ABB 1SDA064872R1 Moulded Case Circuit Breaker - UL489
Part Number: 1SDA064872R1
Quick Summary
Moulded Case Circuit Breaker is ABB's 1SDA064872R1 designed to protect power distribution in industrial facilities. Engineers often struggle with downtime and equipment damage from fault currents, so reliable trip protection is critical. This unit carries UL recognition, a CE declaration, and CSA compatibility, supporting compliant panel builds and global deployments. With front-terminal accessibility and a 1200 A rating, it scales for Tmax T systems and demanding motor loads, delivering business value through safer, smarter protection. Choosing a MCCB with documented RoHS and REACH compliance helps reduce risk across procurement and lifecycle management. It also aligns with end-of-life recycling programs for a sustainable industrial footprint.
Product Information
Extended Description
1SDA064872R1 ABB: C.BREAKER TMAX T7S 1200 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR332/P-LSI R 1200
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
Order Code US and Canada
T7S1200RW
EAN
8015644677718
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
210 mm
Product Net Height
268 mm
Product Net Depth / Length
154 mm
Product Net Weight
9.7 kg
Package Level 1 EAN
8015644677718
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable For
T7
Suitable for Product Class
Moulded Case Circuit Breakers
Version
F
Mechanical Durability
10000 cycle | 60 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 47 W
Rated Current (In)
1200 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
630 V AC
Rated Uninterrupted Current (Iu)
1200 A
Release
PR332/P LSI
Release Type
EL
Short-Circuit Performance Level
S
Standards
UL
Sub-type
T7
Terminal Connection Type
Fixed Circuit-Breakers | Front
Test Voltage Max (Utest)
3500 V
Interrupting Rating acc. to UL489
(240 V AC) 65 kA | (480 V AC) 50 kA | (600 V AC) 25 kA
Data Sheet, Technical Information
9AKK105713A5947
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T7
Instructions and Manuals
Tmax. T Generation - Low voltage molded case circuit breakers up to 1200 A - UL 489 and CSA C22.2 Standard
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: UL489 interrupting rating delivers high fault current protection; Business Impact: minimizes downtime and equipment damage by reliably interrupting faults; Application: suitable for Tmax T distribution panels in heavy-duty environments. Feature: 3P configuration with 1200 A rated current and 630 V AC operating voltage; Business Impact: supports high-load feeders and scalable protection without oversizing the system; Application: motor drives and critical power circuits. Feature: Front-terminal design with fixed circuit-breaker mounting; Business Impact: simplifies wiring and maintenance, reducing installation time; Application: serviceable panels and retrofit projects. Feature: RoHS and REACH compliance plus CMRT and TSCA declarations; Business Impact: streamlines global procurement and regulatory accreditation; Application: multinational facilities and compliant panel shops. Feature: Mechanical durability rated at 10000 cycles; Business Impact: longer service life reduces replacement cycles and maintenance costs; Application: high-cycle protection in production lines. Feature: Product family fit for T7 and Tmax Tmax T series; Business Impact: ensures compatibility and scalable protection; Application: new and retrofit projects across power distribution zones.
Get a Quick Quote for a ABB 1SDA064872R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA064872R1?
Enquire Now
FAQs
The 1SDA064872R1 is a fixed 3-pole MCCB with front terminals. To install, mount the unit in a compatible panel, connect conductors to the front terminals using appropriate torque per ABB guidelines, and ensure correct alignment with the lever-actuated release PR332/P LSI. Front-access wiring enables quicker wiring checks and easier maintenance in busy switchgear environments.
According to UL489 ratings, this device provides 65 kA interrupting capability at 240 V, 50 kA at 480 V, and 25 kA at 600 V. These figures help protect downstream equipment and feeders, reducing the risk of cascading failures in medium and high-current installations.
Yes. The product is designed for SACE Tmax T protection schemes and is compatible with T7 applications. Its 3P configuration, 1200 A rated current, and front-terminal design make it suitable for motor control centers and distribution panels requiring robust overload and short-circuit protection.
This MCCB features UL recognition and a CE Declaration of Conformity, plus RoHS and REACH compliance. Additional regulatory considerations include CMRT for conflict minerals and TSCA for chemical substances. These certifications simplify global procurement and ensure your panels meet common international standards.
With an industrial mechanical durability rating of up to 10000 cycles and a front-access design, maintenance intervals are extended and service times reduced. The 1200 A rating supports handling peak loads without oversizing, lowering total cost of ownership through fewer replacements, easier servicing, and consistent protection across production cycles.