ABB 1SDA065730R1 Moulded Case Circuit Breaker - PR331/P LSIG
Part Number: 1SDA065730R1
Quick Summary
ABB 1SDA065730R1 is a high-current moulded case circuit breaker for 690 V power distribution and switchgear protection. It delivers four-pole reliability with a front-terminal configuration and a solid-state release (PR331/P LSIG), designed to excel in demanding industrial environments. Engineers often struggle with secure wiring access and accurate trip signaling under heavy loads; this device simplifies installation while improving fault visibility. The unit carries CE conformity, RoHS and REACH declarations, along with an EC Declaration of Conformity Tmax T8, ensuring global regulatory compliance. For procurement, its 2000 A rating and robust 85 kA short-circuit performance translate into reduced downtime, fewer spares, and lower lifecycle costs in critical facilities requiring dependable protection.
Product Information
Extended Description
1SDA065730R1 ABB: C.BREAKER TMAX T8L 2000 FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC PR331/P-LSIG R 2000
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
f1496d50-1510-4b75-8a2e-585441c6f635 Italy (IT)
Simplified SCIP
a0b97a3b-f96a-45d0-935d-112bb696b6e5 Germany (DE) | 06348a89-ad7d-4cbd-80e9-2d2fd3837b56 Portugal (PT) | 0ca76354-d726-42c3-a6cb-be541e6c55a5 Poland (PL) | ead5fd0f-e8d0-44a3-847c-df3bdc7890f7 Czech Republic (CZ) | 2dc17159-8da6-479a-b35b-7eeebc09dc6c Denmark (DK) | f3c44f12-a037-4d9d-8a6d-1f4c58eb95ae Germany (DE) | 52114297-de62-4518-bb77-f7b844d39031 Netherlands (NL) | 0b1c70c0-4ec2-4dd8-9d0c-f6087e1e26f6 Germany (DE) | e144746f-d840-47e6-adf4-723d20539089 Hungary (HU) | 36c02456-55f0-42d9-a254-3ce782580c4d Germany (DE) | 852a8dba-2b8c-42ac-aaf6-e3f878b7407a France (FR) | 99f1ff3e-553c-4b72-95bc-2383764ef235 Croatia (HR) | 2f0da64f-0f79-4d1c-a6f0-6be8457dcbc6 Finland (FI) | 4451c1bc-ba29-41d4-8b79-f6836562a773 Norway (NO) | 864bf96f-db05-4ead-acc7-61592c47ea7a Belgium (BE) | b0698050-97a5-456d-8f57-e90605e3cf02 Spain (ES) | 875cbc8f-eb7c-43d4-9186-94f7a644fff1 Hungary (HU) | 19b98b6c-b2fe-4805-91f5-fa96966406b0 Bulgaria (BG) | f5506638-9e15-4503-a459-12a2999a5e09 Belgium (BE) | f17a13c2-b534-411f-aeec-7bbb63a6be5d Greece (GR) | 6dc952d4-27f8-4cdc-ab01-51646754bc25 Poland (PL) | 7102c3ff-1af1-4a3a-a72a-275c2ff9950a Germany (DE) | c0651810-ea9c-48bc-94da-3aba11eea222 Estonia (EE) | ead884db-d0fe-4329-9d02-3a94b13a61e6 Sweden (SE) | a8a8e127-0efa-4fda-99d3-e226831f0547 Poland (PL) | 4875c429-da64-418c-8a07-62879a96d37f Sweden (SE) | ba70f738-c747-4cd0-ad98-aeef7f44d5eb France (FR)
Environmental Information
Product Environmental Information Tmax T8 | Breakers - Packaging disposal information
Order Code US and Canada
T8LFD4GE000000XX
EAN
8015644686376
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
553 mm
Product Net Height
382 mm
Product Net Depth / Length
282 mm
Product Net Weight
12.5 kg
Package Level 1 Units
1 piece
Package Level 1 Width
650 mm
Package Level 1 Height
475 mm
Package Level 1 Depth / Length
695 mm
Package Level 1 Gross Weight
14 kg
Package Level 1 EAN
8015644686376
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Electrical Durability
4500 cycle | 20 cycles per hour
Mechanical Durability
15000 cycle | 60 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 46 W
Rated Current (In)
2000 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 85 kA | (400 V AC) 85 kA | (415 V AC) 85 kA | (440 V AC) 85 kA | (500 V AC) 65 kA | (690 V AC) 50 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 40 A
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 85 kA | (400 V AC) 85 kA | (415 V AC) 85 kA | (440 V AC) 85 kA | (500 V AC) 65 kA | (690 V AC) 50 kA
Rated Uninterrupted Current (Iu)
2000 A
Release
PR331/P LSIG
Release Type
EL
Short-Circuit Performance Level
L
Standards
IEC
Sub-type
T8
Terminal Connection Type
Fixed Circuit-Breakers | Front
Data Sheet, Technical Information
Tmax. T Generation - Low voltage molded case circuit breakers up to 1200 A - UL 489 and CSA C22.2 Standard
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T8
Wiring Diagram
Wiring diagram T8
Instructions and Manuals
1SDC210033D0202
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4934 >> 4 Pole Non-Interchangeable Trip Electronic Circuit Breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Front-terminal fixed design paired with a PR331/P LSIG release provides tool-free wiring access and precise trip signaling, reducing installation time and field errors. Application: 4P Tmax T systems in switchgear and power distribution networks. High current rating of 2000 A enables protection of large feeders and transformer feeders, reducing the number of parallel devices and improving overall system reliability. Data centers and process plants with high-load profiles benefit from consolidated protection. Rated operational voltage of 690 V AC and insulation of 1000 V ensure compatibility with mid-voltage networks, offering flexibility for panel upgrades and equipment migrations in industrial facilities. Short-circuit performance up to 85 kA (Icu/Ics) at relevant voltages and a high 8 kV impulse withstand provide robust fault clearing and enhanced safety margins during peak transients. Compliance and lifecycle advantages include RoHS, REACH, CMRT, SCIP declarations, and CE conformity, along with low heat loss of 46 W per pole—reducing regulatory risk, maintenance costs, and energy waste. Front-terminal design and a 4P configuration support quick replacement and modular retrofit, minimizing downtime during maintenance and upgrades in panel builders and service teams.
Get a Quick Quote for a ABB 1SDA065730R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA065730R1?
Enquire Now
FAQs
Install using the 4P front-terminal configuration per the wiring diagram, ensuring proper lug sizing and torque specifications. Mount the unit per panel guidelines, attach conductors to the front terminals, and verify the PR331/P LSIG release connections. Use the front-access design to test or replace the release without removing the device from the busbar footprint.
Key ratings include 2000 A rated current, 690 V AC rated operational voltage, 1000 V rated insulation voltage, 8 kV rated impulse withstand, and up to 85 kA short-circuit breaking capacity (Icu/Ics) depending on voltage. The device features 4 poles and a power loss of about 46 W per pole, suitable for high-demand protection schemes.
Yes. With 85 kA short-circuit capability, 690 V operating voltage, and 4P front-terminal construction, it is well-suited for transformer protection and large feeder circuits in industrial plants. The PR331/P LSIG release adds reliable electronic signaling, enhancing protection coordination in switchgear assemblies.
The ABB Tmax T8 family, including this model, carries CE conformity (EC Declaration of Conformity Tmax T8), RoHS compliance, and REACH declarations. Additional documentation includes CMRT for conflict minerals, SCIP registration details, and related environmental declarations.
The high 2000 A rating reduces the need for parallel devices, lowering upfront hardware counts. Front-terminal wiring speeds installation and service, while low per-pole heat loss (46 W) decreases cooling load. Together these factors reduce downtime, spare parts, and energy costs, delivering measurable lifecycle savings on regulated, high-load installations.