators often struggle to achieve fast fault clearance while maintaining serviceability and spare-part compatibility. This device aligns with IEC standards and CE conformity, with RoHS, CMRT, and TSCA declarations supporting regulatory and sustainability goals. In practice, you gain predictable coordination with Tmax T7 family breakers and faster commissioning for critical protection schemes. By selecting this model, procurement benefits from single-source compatibility, front-terminal accessibility for easier maintenance, and a clear path to meeting environmental and safety commitments. In sum, it supports reliable uptime, regulatory alignment, and total cost of ownership reductions in demanding electrical protection roles.
Product Information
Extended Description
1SDA062892R1 ABB: C.BREAKER TMAX T7S 1250 FIXED FOUR-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR331/P-LSIG R 1250
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
Order Code US and Canada
T7MSFB4AE000000XX
EAN
8015644654412
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
280 mm
Product Net Height
268 mm
Product Net Depth / Length
178 mm
Product Net Weight
14 kg
Package Level 1 Units
1 piece
Package Level 1 Width
360 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
15.5 kg
Package Level 1 EAN
8015644654412
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7M
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
2000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 47 W
Rated Current (In)
1250 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Uninterrupted Current (Iu)
1250 A
Release
PR331/P LSIG
Release Type
EL
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0055
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
High-current four-pole design provides coordinated protection for three-phase loads and neutral conductors, reducing fault propagation and simplifying panel wiring. Business impact: fewer miscoordination events and shorter troubleshooting times, translating to higher plant uptime and lower maintenance costs. Application: motor control centers, switchgear assemblies, and power distribution cabinets in manufacturing and processing facilities. Front-terminal fixed connections plus a stored-energy operating mechanism (SEOM) with PR331/P LSIG release enable quick, reliable tripping and straightforward field servicing. Business impact: faster installation and simpler preventive maintenance with reduced commissioning time. Application: new builds and retrofit projects in industrial electrical rooms where accessibility matters. Ics and Icw ratings—up to 85 kA at various voltages and 20 kA for 1 s—deliver robust fault current management. Business impact: enhanced protection margins and safer outage recovery. Application: critical process lines and high-load feeders. RoHS, REACH, CMRT, and TSCA declarations help compliance teams reduce sourcing risk. Business impact: regulatory readiness and smoother supply chains. Application: procurement for global manufacturing sites demanding green and compliant components. Mechanical durability of 10,000 cycles and electrical durability of 2,000 cycles extend service life. Business impact: lower replacement frequency and reduced spare-part inventories. Application: continuous process industries with frequent switching. Size and weight—280 mm wide, 268 mm high, 178 mm deep, about 14 kg—facilitate enclosure planning. Business impact: easier integration into standard switchgear frames and reduced installation complexity. Application: modular power distribution in new and existing facilities.
Get a Quick Quote for a ABB 1SDA062892R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA062892R1?
Enquire Now
FAQs
The 1SDA062892R1 uses fixed front-terminal connections and a four-pole configuration designed to fit standard industrial switchgear footprints. It is compatible with Tmax T7-based panels and similar moulded case circuit breakers, enabling straightforward panel integration and consistent protection across multi-branch feeders.
This device delivers a rated current of 1250 A, rated operational voltage of 690 V AC, and a rated impulse withstand voltage of 8 kV. It provides a short-circuit breaking capacity up to 85 kA (at applicable voltages) and a 20 kA short-time withstand current for 1 s, supporting high fault-current scenarios typical in industrial plants.
Yes. The product carries RoHS and REACH declarations, CMRT guidance for conflict minerals, and TSCA declarations, ensuring regulatory alignment and responsible sourcing for global procurement needs.
The PR331/P LSIG release provides a reliable stored-energy mechanism for fast, predictable tripping, improving selective coordination and reducing the risk of nuisance trips. This is especially valuable in complex drive and motor protection schemes where precise timing matters.
With 2,000 electrical cycles and 10,000 mechanical cycles, the unit offers long service life and stable protection performance. Its front-terminal design also simplifies wiring and field servicing, lowering maintenance time and inventory needs while supporting longer replacement intervals and predictable budgeting.