ABB 1SDA065483R1 Moulded Case Breaker - UL/CSA Ts3
Part Number: 1SDA065483R1
Quick Summary
ABB 1SDA065483R1 Moulded Case Circuit Breaker protects electrical distribution in control panels and industrial installations. Engineers frequently confront nuisance trips due to transient overloads, and wiring complexity during installation or upgrades across multiple feeders. This model carries UL/CSA recognition for Tmax Ts3, CE conformity, and front-terminal TMF release compatibility, supported by a data sheet and DoC. Its compact 105 mm width, 170 mm height, and 103.5 mm depth enable easier panel layouts, while the 1.6 kg weight aids handling and installation efficiency. In practice, you gain faster commissioning, fewer field errors, and improved compliance with the SACE Tmax platform. This makes it a reliable choice for industrial automation and control system upgrades.
Product Information
Extended Description
1SDA065483R1 ABB: C.BREAKER TMAX Ts3L 150 UL/CSA FIXED TWO-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 40-500 A
EAN
8015644682996
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
105 mm
Product Net Height
170 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
1.6 kg
Package Level 1 EAN
8015644682996
Product Main Type
SACE Tmax
Product Name
Moulded Case Circuit Breaker
Data Sheet, Technical Information
Tmax. T Generation - Low voltage molded case circuit breakers up to 1200 A - UL 489 and CSA C22.2 Standard
Declaration of Conformity - CE
EC Declaration of Conformity Tmax Ts3
Instructions and Manuals
Installation instructions Ts3
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature: UL/CSA Tmax Ts3L 2-pole with front terminals. Business Impact: Ensures regulatory compliance and simplifies cross-border procurement for North American and European projects. Application: Suitable for control panels and distribution boards where front-terminal wiring saves time during wiring and maintenance. Feature: Thermomagnetic release TMF R 40-500 A. Business Impact: Delivers selective coordination and robust short-circuit protection, reducing downtime and collateral damage after faults. Application: Industrial distribution and machine control circuits with variable load profiles. Feature: Compact footprint and weight. Business Impact: Easier panel density planning, faster installation, and safer handling on site. Application: New builds and retrofit projects in enclosures with limited space (105 mm width, 170 mm height, 103.5 mm depth; 1.6 kg). Feature: Product compatibility with Tmax Tmax Ts3 family. Business Impact: Streamlines design consistency and spare parts availability across multi-line installations. Application: System design reviews and procurement for mixed automation architectures. Feature: Certifications and documentation. Business Impact: Supports compliance workflows, reduces auditing time, and accelerates approvals with CE DoC, DoC, and installation instructions. Application: Global deployments requiring formal documentation and regulatory alignment.
Get a Quick Quote for a ABB 1SDA065483R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA065483R1?
Enquire Now
FAQs
The ABB 1SDA065483R1 is a two-pole Moulded Case Circuit Breaker with front-terminal access designed for Tmax Ts3 installations. It aligns with UL 489 and CSA C22.2 standards and integrates smoothly into control panels that require front-side wiring and straightforward service access. Its dimensions and weight support efficient panel layout, reduced installation time, and easier field maintenance, making it suitable for both new builds and retrofit projects.
This device features a thermomagnetic release TMF rated to handle 40–500 A, delivering reliable overload protection with magnetic short-circuit interruption. The two-pole design supports coordinated protection across paired circuits, enabling safer startup and operation of motors and feeders. The TMF release helps maintain selectivity in multi-circuit panels and reduces nuisance trips during transient faults.
Yes. The unit carries UL/CSA recognition for Tmax Ts3 and is CE-declared with an EC Declaration of Conformity, enabling compliant use in North American and many global installations. Installation instructions Ts3 provide guidelines for safe mounting, and DoC documentation supports regulatory filings. For mixed environments, ensure panel compatibility with front-terminal wiring and the Tmax Ts3L specifications.
The product ships with essential documentation including the Data Sheet for Tmax generation, the EC Declaration of Conformity for Tmax Ts3, and installation instructions Ts3. Additional references cover safety and installation procedures. This suite supports compliance audits, technical reviews, and end-user verification during commissioning and maintenance activities.
Upgrading to the Tmax Ts3L two-pole unit can reduce downtime due to its reliable thermomagnetic protection and front-terminal wiring that speeds commissioning. The compact footprint simplifies panel upgrades, while global certification supports faster procurement. Over the lifecycle, expected benefits include lower maintenance costs, fewer field wiring errors, and improved system reliability in critical automation applications.