ABB 1SDA063016R1 Moulded Case Circuit Breaker protects motor and switchgear circuits from overloads in industrial power systems. This solution delivers reliable protection in demanding environments while simplifying panel design and maintenance. Many teams struggle with incorrect trip settings and downtime during maintenance. By combining front-terminal access with a stored-energy operating mechanism, it reduces service time and minimizes human error during inspections. Designed to IEC standards with CE conformity and RoHS/REACH declarations, it supports global procurement and compliance. Leveraging the Tmax T7 family, this MCCB delivers scalable protection for large-draw equipment and critical loads, enabling engineers to specify one device for diverse protection roles while maintaining fault-clearance performance and lifecycle cost savings.

Product Information

Extended Description

1SDA063016R1 ABB: C.BREAKER TMAX T7S 1600 FIXED THREE-POLE WITH FRONT TERMINALS AND STORED ENERGY OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR332/P-LSIRc R 1600
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
EAN
8015644655655
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
210 mm
Product Net Height
268 mm
Product Net Depth / Length
178 mm
Product Net Weight
11 kg
Package Level 1 Units
1 piece
Package Level 1 Width
280 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
12.5 kg
Package Level 1 EAN
8015644655655
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7M
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Electrical Durability
2000 cycle | 60 cycles per hour
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 77 W
Rated Current (In)
1600 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 50 kA | (400 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 40 kA | (690 V AC) 30 kA
Rated Uninterrupted Current (Iu)
1600 A
Release
PR332/P-LSIRc
Release Type
EL
Short-Circuit Performance Level
S
Standards
IEC
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
1SDC210015D0201
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
GL Certificate
1SDL000163R0055
Instructions and Manuals
1SDC210015D0201
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Three-pole configuration with a 1600 A rated current and fixed front terminals delivers high-throughput, dependable protection for demanding motor feeders. The built-in stored-energy operating mechanism reduces trip times and eliminates manual resetting delays, improving safety during commissioning and quarterly tests. This arrangement is ideal for large manufacturing lines where space is at a premium and service windows are tight. Release PR332/P-LSIRc enables precise, reliable tripping and improved selective isolation within complex switchgear architectures, reducing nuisance trips and extending equipment life. Rated for 690 V AC and 1000 V insulation, with 8 kV rated impulse withstand and 85 kA Ics, the device provides robust surge protection for critical loads and ensures reliable fault clearance in diverse industrial environments. Material compliance including RoHS and REACH declarations, plus CMRT integration, streamline global sourcing and regulatory adherence, lowering procurement risk. Front-terminal design and a compact footprint simplify panel retrofits and new installations, while compatibility with Tmax T-series panels ensures seamless integration into ABB protection ecosystems. The product’s main type, SACE Tmax T, and suitability for T7M configurations position it as a scalable solution for varying protection needs across large facilities, reducing total cost of ownership.

Get a Quick Quote for a ABB 1SDA063016R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA063016R1? Enquire Now

FAQs

Installation begins with confirming a three‑pole arrangement and proper alignment of the front-terminal terminals. Use the stored-energy mechanism to safely set the device, then secure the MCCB to the panel frame with the prescribed torque values. Verify wiring polarity and ensure compatible busbar spacing. Refer to the related 1SxD and 1SDC documentation for step‑by‑step instructions.
Key ratings include three poles (3P) with a 1600 A nominal current, 690 V AC rated operational voltage, 1000 V rated insulation voltage, 8 kV rated impulse withstand voltage, and 85 kA short‑circuit breaking capacity (Ics). It also features a 20 kA short-time withstand current (Icw) and a 1600 A uninterrupted current (Iu). The release is PR332/P-LSIRc.
Yes. The product carries a CE declaration of conformity and RoHS/REACH compliance declarations. These certifications support global procurement and simplify regulatory approvals across multiple regions, reducing the time and cost of compliance during installation and commissioning.
Ideal for large motor feeders, transformer protection, and main distribution panels in industrial plants. It is designed to handle high fault currents with reliable coordination within Tmax T-series ecosystems. The front-terminal, stored-energy design supports quick servicing, making it suitable for facilities prioritizing uptime and easy retrofits in evolving protection schemes.
Maintenance benefits include faster operation and testing due to the stored-energy mechanism and accessible front terminals, reducing downtime. Durability specs show 10000 mechanical cycles and 2000 electrical cycles, supporting long service life. Combined with high current capability and compatibility with existing Tmax T components, this reduces total cost of ownership and spare-part spend over the device lifecycle.