ABB 1SDA066141R1 Accessory - SOR-C A1-A2 480-525 Vac
Part Number: 1SDA066141R1
Quick Summary
ABB 1SDA066141R1 shunt opening release is a wired accessory that enables remote tripping for 480–525 V AC A1-A2 circuits. Engineers often struggle with ensuring reliable remote operation and seamless integration with existing A1/A2 control wiring in panel assemblies. This release complies with IEC standards and CE declarations, with RoHS and REACH compliance to support global manufacturing. The solution also aligns with TSCA reporting for North American supply chains, reducing compliance risk. Beyond safety and compliance, it delivers installation flexibility and predictable maintenance planning through standard weights, EAN packaging, and documented manuals. For procurement teams, the ABB Sace compatibility and straightforward wiring options offer tangible operational and cost benefits.
Product Information
Extended Description
1SDA066141R1 ABB: SHUNT OPENING RELEASE WIRED 480...525V AC A1-A2
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
KA2S1
EAN
8015644691332
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
0.12 kg
Package Level 1 Units
1 piece
Package Level 1 Gross Weight
0.14 kg
Package Level 1 EAN
8015644691332
Product Main Type
Accessories for FORMULA
Product Name
Accessory
Product Type
ACC
Suitable For
A1, A2
Configuration Type
Loose or configurable
Current Type
AC
Rated Voltage (Ur)
480 ... 525 V AC
Standards
IEC
Data Sheet, Technical Information
9AKK105713A5945
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
1SDC210032D0204
ETIM 8
EC002483 - Switch spool for power circuit breaker
ETIM 9
EC002483 - Switch spool for power circuit breaker
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370421
Voltage range compatibility delivers reliable remote tripping for 480-525 V AC A1-A2 circuits, reducing manual intervention and minimizing downtime in critical processes. This feature translates to higher system availability and safer shutdowns in production lines. The option of being loose or configurable provides installation flexibility, enabling seamless integration with existing control wiring and simplifying retrofits in legacy switchgear. The AC current type supports common industrial power architectures, while IEC standards and CE declarations ensure regulatory compliance across global deployments, lowering risk during audits. RoHS, REACH, CMRT, and TSCA declarations reinforce sustainability and global supply chain responsibility, supporting customer ESG goals and market access. Packaging, weight, and clear EAN data streamline logistics, procurement, and spare parts planning, reducing total cost of ownership over the asset lifecycle. Compatibility with FORMULA accessories and A1/A2 coil control means faster commissioning and reduced field adjustments, addressing common objections about installation time and compatibility.
Get a Quick Quote for a ABB 1SDA066141R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA066141R1?
Enquire Now
FAQs
The installation begins with verifying coil ratings and disconnecting power. Connect A1 and A2 to the control circuit, secure the release to the compatible ABB FORMULA housing, and route wiring according to the manufacturer’s 1SDC210032D0204 manual. After wiring, perform continuity checks and functional test per the 9AKK105713A5945 data sheet. Ensure compliance with local electrical codes and IEC standards during commissioning.
Yes. The 1SDA066141R1 is designed as a shunt opening release compatible with FORMULA line circuit breakers and A1-A2 control wiring. It supports loose or configurable installation and aligns with ABB Sace documentation, ensuring straightforward integration with existing ABB equipment and minimizing retrofit complexity.
Key specs include a rated voltage of 480 to 525 V AC, AC current type, and a connection to A1-A2 terminals. It is intended as a wired shunt release accessory for remote tripping in the FORMULA product ecosystem, with IEC standards alignment and CE/ RoHS/ REACH compliance for regulatory assurance.
The device carries RoHS information and declaration, REACH declaration, CMRT for conflict minerals, TSCA declaration, Environmental packaging information, and CE Declaration of Conformity reference. It also cites IEC standards and ABB data sheets for full traceability and audit readiness.
The shunt release enables rapid remote isolation, reducing mean time to trips during fault conditions, improving operator safety, and lowering maintenance costs through standardized wiring and documentation. Its compatibility with A1-A2 and FORMULA assemblies supports faster commissioning and reduces field rework.