ABB 1SDA063004R1 Moulded Case Circuit Breaker - PR331 LSIG

Part Number: 1SDA063004R1
Manufacturer
ABB
Part number
1SDA063004R1

Quick Summary

ABB 1SDA063004R1 Moulded Case Circuit Breaker protects medium-voltage distribution in industrial environments. When uptime is critical, you need a reliable, front-terminal four-pole design that handles 1600 A without compromising protection. This device is CE declared with RoHS and REACH compliance, plus SCIP registrations, aligning with IEC standards for safe, sustainable operation. With 690 V AC operational voltage, 1600 A rated current, and 8 kV impulse withstand, it delivers dependable protection across demanding applications. This aligns with our customers' focus on safety, reliability, and total lifecycle cost reduction. Ideal for Tmax T7 panels, distribution boards, and high-current motor feeders, this breaker helps maintain uptime, ensures compliance, and simplifies procurement.

Product Information

Extended Description

1SDA063004R1 ABB: C.BREAKER TMAX T7S 1600 FIXED FOUR-POLE WITH FRONT TERMINALS AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR331/P-LSIG R 1600
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
17a3b28d-9bb2-4b0e-8379-120a0807fb7c Italy (IT)
Simplified SCIP
2da94dab-c1a3-49b7-ada5-3b386e65af75 Germany (DE) | 1d7e49d2-521e-43c3-a8fa-07fe13981546 Poland (PL) | e39d1600-8a28-4a08-9523-104ed6b04be0 Norway (NO) | 1b98cd05-0461-470f-b757-12dfea5afea4 Netherlands (NL) | fac78540-c403-422c-83e3-b97e79631341 Poland (PL) | 1bc0b4e1-536b-4d2f-a259-a5c5b830cd90 France (FR) | 2960d033-9545-4d4d-b676-c8d4224f3a2c Sweden (SE) | 10fa285d-7ffc-41d6-a0da-25c3362c2957 Germany (DE) | 8f43c049-5ac7-454b-bf33-85e867fbe321 Germany (DE) | f7cffda4-0d38-45d7-a6c4-49516f3e88d6 France (FR) | a30b9b17-1b04-4d78-8bc3-acfbfb1f883f Netherlands (NL) | 01bc387a-95be-4ce8-8803-6729c5bfcd08 Spain (ES) | fb482673-2dec-48fb-88d2-677032fafebc Estonia (EE) | 8ab9390e-ea8e-4f1e-bc72-23a61c9a49ec Greece (GR) | 0e09a96e-10a6-4dc8-8c3e-6972837a88a7 Portugal (PT) | c735aef0-ff77-4417-aca1-b2143348d9d3 Bulgaria (BG) | a762645f-9185-4d8b-b264-a1c176b6737c Sweden (SE) | 206d4ef7-328a-45b9-b503-30e86ed61616 Netherlands (NL) | 14377f91-f709-4c92-ad9c-94ae89abd609 Netherlands (NL) | 4d98ecb6-52d2-4134-adcd-e3050aee523e Czech Republic (CZ) | 505658cc-baba-4232-a6cd-eaf59636b1eb Croatia (HR) | 3d9e3231-1ac9-4989-859a-b5bf5cdedcce Poland (PL) | 51e6d3a4-e034-421f-9f34-a43ac158d111 Germany (DE) | d4508bf4-281f-4ee3-90c0-a8f2f502c7a4 Germany (DE) | 21f77668-88ae-45e6-86f4-081a22e15837 Finland (FI) | 77fa5cf6-7d97-4e0c-9001-9b4f3969fc7a Netherlands (NL) | cddd1588-70d0-4aed-bc29-3ce5a26d354e Denmark (DK)
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
EAN
8015644655532
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
280 mm
Product Net Height
268 mm
Product Net Depth / Length
154 mm
Product Net Weight
17.737 kg
Package Level 1 Units
1 piece
Package Level 1 Width
360 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
14 kg
Package Level 1 EAN
8015644655532
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
2000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 77 W
Rated Current (In)
1600 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Uninterrupted Current (Iu)
1600 A
Release
PR331/P LSIG
Release Type
EL
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0055
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39121100
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Four-pole construction at 1600 A rating delivers robust protection across phase-to-phase and phase-to-ground faults. The four-pole design with front terminals and a lever operating mechanism ensures reliable tripping and straightforward maintenance, reducing downtime during inspections and replacements in high-energy distribution panels. Release PR331/P LSIG provides a precise, industry-standard trip curve, improving selective coordination in multi-breaker installations and lowering the risk of unnecessary outages. Application: used in Tmax T7 protective schemes in manufacturing lines and transformer stations. High fault current capability ensures reliable protection for feeders and busbars, with Ics up to 85 kA and Icu up to 85 kA depending on voltage, and Icw of 20 kA for 1 s, enhancing safety in 690 V systems. RoHS, REACH, and SCIP compliance mitigate regulatory risk and simplify end-of-life handling. Durable mechanics and limited maintenance requirements reduce lifecycle costs, while the compact footprint and fixed-front connections support straightforward retrofits into existing switchgear. Electrical durability of 2000 cycles and mechanical durability of 10000 cycles at 60 cycles per hour translate to longer service life and lower maintenance frequency. Weight at 17.737 kg, dimensions of 280 mm width x 268 mm height x 154 mm depth, and front-terminal accessibility streamline installation and service in industrial environments.

Get a Quick Quote for a ABB 1SDA063004R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA063004R1? Enquire Now

FAQs

The 1SDA063004R1 uses fixed front terminals and a four-pole format compatible with Tmax T7 configurations. Its 280 × 268 × 154 mm footprint fits common MCCB spaces, and the front-access design simplifies mounting, wiring, and testing. Verify enclosure clearance and torque specifications per the official installation manual during retrofits.
Key specs include a rated current of 1600 A, rated insulation voltage Ui of 1000 V, rated operational voltage Uo of 690 V AC, and an impulse withstand voltage of 8 kV. Short-circuit ratings reach up to 85 kA with Icw rated at 20 kA for 1 s. The device is a 4P unit with PR331/P LSIG release.
Yes. Its 4P configuration, high Icu/Ics ratings, and 690 V operation make it suitable for transformer protection and high-current feeders. The PR331/P LSIG release supports selective coordination in Tmax T7 schemes, helping minimize nuisance outages in transformer and distribution applications.
The unit carries CE conformity, RoHS and REACH declarations for circuit breakers, SCIP registration for responsible end-of-life handling, and IEC standards alignment. Additional declarations include a GL certificate and DoC, supporting compliance across EU and global procurement requirements.
Electrical durability is rated at 2000 cycles and mechanical durability at 10000 cycles at 60 cycles per hour. With 77 W power loss per pole, the design reduces energy waste and maintenance frequency, contributing to higher uptime and lower total cost of ownership in continuous operation environments.