Quick Summary

ABB 1SDA065462R1 is a moulded case circuit breaker designed for low-voltage protection in distribution panels. When space is tight and uptime matters, you need a reliable device that combines fast, selective tripping with straightforward maintenance. The Tmax Ts3H family aligns with UL 489 and CSA C22.2 standards and is CE conformant, supporting regulatory compliance across North America and Europe. Front-terminal access and a compact footprint streamline installation for panel builders, while standardized ratings enable scalable protection across multiple switchgear configurations. This model covers a broad current range and integrates smoothly with Tmax TMF trip units, offering predictable performance and reduced maintenance costs for automation and energy-management projects.

Product Information

Extended Description

1SDA065462R1 ABB: C.BREAKER TMAX Ts3H 150 UL/CSA FIXED TWO-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 150-1500 A
EAN
8015644682781
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
105 mm
Product Net Height
170 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
1.6 kg
Package Level 1 EAN
8015644682781
Product Main Type
SACE Tmax
Product Name
Moulded Case Circuit Breaker
Data Sheet, Technical Information
Tmax. T Generation - Low voltage molded case circuit breakers up to 1200 A - UL 489 and CSA C22.2 Standard
Declaration of Conformity - CE
EC Declaration of Conformity Tmax Ts3
Instructions and Manuals
Installation instructions Ts3
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature → Business Impact → Application: Front terminals provide easier wiring access and faster commissioning, reducing installation time and potential for wiring errors in dense panels. This translates to lower field labor costs and improved reliability in critical automation rooms where downtime costs are high. Feature → Thermal-magnetic TMF release provides precise, coordinated tripping under overloads and short circuits, enhancing safety and continuity of service for manufacturing lines and critical process equipment. Application: Use in SACE Tmax protected distributions to meet industry safety standards while maintaining uptime. Feature → Fixed two-pole configuration simplifies protection schemes in compact switchgear, enabling consistent protection across feeders with minimal spatial footprint. Application: Ideal for regional panels, machine rooms, and packaging lines where space and predictability matter. Feature → Product data includes dimensions (105 mm width, 170 mm height, 103.5 mm depth) and weight (1.6 kg), aiding accurate cabinet planning and inventory. Application: Helps OEMs plan layouts and shipping for large-scale installations. Feature → UL 489, CSA C22.2, and CE declarations ensure regulatory compliance across markets, reducing certification risk for panel builders and integrators. Application: Facilitates cross-border projects and faster time-to-market for automation solutions. Feature → EAN 8015644682781 and MOQ of 1 piece support efficient procurement and stocking for distributors and service teams. Application: Enables straightforward sourcing for ongoing maintenance and upgrades.

Get a Quick Quote for a ABB 1SDA065462R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA065462R1? Enquire Now

FAQs

When installing the ABB 1SDA065462R1, ensure front-terminal access for easier wiring and quicker terminal checks. The unit is a fixed two-pole design, with dimensions 105 mm wide, 170 mm high, and 103.5 mm deep, weighing 1.6 kg. Plan panel cutouts and clearance to accommodate the device without hindering bus connections, and verify mounting orientation per the installation instructions to maintain proper arc venting and labeling.
This MCCB supports UL 489 and CSA C22.2 standards and carries CE conformity, indicating compliance with North American and European electrical safety requirements. These certifications matter because they reduce regulatory risk, simplify customer acceptance tests, and align with common procurement specs for industrial automation projects and panel manufacturing across multiple regions.
The model supports a current range from 150 A to 1500 A, as indicated by the TMF R specification. This broad range makes it suitable for mid- to large-load feeders in industrial panels, motor feeders, and distribution boards. When selecting, match the continuous operating current and anticipated fault levels to avoid nuisance trips while ensuring robust protection during faults.
Yes. The product is part of the SACE Tmax family and designed to integrate with Tmax trip units and protection schemes. Its fixed two-pole configuration and front-terminal design support straightforward integration into standard Tmax-based switchgear, enabling scalable protection architectures for manufacturing lines, process control, and energy distribution systems.
engineers should plan for the device dimensions (105 mm width, 170 mm height, 103.5 mm depth) and 1.6 kg weight to ensure cabinet fit and ease of handling during installation. The front-terminal design reduces wiring complexity, aiding periodic inspection and maintenance. Regularly verify the thermal-magnetic release operation using standard test procedures to maintain reliable protection and minimize unplanned outages.