ABB 1SDA065489R1 Moulded Case Circuit Breaker - UL/CSA TMF
Part Number: 1SDA065489R1
Quick Summary
ABB 1SDA065489R1 is a moulded case circuit breaker used to protect electrical distribution and motor circuits. End users often face nuisance trips and costly downtime when protection is mis-specified or poorly installed. This unit adheres to key standards such as UL and CSA for low‑voltage protection, CE conformity, and documented Tmax Ts3L 150 A performance with TMF magnetic releases. With front terminals for easy wiring and a compact footprint, it delivers reliable protection in space-constrained panels. The product supports fast installation and streamlined maintenance, helping procurement teams standardize on a single Tmax family while ensuring compliance and operational reliability.
Product Information
Extended Description
1SDA065489R1 ABB: C.BREAKER TMAX Ts3L 150 UL/CSA FIXED TWO-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 100-1000 A
EAN
8015644683054
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
105 mm
Product Net Height
170 mm
Product Net Depth / Length
103.5 mm
Product Net Weight
1.6 kg
Package Level 1 EAN
8015644683054
Product Main Type
SACE Tmax
Product Name
Moulded Case Circuit Breaker
Data Sheet, Technical Information
Tmax. T Generation - Low voltage molded case circuit breakers up to 1200 A - UL 489 and CSA C22.2 Standard
Declaration of Conformity - CE
EC Declaration of Conformity Tmax Ts3
Instructions and Manuals
Installation instructions Ts3
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature → Business Impact → Application: 2-pole design with front terminals enables straightforward wiring and panel integration, reducing installation time and termination errors on motor control centers and distribution panels. This improves changeover efficiency and minimizes downtime in manufacturing lines. Feature → TMF thermomagnetic release provides overcurrent and short-circuit protection with fast, selective tripping, lowering the risk of cascade failures and improving system reliability for critical processes. Application: suitable for new builds and panel refurbishments where uptime is essential and safety regulations demand robust protection. Feature → Ts3L 150 frame and a current range of 100–1000 A align with Tmax family compatibility, enabling standardized spares and simplified maintenance planning. Application: large MCCBs in switchgear assemblies across industrial plants benefit from reduced lifetime costs and consolidated procurement. Feature → UL/CSA and CE declarations ensure regulatory compliance, reducing qualification cycles for commissioning and enabling smoother audits. Application: projects in North America and Europe seeking certified protection devices with documented technical data. Feature → Compact footprint and documented dimensions (105 mm width, 170 mm height, 103.5 mm depth) support efficient panel layouts and faster retrofits. Application: modernization projects and retrofit programs where space is at a premium. Feature → Front-access serviceability and clear installation instructions (Ts3) shorten maintenance windows and improve technician productivity. Application: field service teams working in constrained enclosures can perform checks without full disassembly.
Get a Quick Quote for a ABB 1SDA065489R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA065489R1?
Enquire Now
FAQs
Install the ABB 1SDA065489R1 as a two-pole MCCB with front terminals to simplify wiring and wiring access. Ensure panel cutouts, clearance, and busbar alignment match the Ts3L frame specifications. Use manufacturer installation instructions Ts3 for torque guidance and proper mounting to minimize nuisance trips and ensure regulatory compliance.
It features a Ts3L 150 frame, 2-pole configuration, TMF thermomagnetic release, and a current range from 100 to 1000 A. It is listed under UL and CSA standards with CE conformity, and comes with a Data Sheet detailing Tmax performance up to 1200 A in low-voltage molded case circuits.
Yes. The 1SDA065489R1 is designed for motor and distribution panel protection, offering selective, fast tripping and front-terminal wiring. Its TMF release and Tmax family compatibility support reliable motor protection schemes and streamlined panel organization, reducing downtime and improving system resilience.
The device carries UL 489 and CSA C22.2 certifications as part of the Tmax data set, plus a CE Declaration of Conformity for Tmax Ts3. Installation instructions Ts3 are provided, and it is associated with a Datasheet covering Tmax generation and WEEE categorization for compliance considerations.
Front-terminal access reduces wiring and service time during maintenance. Standardization within the Tmax Ts3 family simplifies spares and training, lowering total cost of ownership. Reliability improves due to TMF protection, minimizing unexpected outages and optimizing uptime across mission-critical manufacturing processes.