ABB 1SDA065482R1 Moulded Case Circuit Breaker - UL/CSA Ts3L
Part Number: 1SDA065482R1
Quick Summary
Moulded Case Circuit Breaker from ABB 1SDA065482R1 protects low-voltage distribution panels in industrial automation. Engineers often contend with wiring complexity, downtime, and inconsistent tripping in demanding environments; this MCCB streamlines front-terminal wiring, delivers precise thermomagnetic protection, and reduces nuisance trips. It aligns with UL 489 and CSA C22.2 standards, and carries a CE Declaration of Conformity for Tmax Ts3, along with installation instructions to support compliant deployments. Designed for SACE Tmax Ts3L ecosystems, it integrates with existing control schemes while offering scalable protection for future panel expansions and reliability improvements across manufacturing lines.
Product Information
Extended Description
1SDA065482R1 ABB: C.BREAKER TMAX Ts3L 150 UL/CSA FIXED TWO-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 35-500 A
EAN
8015644682989
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
105 mm
Product Net Height
170 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
1.6 kg
Package Level 1 EAN
8015644682989
Product Main Type
SACE Tmax
Product Name
Moulded Case Circuit Breaker
Data Sheet, Technical Information
Tmax. T Generation - Low voltage molded case circuit breakers up to 1200 A - UL 489 and CSA C22.2 Standard
Declaration of Conformity - CE
EC Declaration of Conformity Tmax Ts3
Instructions and Manuals
Installation instructions Ts3
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature: Front-terminal two-pole design with TMF thermomagnetic release enables quick, low-torque wiring and reliable protection. Business Impact: Reduces installation time and wiring errors, lowers commissioning costs, and improves safety with predictable trip curves. Application: Ideal for control panels and motor feeders in machine rooms where space is tight and reliability matters. Feature: Moulded case construction with a compact 105 mm width and 170 mm height footprint supports dense panel layouts. Business Impact: Maximizes usable panel space, simplifies layout planning, and supports modular add-ons for future capacity. Application: Distribution boards and compact switchgear assemblies. Feature: Front-terminal wiring and a 103.5 mm depth simplify on-site maintenance and fault diagnosis. Business Impact: Easier servicing minimizes downtime, improves technician efficiency, and enhances safety during live checks. Application: Routine inspections in panel boards and MCC rooms. Feature: TMF (thermomagnetic release) provides fast, selective tripping for overloads and short circuits. Business Impact: Improves system protection against arc-flash risks, reduces collateral damage, and meets protection coordination goals. Application: Motor control centers and power distribution networks. Feature: SACE Tmax Ts3L family compatibility with UL 489 and CSA C22.2 standards, plus CE DoC. Business Impact: Ensures regulatory compliance, broadening market acceptance and streamlining supplier qualification. Application: Global installations requiring certified low-voltage protection devices. Feature: Product data supports easy procurement and lifecycle planning with clear dimensions, weight, and tariff details. Business Impact: Improves BOM accuracy and total cost of ownership through predictable logistics. Application: Panel fabrication, electrical engineering, and procurement workflows.
Get a Quick Quote for a ABB 1SDA065482R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA065482R1?
Enquire Now
FAQs
For new panel builds, prioritize front-terminal wiring access and space for two-pole mounting. The device fits compact layouts (105 mm wide, 170 mm high) and supports straightforward wiring with TMF protection. Use the installation instructions Ts3 to ensure correct torque, terminal sizing, and correct phasing to maximize performance and meet regulatory requirements.
The ABB 1SDA065482R1 is a two-pole Moulded Case Circuit Breaker with thermomagnetic TMF release designed for low-voltage distribution. It is part of the Tmax Ts3L family and supports front-terminal wiring, with dimensions and weight published (105 mm W, 170 mm H, 103.5 mm D, 1.6 kg). It aligns with UL 489 and CSA C22.2 standards for reliable protection against overloads and short circuits.
Yes. The MCCB is certified under UL 489 and CSA C22.2, and it carries a CE Declaration of Conformity for Tmax Ts3. This ensures regulatory compliance across North American and European markets and supports certified integration into standard low-voltage protection schemes.
Tmax Ts3L MCCBs are recommended for low-voltage panel protection in distribution boards, motor control centers, and machine control panels. They provide reliable two-pole protection with front-terminal wiring, enabling efficient panel layouts and safer maintenance while meeting industry standards for electrical safety and protection coordination.
Maintenance aims for periodic inspection of terminals and testing the thermal-magnetic trip function. The front-terminal design reduces wiring complexity, cutting commissioning time and downtime during servicing. ROI comes from enhanced protection reliability, lower fault-related downtime, and compliance with UL/CSA CE standards, prolonging equipment life and reducing unexpected repair costs.