ABB 1SDA065470R1 Moulded Case Breaker - UL/CSA TMF
Part Number: 1SDA065470R1
Quick Summary
ABB 1SDA065470R1 Moulded Case Circuit Breaker provides reliable overcurrent protection for industrial power distribution panels and machine control systems. This solution helps prevent downtime by quickly interrupting fault currents in demanding environments. Users often face tight panel spaces and complex wiring; a compact, front-terminal three-pole design eases retrofits and reduces install time. The Tmax Ts3L family carries UL 489 and CSA C22.2 certifications, with CE conformity available for cross-border deployments. By combining TMF thermal-magnetic release with a defined current range (60–600 A) and proven mechanical life, this MCCB supports safer operation, lower maintenance costs, and improved plant uptime, while aligning with broader industrial procurement strategies.
Product Information
Extended Description
1SDA065470R1 ABB: C.BREAKER TMAX Ts3L 150 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 60-600 A
EAN
8015644682866
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
105 mm
Product Net Height
170 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
1.6 kg
Package Level 1 EAN
8015644682866
Product Main Type
SACE Tmax
Product Name
Moulded Case Circuit Breaker
Data Sheet, Technical Information
Tmax. T Generation - Low voltage molded case circuit breakers up to 1200 A - UL 489 and CSA C22.2 Standard
Declaration of Conformity - CE
EC Declaration of Conformity Tmax Ts3
Instructions and Manuals
Installation instructions Ts3
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Three-pole fixed construction with front terminals and TMF release simplifies wiring, speeds commissioning, and improves fault discrimination in compact control panels. The configuration minimizes visible wiring routes and reduces field misconnection risks, delivering tangible time-and-cost savings for panel builders and service teams. It is ideal for machine controllers, switchboards, and power feeders in manufacturing environments where space is at a premium. The current range of 60–600 A gives you scalable protection for a broad set of loads, from feeders to motor circuits. This flexibility reduces the need for multiple device variants, lowers inventory costs, and enables quicker on-site replacements when line demand changes. Applications include conveyors, presses, and automation cabinets where reliable interruption performance is critical. UL 489 and CSA C22.2 certification along with CE declaration of conformity demonstrate regulatory readiness for North American and European projects, simplifying supplier qualification, streamlining compliance audits, and supporting cross-border deployments without redesign. The Tmax Ts3L family is designed for consistent performance in harsh industrial environments. The compact footprint—105 mm net width, 170 mm height, and 103.5 mm depth—facilitates denser panel layouts and easier retrofits in existing enclosures. At about 1.6 kg, the device remains manageable for field installation while preserving robustness through a molded case construction. Front-terminal accessibility further reduces wiring time and enables straightforward testing during commissioning. As part of the SACE Tmax lineage, this MCCB benefits from proven reliability and service-life advantages inherent to molded case technology. Engineers gain predictable thermal performance and straightforward diagnostics, supporting proactive maintenance and improved plant uptime. In practical terms, the combination of performance specs and certified safety translates to lower total cost of ownership.
Get a Quick Quote for a ABB 1SDA065470R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA065470R1?
Enquire Now
FAQs
To install the ABB 1SDA065470R1, power down the panel, mount the unit in a suitable enclosure, and connect conductors to the front terminals as per the Ts3L installation instructions. Verify the three-pole alignment, provide secure torque for terminal connections, and ensure proper clearance and cooling. Use the TMF release for accurate tripping and perform a functional test after wiring to confirm correct operation.
Yes. With a 60–600 A current range and a three-pole fixed configuration, this MCCB provides reliable motor feeder protection in industrial environments. The TMF thermal-magnetic release helps prevent nuisance trips from temporary inrush, while the front-terminal design supports straightforward wiring and testing in motor control cabinets and panel feeders.
The device complies with UL 489 and CSA C22.2 for North American safety, and it carries a CE Declaration of Conformity for regional deployments. Data sheets and installation instructions are provided by ABB to help ensure regulatory compliance and consistent performance across projects.
Yes. The front-terminal, three-pole fixed design is optimized for dense panel layouts, enabling quicker wiring and simplified testing during commissioning. The compact dimensions and 1.6 kg weight make handling easier in tight enclosures, while TMF protection maintains robust fault interruption characteristics.
Tmax Ts3L MCCBs offer proven reliability through molded-case technology, with predictable thermal performance and durable mechanical life. This translates to lower maintenance costs, reduced replacement risk, and improved plant uptime, especially in high-demand automation environments where consistent protection and diagnostic clarity matter.