ABB 1SDA065727R1 Moulded Case Circuit Breaker - CE Certified

Part Number: 1SDA065727R1
Manufacturer
ABB
Part number
1SDA065727R1

Quick Summary

ABB 1SDA065727R1 Moulded Case Circuit Breaker provides reliable overcurrent protection for high-current power distribution in industrial facilities. Engineers often grapple with unexpected faults and downtime when protection devices lack fast, clear diagnostics. The Tmax T8L family is backed by CE conformity, RoHS compliance, and REACH declarations, plus SCIP registrations to meet modern regulatory demands. This solution also offers a front-terminal, fixed-mount design that accelerates installation and reduces wiring errors, while delivering robust protection for critical loads. In short, it combines safety, compliance, and long-term cost efficiency for electrical distribution systems.

Product Information

Extended Description

1SDA065727R1 ABB: C.BREAKER TMAX T8L 2000 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC PR332/P-LSIG R 2000
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
a42a1fff-3fef-4b9d-9244-56d4a0822e8f Italy (IT)
Simplified SCIP
4c2d3002-1174-4f80-a72d-c3ad7c2a7e8a Germany (DE) | ca9b3199-56b1-4bd8-b7d4-1316ca78e34d Poland (PL) | f627283e-23a3-43a6-b2eb-b9c9e7451514 Spain (ES) | 1a3b519c-ac90-42f6-a621-52dc31f09afc Belgium (BE) | eedc793f-ca8f-42f7-83b5-17edb4a288d1 Norway (NO) | 58d54ecb-e63d-4581-a903-82287c15ed87 Finland (FI) | 54fe6590-b531-45d2-9362-0783807f3caa Denmark (DK) | a3821e94-3138-4931-9815-d39f45a2c938 Germany (DE) | 21ee9adf-211e-4365-afad-f5203e653c55 Czech Republic (CZ) | 79a547f2-1c60-4fa1-94c2-68d0dae13b6e Poland (PL) | 1a43a672-64f6-4a85-ae4f-61c80b1e2ae0 Sweden (SE) | 3a966a8d-2510-4de1-ab53-65b6077242f0 Poland (PL) | f622bbe3-6b5b-4db7-9c21-eb93bdffec57 Portugal (PT) | 717e1812-dee0-4802-85f6-96de24b15e59 France (FR) | fa184e60-862f-4378-8775-84f87ca3a934 Germany (DE) | 8749d3c6-485d-457e-9b0a-333452c267f2 Sweden (SE) | 20e4ff75-c955-459e-98bf-fb0c2b1ac483 France (FR) | ba566e4c-db4d-4279-8d00-f1f6ff9fe2a3 Croatia (HR) | 75606990-65ab-47a3-89aa-98cb703db3c0 Hungary (HU) | 49d1d09f-a33c-4fee-ad20-e3a731046b69 Germany (DE) | 1c20d25c-aea4-4d22-9e89-508e07e3ce05 Netherlands (NL) | c5d0c9a6-df48-4a28-985f-07d6c3eea91f Germany (DE) | e9c6744d-e585-42c8-b588-f59c43afa46b Estonia (EE) | f016dfac-0e5a-4f29-af0a-63a8e8f00261 Greece (GR) | 815ef825-dc43-44c4-aa32-95fbb7385e8e Hungary (HU) | 67076b28-073b-4e9b-8686-e9136429932d Bulgaria (BG) | 83aa96fe-ec0f-4ec6-84fa-41ea02a0a6ba Belgium (BE)
Environmental Information
Product Environmental Information Tmax T8 | Breakers - Packaging disposal information
Order Code US and Canada
T8LFD3GS000000XX
EAN
8015644686345
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
427 mm
Product Net Height
382 mm
Product Net Depth / Length
282 mm
Product Net Weight
79 kg
Package Level 1 Units
1 piece
Package Level 1 Width
525 mm
Package Level 1 Height
475 mm
Package Level 1 Depth / Length
695 mm
Package Level 1 Gross Weight
89 kg
Package Level 1 EAN
8015644686345
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Electrical Durability
4500 cycle | 20 cycles per hour
Mechanical Durability
15000 cycle | 60 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 46 W
Rated Current (In)
2000 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 85 kA | (400 V AC) 85 kA | (415 V AC) 85 kA | (440 V AC) 85 kA | (500 V AC) 65 kA | (690 V AC) 50 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 40 A
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 85 kA | (400 V AC) 85 kA | (415 V AC) 85 kA | (440 V AC) 85 kA | (500 V AC) 65 kA | (690 V AC) 50 kA
Rated Uninterrupted Current (Iu)
2000 A
Release
PR332/P LSIG
Release Type
EL
Short-Circuit Performance Level
L
Standards
IEC
Sub-type
T8
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
Tmax. T Generation - Low voltage molded case circuit breakers up to 1200 A - UL 489 and CSA C22.2 Standard
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T8
Wiring Diagram
Wiring diagram T8
Instructions and Manuals
1SDC210033D0202
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: 3P fixed-front terminal design simplifies installation and wiring verification, reducing installation time by enabling straightforward mounting and easier field connections; ideal for panel builders and OEMs deploying compact MCCs or transformer feeder sections. Feature → Business Impact → Application: 2000 A rated current and 690 V AC rated operational voltage enable protection of large feeders and high-current circuits in data centers, manufacturing lines, and substations, improving system reliability and reducing unplanned downtime. Feature → Business Impact → Application: PR332/P LSIG electronic release offers selective tripping and faster response, improving protective coordination and minimizing downstream disturbances in complex power networks. Feature → Business Impact → Application: RoHS, REACH, and SCIP compliance ensure regulatory alignment and sustainability, simplifying procurement and reducing risk for global projects. Feature → Business Impact → Application: Mechanical durability of 15000 cycles and electrical durability of 4500 cycles translate to lower maintenance costs and longer service life in high-switching environments such as motor feeders and critical load sections. Feature → Business Impact → Application: Clear dimensional and connectivity specs (427 mm W x 382 mm H x 282 mm D, 79 kg) support accurate space planning and safer handling in modular switchgear assemblies. These attributes collectively support efficiency gains, regulatory compliance, and a lower total cost of ownership for industrial electrical protection.

Get a Quick Quote for a ABB 1SDA065727R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA065727R1? Enquire Now

FAQs

Install with fixed-front terminals as designed, ensuring panel cutout and mounting clearances accommodate the 427 mm width, 382 mm height, and 282 mm depth. Use appropriate torque settings for terminal connections and verify compatibility with 690 V AC systems. The front-terminal design minimizes wiring complexity and speeds up commissioning in MCCs and transformer feeders.
This device is rated for 2000 A nominal current and 690 V AC operational voltage, with a rated insulation voltage of 1000 V and a rated impulse withstand of 8 kV. It provides a rated short-circuit breaking capacity up to 85 kA and a short-time withstand current of 40 A for 1 s, suitable for high-demand power distributions.
Yes. With 3P configuration, fixed-front terminals, and Tmax T8 release, it supports transformer protection schemes and large motor feeder applications. Its high Ics ratings and 85 kA capacity enable effective coordination with upstream protection devices, while the LSIG release enhances selective tripping and system stability.
The 1SDA065727R1 line carries a CE Declaration of Conformity for Tmax T8, along with RoHS and REACH declarations. It also aligns with SCIP registrations, TSCA considerations, and WEEE/GHS classifications, helping meet global environmental and safety requirements across multinational projects.
Electrical durability is rated at 4500 cycles and mechanical durability at 15000 cycles, reducing replacement frequency in high-switching environments. The front-terminal design simplifies periodic checks and maintenance, while robust insulation and high-current capabilities contribute to lower total cost of ownership in continuous operation environments.