ABB 1SDA065469R1 Moulded Case Circuit Breaker - UL/CSA Ts3L
Part Number: 1SDA065469R1
Quick Summary
ABB 1SDA065469R1 Moulded Case Circuit Breaker provides reliable overcurrent protection for low-voltage power circuits in industrial control panels. In busy environments, miswiring or delayed fault isolation can cause downtime and safety risks. This device carries CE conformity via EC Declaration of Conformity, UL/CSA certification for safety, and WEEE category 5 compliance, reinforcing regulatory readiness. The front-terminal, fixed three-pole design with a TMF thermomagnetic release covers a wide current range and supports fast, secure wiring. These features translate into reduced installation time, predictable trip behavior, and lower total cost of ownership across motor feeders and distribution panels.
Product Information
Extended Description
1SDA065469R1 ABB: C.BREAKER TMAX Ts3L 150 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 50-500 A
EAN
8015644682859
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
105 mm
Product Net Height
170 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
1.6 kg
Package Level 1 EAN
8015644682859
Product Main Type
SACE Tmax
Product Name
Moulded Case Circuit Breaker
Data Sheet, Technical Information
Tmax. T Generation - Low voltage molded case circuit breakers up to 1200 A - UL 489 and CSA C22.2 Standard
Declaration of Conformity - CE
EC Declaration of Conformity Tmax Ts3
Instructions and Manuals
Installation instructions Ts3
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Three-pole fixed configuration with front terminals streamlines wiring and reduces installation time in control panels. The standard footprint enables rapid integration into existing MCCs and machine cabinets, and helps maintenance teams rewire efficiently during upgrades. In practice, this means fewer wiring mistakes during commissioning and shorter outage windows for line start-ups. TMF thermomagnetic release delivers precise overload and short-circuit protection for motor feeders and distribution circuits. By combining thermal and magnetic elements, it limits fault energy and improves selectivity, which translates to safer startups and reduced equipment stress. This protection is particularly valuable in conveyors, pumps, and presses where duty cycles are high. Current rating range from 50 to 500 A gives designers a single MCCB family option across multiple panel sizes, reducing spare parts inventories. The integration with SACE Tmax family simplifies engineering data sheets and supplier onboarding. With a fixed three-pole design, you can rely on consistent trip performance across phases, improving electrical reliability. Compact dimensions—105 mm wide, 170 mm high, and 103.5 mm deep—along with a 1.6 kg weight, support easy enclosure fitting and retrofits in space-constrained cabinets. Front terminals enable straightforward field wiring, while clear labeling for the EAN, product type, and main type accelerates documentation and asset management. The result is faster commissioning and simpler future upgrades. UL 489 and CSA C22.2 compatibility, CE declarations, and WEEE category 5 compliance ensure regulatory alignment and safe end-of-life handling. The data sheet summarizes Tmax Ts3L performance, while installation instructions Ts3 guide proper mounting and electrical connections. End users benefit from consistent supplier documentation, reducing risk during audits and procurement.
Get a Quick Quote for a ABB 1SDA065469R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA065469R1?
Enquire Now
FAQs
For new panel builds, select a three-pole MCCB with front terminals to simplify wiring in compact enclosures. Verify the 105 mm width and 170 mm height fit your DIN rail or panel cutouts, and follow the Ts3 installation guidelines. Ensure correct phasing and labeling, and plan space for servicing tools to facilitate future maintenance.
The Ts3L integration provides a TMF thermomagnetic release that protects against overloads and short circuits. Rated from 50 to 500 A, it offers predictable, fast tripping with phase-to-phase coordination in three-pole configurations. This combination improves fault localization, reduces arc energy exposure, and preserves downstream equipment in motor feeders and distribution circuits.
Yes. The fixed 3P design with front terminals and TMF release is well-suited for motor feeders and control-panel protection. It supports rapid wiring, reliable start-up sequencing, and consistent trip behavior across phases. Its Tmax Ts3L lineage provides scalable protection for a range of motor loads, making it a dependable choice for conveyors, pumps, and machine tools.
This MCCB is UL 489/CSA C22.2 compliant with safety certifications, accompanied by an EC Declaration of Conformity for CE, and WEEE category 5 compliance. Documentation includes the Tmax data sheet and installation instructions Ts3, aligning procurement with regulatory and end-of-life requirements for industrial environments.
The front-terminal wiring and robust thermomagnetic protection reduce commissioning time and maintenance complexity, lowering downtime. A broad 50–500 A range minimizes spare parts stocking, while ISO/IEC-aligned documentation simplifies audits. Collectively, these factors contribute to lower total cost of ownership, longer equipment life, and more predictable energy management in dynamic production lines.