ABB 1SDA062987R1 Moulded Case Circuit Breaker - 4P 690V

Part Number: 1SDA062987R1
Manufacturer
ABB
Part number
1SDA062987R1

Quick Summary

ABB Tmax T7V 4P Moulded Case Circuit Breaker protects critical power feeders in industrial facilities. Engineers often battle downtime caused by bulky protection devices that are hard to install and maintain with front-terminal configurations. This solution aligns with IEC standards, offers CE conformity, and RoHS compliance, while CMRT and TSCA declarations support responsible sourcing. With a 1250 A rating, 8 kV impulse withstand, and a front-fixed design, it delivers reliable protection for heavy-duty distribution networks, reducing maintenance windows and ensuring safe, compliant operation. Leverage this MCCB for transformer and generator protection, while benefiting from installation efficiency and enhanced uptime across manufacturing, energy, and process industries.

Product Information

Extended Description

1SDA062987R1 ABB: C.BREAKER TMAX T7V 1250 FIXED FOUR-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR232/P-LSI R 1250
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
EAN
8015644655365
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
280 mm
Product Net Height
268 mm
Product Net Depth / Length
178 mm
Product Net Weight
14 kg
Package Level 1 Units
1 piece
Package Level 1 Width
360 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
15.5 kg
Package Level 1 EAN
8015644655365
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7M
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
3000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 78.3 W
Rated Current (In)
1250 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 200 kA | (230 V AC) 200 kA | (380 V AC) 150 kA | (400 V AC) 150 kA | (415 V AC) 150 kA | (440 V AC) 130 kA | (500 V AC) 100 kA | (690 V AC) 45 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 200 kA | (230 V AC) 200 kA | (380 V AC) 150 kA | (400 V AC) 150 kA | (415 V AC) 150 kA | (440 V AC) 130 kA | (500 V AC) 100 kA | (690 V AC) 60 kA
Rated Uninterrupted Current (Iu)
1250 A
Release
PR232/P-LSI
Release Type
EL
Short-Circuit Performance Level
V
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0056
Wiring Diagram
Wiring diagram T7-T7M
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: The 4P fixed front-terminal design simplifies assembly and future servicing, reducing installation time and minimizing field wiring errors in panelboards and switchgear housings. This translates to lower labor costs and faster commissioning for new projects or plant upgrades, especially in high-current feeder circuits. Feature → Stored-energy PR232/P‑LSI release → Business Impact → Application: Stored-energy operating mechanism enables quick, reliable tripping and easier manual operation in maintenance outages, which improves safety and reduces downtime during protective trips in heavy-load environments. Feature → Rated current 1250 A and rating up to 690 V AC → Business Impact → Application: Handles demanding feeder protection with high short-circuit capability, enabling compact layouts and fewer devices in large facilities such as data centers, steel mills, and chemical plants. Feature → Uimp 8 kV and Ui 1000 V → Business Impact → Application: High insulation and impulse withstand enhance reliability in harsh electrical environments, supporting compliance for transformer and generator protection schemes in outdoor or rugged installations. Feature → RoHS, REACH, CMRT, and TSCA declarations → Business Impact → Application: Ensures regulatory compliance and responsible sourcing, reducing risk in procurement audits and enabling broader market access. Feature → Power loss 78.3 W per pole → Business Impact → Application: Power-loss data helps optimize cooling and energy management in switchgear rooms, contributing to total cost of ownership reductions over the system lifetime.

Get a Quick Quote for a ABB 1SDA062987R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA062987R1? Enquire Now

FAQs

The 1SDA062987R1 uses fixed front terminals designed for standard MCCB enclosures. Ensure panel space for a 4P device, follow the wiring diagram, torques per terminal, and observe 690 V AC rating. Use proper PPE and validated latching if required by your panel design to simplify future maintenance.
Key specs include rated current 1250 A, rated operational voltage 690 V AC, rated insulation voltage 1000 V, rated impulse withstand voltage 8 kV, and short-circuit ratings up to 200 kA depending on voltage. It has 4 poles and uses PR232/P-LSI release with a total power loss of about 78.3 W per pole.
Yes. The device carries RoHS compliance with EU Directive 2011/65/EU and amendment 2015/863, a REACH declaration, and a CE declaration of conformity for Tmax T7. It also aligns with related sustainability and regulatory requirements, supported by CMRT and TSCA documentation.
Ideal for high-current feeders protecting transformers, generators, and heavy distribution networks in manufacturing, energy, and process industries. The model’s front-terminal design and high Ics/Icu ratings support reliable protection in rugged environments and where space efficiency in switchgear is critical.
The stored-energy PR232/P-LSI release enables quick trips and safer manual operation, reducing maintenance time. Front-terminal configuration simplifies servicing, while high durability and regulatory compliance lower downtime and risk, contributing to an overall reduction in operating costs over the device life cycle.