ABB 1SDA065397R1 Moulded Case Circuit Breaker - Tmax Ts3N 150 UL/CSA
Part Number: 1SDA065397R1
Quick Summary
ABB 1SDA065397R1 Moulded Case Circuit Breaker protects electrical circuits in industrial control panels and machinery. When wiring tightens or schedules slip, you need a breaker that trips accurately and documents clearly. This model aligns with UL/CSA requirements and CE conformity, while TMF magnetic release supports fast, reliable protection. Engineers benefit from front-terminal wiring, compact footprint, and documented installation guidance that minimizes commissioning time. Its current range is 25–500 A and fixed three-pole configuration suits power distribution in automation panels. The product's dimensions (105 mm width, 170 mm height, 103.5 mm depth) help predict enclosure fit, while 1.6 kg weight reduces handling effort during installation.
Product Information
Extended Description
1SDA065397R1 ABB: C.BREAKER TMAX Ts3N 150 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 25-500 A
EAN
8015644682132
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
105 mm
Product Net Height
170 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
1.6 kg
Package Level 1 EAN
8015644682132
Product Main Type
SACE Tmax
Product Name
Moulded Case Circuit Breaker
Data Sheet, Technical Information
Tmax. T Generation - Low voltage molded case circuit breakers up to 1200 A - UL 489 and CSA C22.2 Standard
Declaration of Conformity - CE
EC Declaration of Conformity Tmax Ts3
Instructions and Manuals
Installation instructions Ts3
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Fixed three-pole construction with front terminals accelerates wiring and minimizes field errors, delivering faster panel assembly and reduced commissioning time. The compact 105 mm width and 170 mm height fit tightly packed control cabinets, while the 103.5 mm depth preserves enclosure space. This configuration is ideal for automation panels where reliable three-phase protection and straightforward wiring are essential for uptime. TMF thermomagnetic release provides fast, predictable tripping under overload or short circuit, protecting motors and sensitive loads while limiting arc flash exposure during maintenance. The current range of 25–500 A covers a wide spectrum of machine sizes without component swaps, reducing spare parts inventory. In automated lines, predictable trip behavior translates to reduced downtime and improved process continuity. UL 489 and CSA C22.2 compliance, together with the CE declaration, simplify regulatory approvals for panel builders and OEMs. The Tmax Ts3N family offers performance up to 1200 A, giving engineers a scalable protection strategy that aligns with modern automation architectures. This broad compatibility helps standardize protection across multiple panels and projects. Dimensions of 105 mm width, 170 mm height, and 103.5 mm depth provide a repeatable footprint for enclosure planning, while a mass of about 1.6 kg eases handling during installation. Front-terminal access reduces wiring complexity and supports safer, neater terminal conductors. The device is designed for quick replacement during maintenance or upgrades without significant rewiring. Installation guidance Ts3, mounting compatibility, and documented manuals help contractors meet project schedules and reduce risk of misalignment. The moulded-case construction offers durable performance in harsh industrial environments, while the front terminals simplify field wiring checks. This product supports retrofit projects in existing automation cells, enabling faster upgrades, easier diagnostics, and improved fault isolation.
Get a Quick Quote for a ABB 1SDA065397R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA065397R1?
Enquire Now
FAQs
Choose a suitable enclosure with enough clearance for a fixed three-pole breaker. The front-terminal design simplifies wiring, and the unit’s 105 mm by 170 mm footprint fits standard panel spaces. Use the specified torque on terminals per Ts3 installation instructions and connect according to the field wiring diagram. Its 25–500 A rating supports a wide range of circuits, with TMF providing predictable protection.
Key specs include a current range of 25–500 A, fixed three-pole configuration, front terminals for easy wiring, and TMF thermomagnetic release for fast tripping. The unit weighs 1.6 kg and has compact dimensions of 105 mm width by 170 mm height by 103.5 mm depth. It aligns with UL 489 and CSA C22.2 standards, and carries CE conformity.
Yes. The Tmax Ts3N family is designed for low-voltage protection in automation panels, offering reliable current interruption up to 500 A per unit and scalable protection up to 1200 A across the family. Fixed three-pole construction supports three-phase machines, while front terminals enable rapid wiring and straightforward maintenance in busy production lines.
The device carries UL 489/CSA C22.2 compliance and CE declarations, ensuring regulatory alignment for North American and European installations. WEEE categorization and installation manuals further support environmental handling and safe, documented commissioning during modernization or new builds.
Front-terminal wiring reduces installation time and reduces wiring errors, delivering faster commissioning. The TMF release minimizes nuisance trips, lowering unplanned downtime. A standardized current range (25–500 A) and documented Ts3 installation guidance help lower spare-part inventories and simplify training, contributing to a clearer path to faster ROI in panel builds and automation upgrades.