ABB 1SDA062995R1 Moulded Case Circuit Breaker - CE
Part Number: 1SDA062995R1
Quick Summary
The 1SDA062995R1 is a moulded case circuit breaker for high-current 690 V AC distribution. Engineers face challenges with reliable, front-terminal protection that fits compact panels and minimizes wiring complexity. This device adheres to CE/IEC standards and SCIP declarations, with RoHS and REACH compliance to support safe, regulator-ready installations. Designed for the Tmax T7 family, it helps reduce wiring time and maintenance costs while delivering predictable, documented performance. With 3 poles, 1600 A rating, 8 kV impulse withstand, front terminals, and PR232/P-LSI release, it ensures robust protection for feeders and transformers. The compact footprint, clear front-access wiring, and comprehensive documentation support faster procurement, safer installation, and easier ongoing maintenance.
Product Information
Extended Description
1SDA062995R1 ABB: C.BREAKER TMAX T7S 1600 FIXED THREE-POLE WITH FRONT TERMINALS AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR232/P-LSI R 1600
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
51f49441-0e0c-4409-99af-ef7a0b1e36b8 Italy (IT)
Simplified SCIP
44995675-0738-4d5f-8516-c6058b7ab7a5 Germany (DE) | fbf95541-c9df-4d40-8656-463e0a70e31f Poland (PL) | 86a70fed-fbf5-410b-bf7a-bf2acfcd80f1 Portugal (PT) | 6b5e2eb1-0e08-451c-a3d1-356f20360cd6 Netherlands (NL) | 3257062c-22ce-49b5-935f-90132f06bcbd Czech Republic (CZ) | 9f5bfebc-a5fe-435c-8abf-73f26362e268 Bulgaria (BG) | 2f35fe8c-f2b0-46f5-8d8b-804389b82732 Germany (DE) | 12265c7a-0e37-4788-97ef-0dd0c21dcd6d Sweden (SE) | 8bec68bc-9765-4b9f-a3cb-30cca6e44c23 France (FR) | 4e82b7ca-d858-4526-b964-289b0ac25aa2 Poland (PL) | 0e646c24-4e93-43b4-93a4-a72c33153ffd Germany (DE) | a78fb947-d0e4-43db-b653-e624d17c2648 Croatia (HR) | 64c9f31f-b68f-4825-9635-0ea697268d76 Netherlands (NL) | 75c1a5b1-1c8c-4654-9452-3c18c7b32ea3 Netherlands (NL) | f0047926-c60a-4cee-b3b7-db7dcd2049c7 Estonia (EE) | 6002c680-f40c-4827-ad9c-7256f1888b6b Greece (GR) | 6a9b0370-4af5-45fc-b5f9-e61de41934e8 Germany (DE) | 272b4302-1672-4b07-94d8-e12105e293fd France (FR) | efa3b9e4-1b59-49da-aee0-225cc357966e Netherlands (NL) | 661cbaa8-9a4e-4861-8e4b-8cbc4e26b337 Spain (ES) | d709b008-1cb9-43fd-bc8d-1279e3fa5c18 Netherlands (NL) | 22f0053f-2639-46a3-a188-3b06554e5a5e Sweden (SE) | 0dc0bae3-1a43-4bc0-b7df-b4bf195e4cee Poland (PL) | 54f748b4-f266-445d-af06-0def80345fa7 Germany (DE) | 287778dc-3cb1-4402-afd3-2dfa5979c5ee Norway (NO) | 2dcee700-3990-43cc-8508-de2cabcb8991 Denmark (DK) | 489bf38e-b3b1-4385-bb54-cfbc0468a6de Finland (FI)
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
EAN
8015644655440
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
210 mm
Product Net Height
268 mm
Product Net Depth / Length
154 mm
Product Net Weight
9.7 kg
Package Level 1 Units
1 piece
Package Level 1 Width
280 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
11.2 kg
Package Level 1 EAN
8015644655440
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
2000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 77 W
Rated Current (In)
1600 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Uninterrupted Current (Iu)
1600 A
Release
PR232/P-LSI
Release Type
EL
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0055
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39121100
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front-terminal fixed design simplifies wiring and front-access maintenance. Business Impact: Reduces panel depth requirements and speeds commissioning, while ensuring reliable, accessible wiring for service checks. Application: Ideal for 3P 690 V distribution panels and transformer feeders. | Feature: PR232/P-LSI electronic release delivers precise, fast tripping with high selectivity. Business Impact: Improves fault discrimination and minimizes downstream downtime in critical DC or AC feeders. Application: Suitable for heavy-load MCCBs in motor control centers and protection zones. | Feature: High fault-current handling with Ics up to 85 kA and Icu up to 85 kA at common voltages. Business Impact: Enables safe interruption of large fault currents without compromising system integrity. Application: Essential in transformer protection and heavy industrial installation bases. | Feature: Durability and efficiency with 2000 electrical cycles, 10000 mechanical cycles, and 77 W per pole power loss. Business Impact: Extends service life, reduces maintenance cycles, and lowers energy waste. Application: Long-term assets like data centers and manufacturing lines benefit from predictable performance. | Feature: Regulatory and compatibility support with RoHS, REACH, SCIP, EPD notes, and front-terminal FIXED mounting. Business Impact: Simplifies compliance, procurement, and installation with clear documentation. Application: Suitable for compliant, modern industrial installations and cross-site rollouts.
Get a Quick Quote for a ABB 1SDA062995R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA062995R1?
Enquire Now
FAQs
This MCCB uses fixed front-terminal connections that simplify wiring and front-access servicing. Ensure adequate clearance for front access, proper torque on terminal screws, and alignment with the panel cutout. Verify panel mounting orientation matches the device’s front-terminal footprint to avoid contact or clearance issues during maintenance.
Key specs include rated current of 1600 A, rated operational voltage of 690 V AC, and short-circuit interruption capability (Ics/Icu) up to 85 kA depending on voltage. The 3P configuration and PR232/P-LSI release enable fast, selective tripping, reducing fault impact on transformers and feeders in industrial plants.
Yes. It carries CE declarations and IEC standards alignment, along with SCIP, RoHS, REACH, and CMRT documentation in the product spec. DoC and GL/ST certifications are available, supporting regulatory filings, safe disposal, and responsible material reporting for sustainable operations.
Absolutely. The 1SDA062995R1 is designed for Tmax T7 applications, with a PR232/P-LSI release well-suited for precise protection in 3P fixed-breaker configurations. This ensures compatibility with Tmax T7 panels and enables consistent trip characteristics across the protection scheme.
With 2000 electrical cycles and 10000 mechanical cycles, the device offers long-term reliability and reduced replacement frequency. A low power loss of 77 W per pole helps lower energy costs, while front-terminal design speeds inspections and reduces maintenance downtime, contributing to lower total cost of ownership over the asset lifecycle.