ABB 1SDA062997R1 Moulded Case Breaker - IEC 690V/85kA
Part Number: 1SDA062997R1
Quick Summary
ABB 1SDA062997R1 Moulded Case Breaker provides reliable overcurrent protection for large-scale electrical installations. Engineers often confront downtime from unexpected faults and escalating maintenance costs in high-energy environments. This device carries CE conformity, IEC standards compliance, and RoHS/REACH declarations, ensuring safe, global deployment. Designed for Tmax T7 systems, it delivers robust protection with front-terminal accessibility that speeds installation and service, while its 3P 1600 A rating supports demanding distribution needs and reduces the need for parallel devices in industrial plants.
Product Information
Extended Description
1SDA062997R1 ABB: C.BREAKER TMAX T7S 1600 FIXED THREE-POLE WITH FRONT TERMINALS AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR332/P-LI R 1600
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
EAN
8015644655464
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
210 mm
Product Net Height
268 mm
Product Net Depth / Length
154 mm
Product Net Weight
9.7 kg
Package Level 1 Units
1 piece
Package Level 1 Width
280 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
11.2 kg
Package Level 1 EAN
8015644655464
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
2000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 77 W
Rated Current (In)
1600 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Uninterrupted Current (Iu)
1600 A
Release
PR332/P LI
Release Type
EL
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0055
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39121100
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: The 3P 1600 A rating combined with fixed front terminals enables high-current protection in compact enclosures, reducing the number of devices needed and saving panel space in industrial plants. Application: large motor drives and transformer protection in substations. Feature → Accessible maintenance → Application: Front-terminal design with a lever-operating mechanism simplifies testing, replacement, and commissioning, minimizing downtime during routine maintenance in control rooms and switchgear housings. Feature → Release performance → Application: PR332/P LI solid-state release delivers precise coordination with Tmax T7 protection schemes, improving selective tripping in complex feeder networks. Feature → Compliance backbone → Application: RoHS and REACH declarations, plus CE conformity and IEC standards, ensure procurement alignment with global procurement policies and reduce regulatory risk in multinational projects. Feature → Durability and lifecycle → Application: Electrical durability of 2000 cycles and mechanical durability of 10000 cycles support long service life in continuous operation environments such as manufacturing lines and processing plants. Feature → Safety and capability → Application: 8 kV rated impulse withstand and 1000 V insulation support safe operation in mixed voltage distributions and high-energy environments, enabling reliable protection of critical assets while meeting industry best practices. Feature → Packaging and logistics → Application: Verified packaging and EAN details streamline warehouse handling, shipping accuracy, and inventory control for distributors and system integrators.
Get a Quick Quote for a ABB 1SDA062997R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA062997R1?
Enquire Now
FAQs
The unit uses fixed front terminals designed for front-access installations, compatible with common switchgear and panelboard enclosures used in industrial facilities. Its 3P construction and front-terminal arrangement simplify mounting in tight spaces, while maintaining required clearances for safe operation and efficient maintenance.
Key ratings include a rated current of 1600 A, rated operational voltage of 690 V AC, rated insulation voltage of 1000 V, and a rated impulse withstand voltage of 8 kV. Short-circuit capability is up to 85 kA (Ics) across applicable voltages, with an Icw of 20 kA for 1 second and an uninterrupted current of 1600 A.
Yes. The device carries the CE Declaration of Conformity, adheres to IEC standards for performance and safety, and complies with RoHS and REACH regulations. CMRT and TSCA declarations are also available, supporting global procurement and regulatory requirements.
It is well-suited for Tmax T7 protection schemes in transformer and generator protection, distribution boards in manufacturing facilities, and other high-energy industrial power systems. The 3P 1600 A rating and front-terminal design make it ideal for reliable protection in demanding environments.
Electrical durability is rated at 2000 cycles and mechanical durability at 10000 cycles (60 cycles/hour). Plan for periodic inspection and replacement based on load profiles and fault history. The front-terminal design facilitates quick replacement, reducing downtime during routine servicing and upgrades.