ABB 1SDA065734R1 Moulded Case Breaker - Tmax T8 3200 A

Part Number: 1SDA065734R1
Manufacturer
ABB
Part number
1SDA065734R1

Quick Summary

Moulded Case Circuit Breaker ABB 1SDA065734R1 protects power distribution in demanding industrial environments. Engineers often struggle to balance high current capacity with fast fault isolation and straightforward installation in retrofit panels. This device carries CE certification with a Declaration of Conformity for Tmax T8, RoHS and REACH declarations, and SCIP listings to support compliant sourcing and supply-chain transparency. With a 3200 A rated current, 690 V AC operation, and a fixed three-pole design with rear vertical terminals, it delivers robust protection without compromising panel space or serviceability. In practice, this MCCB integrates smoothly into ABB ecosystems and Tmax T8 family applications, offering predictable performance, easier maintenance, and lower lifecycle costs for industrial facilities and critical infrastructure.

Product Information

Extended Description

1SDA065734R1 ABB: C.BREAKER TMAX T8L 3200 FIXED THREE-POLE WITH TERMINALS REAR VERTICAL AND SOLID-STATE RELEASE IN AC PR331/P-LSI R 3200
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
db2031c8-2853-4efa-8807-ab758c431566 Italy (IT)
Simplified SCIP
bfd1ad5c-a3b6-48ac-9dd8-86b3a0b9f2e4 Estonia (EE) | 3bc0ca5b-3583-41e3-8427-ad3e12f4a642 Poland (PL) | 7f3d28de-ef2b-48f9-9036-4a6b59d37082 Netherlands (NL) | 656dc445-bfe3-4bbb-9052-484df1aff54b Germany (DE) | 65c2542d-5a9e-49cd-bd6b-3d8738c2b43d Czech Republic (CZ) | bf24e933-7485-4ec2-98eb-d955ed094ad2 Germany (DE) | f6142761-404d-4cac-ae37-08298a2e2b63 Denmark (DK) | 5596e67d-56d6-4c53-bbfe-0fb2673de591 Croatia (HR) | cfe2cd0c-674e-4f71-b000-2b26ead497eb Bulgaria (BG) | d9cf884c-c1d1-4d58-acc6-e3637d970df7 Belgium (BE) | 1b129249-0981-4cdc-a822-08682c3cba00 Hungary (HU) | f3200e19-d6bf-42b5-b87d-c48a506deb51 Germany (DE) | 61b00cc3-8623-4822-9fdc-1da2eb274828 France (FR) | 9c1f5a23-dddb-4d14-ae5e-0db0aba48918 France (FR) | 7e78e95f-d411-4fed-8171-2982ee7fb86d Sweden (SE) | ba2a9f63-4b1a-4ff7-8949-f4ace367abdb Germany (DE) | 6441b05c-23e9-414a-9bc9-8758559ad547 Sweden (SE) | d0e8e042-1d83-473c-b2a1-a52bfe53f9d1 Portugal (PT) | d7244f4e-be3b-4407-a686-9828e89d5efb Poland (PL) | 6dc7bcc7-1344-422c-8d89-9ba16e8728fe Greece (GR) | e9d5527f-7820-4c73-99f1-8d7a72fa49d2 Hungary (HU) | bace73cb-f2b6-4d6b-af87-aa01dc6d7a17 Finland (FI) | 78af6b07-e04c-46e2-aedc-335fcb8c2964 Norway (NO) | 37a3df1e-43d1-4d76-a7c6-ff625492f1b9 Germany (DE) | 0b364162-b04c-4967-8be9-011ecd80f0a8 Spain (ES) | 98770a9f-b1ad-4ebf-bc30-25baa5c8e3de Belgium (BE) | dc93d005-8d8a-4a3d-be7d-17c4b28303a0 Poland (PL)
Environmental Information
Product Environmental Information Tmax T8 | Breakers - Packaging disposal information
Order Code US and Canada
T8LFF3JC000000XX
EAN
8015644686413
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
427 mm
Product Net Height
382 mm
Product Net Depth / Length
282 mm
Product Net Weight
94 kg
Package Level 1 Units
1 piece
Package Level 1 Width
525 mm
Package Level 1 Height
665 mm
Package Level 1 Depth / Length
695 mm
Package Level 1 Gross Weight
109 kg
Package Level 1 EAN
8015644686413
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Electrical Durability
3000 cycle | 20 cycles per hour
Mechanical Durability
15000 cycle | 60 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 117 W
Rated Current (In)
3200 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 85 kA | (400 V AC) 85 kA | (415 V AC) 85 kA | (440 V AC) 85 kA | (500 V AC) 65 kA | (690 V AC) 50 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 40 A
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (380 V AC) 85 kA | (400 V AC) 85 kA | (415 V AC) 85 kA | (440 V AC) 85 kA | (500 V AC) 65 kA | (690 V AC) 50 kA
Rated Uninterrupted Current (Iu)
3200 A
Release
PR232/P-LSI
Release Type
EL
Short-Circuit Performance Level
L
Standards
IEC
Sub-type
T8
Terminal Connection Type
Fixed Circuit-Breakers | Rear flat Vertical
Data Sheet, Technical Information
Tmax. T Generation - Low voltage molded case circuit breakers up to 1200 A - UL 489 and CSA C22.2 Standard
Declaration of Conformity - CE
EC Declaration of Conformity Tmax T8
Wiring Diagram
Wiring diagram T8
Instructions and Manuals
1SDC210033D0202
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Three-pole, fixed-mount MCCB with rear vertical terminals streamlines cabinet wiring and reduces installation time, cutting field labor costs while improving reliability in dense switchgear. The 3200 A rating and 690 V AC operating voltage provide ample headroom for large feeders and critical loads in manufacturing and infrastructure projects. The optional electronic release PR232/P-LSI delivers precise, fast tripping and improved selectivity within Tmax T8 families, helping minimize arc flash risk and unplanned downtime. With 85 kA short-circuit capacity (Ics/Icu) at multiple voltages and 8 kV impulse withstand, you gain robust protection for transformers, motors, and gensets in heavy industry. RoHS, REACH, SCIP, and CE declarations support regulatory compliance and sustainable sourcing. Rear-fixed terminals ease retrofit installations in existing enclosures and improve maintenance access. Mechanical durability of 15,000 cycles and electrical durability of 3,000 cycles translate to longer service life and lower total cost of ownership. Compatibility with ABB ecosystems and Tmax T8 release lines reduces engineering effort during panel upgrades and new builds, delivering faster time-to-protection and simplified procurement.

Get a Quick Quote for a ABB 1SDA065734R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA065734R1? Enquire Now

FAQs

This MCCB uses a fixed rear-terminal configuration with rear flat vertical terminals, designed for straightforward integration into existing switchgear and panel boards. The three-pole (3P) arrangement supports compact installation in limited spaces while maintaining reliable bus connections. Its compatibility with Tmax T8 ecosystems means you can standardize around ABB cabinets and wiring practices, reducing engineering time and minimizing mismatch risks during retrofit projects.
Key specs include a rated current of 3200 A, rated operational voltage of 690 V AC, and a rated impulse withstand voltage of 8 kV. It offers short-circuit protection up to 85 kA (Ics/Icu) across multiple voltages, an insulation voltage of 1000 V, and a rated uninterrupted current of 3200 A. The release is PR232/P-LSI, with a fixed, rear-terminal design suitable for high-current feeders.
The unit carries a CE Declaration of Conformity for Tmax T8, RoHS and REACH declarations, and SCIP listings to support compliant sourcing and supply-chain transparency. WEEE considerations, EU compliance, and TSCA-related declarations are acknowledged within the product data package, ensuring alignment with regulatory requirements in Europe and globally.
Ideal for high-current distribution in industrial facilities, data centers, and power distribution panels. It suits transformer and generator protection, large motor feeders, and switchgear upgrades where reliable 3P protection, fast fault clearing, and long service life are critical. The rear-terminal design simplifies retrofits in existing enclosures, while compatibility with Tmax T8 enhances coordination with other protection devices.
With mechanical durability rated at 15,000 cycles and electrical durability at 3,000 cycles, maintenance intervals can be extended with confidence in device reliability. The 117 W power loss per pole at rated operation reduces unnecessary energy waste, while robust short-circuit protection minimizes downtime and potential equipment damage, translating to lower total cost of ownership and improved uptime for mission-critical systems.