ABB 1SDA066315R1 Shunt Opening Release - IEC60947-2 UL489
Part Number: 1SDA066315R1
Quick Summary
ABB 1SDA066315R1 shunt release for Tmax XT circuit breakers enables fast, reliable opening under control signals, ideal for decentralized protection schemes in industrial plants. Without a matched release for XT1–XT4, technicians face slower fault isolation, less predictable coordination with lockout/tagout procedures, and higher risk during maintenance windows. This device complies with IEC60947-2 and UL489, and ABB provides RoHS and REACH declarations along with environmental data for sustainable procurement. As a plug-in or loose configuration accessory with clear installation guidelines, it supports streamlined commissioning, reduced spare-part complexity, and better total cost of ownership.
Product Information
Extended Description
1SDA066315R1 ABB: SHUNT OPENING RELEASE 48-60V AC-DC XT1..XT4
Environmental Product Declaration - EPD
EPD Shunt opening releases Tmax XT XT1...XT4 (IT)
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
KXTASORC
E-Number (Norway)
4381317
EAN
8015644002237
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
0.102 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
110 mm
Package Level 1 Height
60 mm
Package Level 1 Depth / Length
140 mm
Package Level 1 Gross Weight
0.107 kg
Package Level 1 EAN
8015644002237
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT1, XT2, XT3, XT4
Suitable for Product Class
SACE Tmax XT
Configuration Type
Loose or configurable
Current Type
AC/DC
Order Multiple
1 piece
Rated Voltage (Ur)
48 ... 60 V AC | 48 ... 60 V DC
Standards
IEC60947-2 | UL489
Data Sheet, Technical Information
1SDC210100D0205 | 1SDC210099D0205
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
SOR/PS-SOR - Wired and non-wired opening release for XT1-XT2-XT3-XT4, Fixed/ Plug in CB
ETIM 8
EC002483 - Switch spool for power circuit breaker
ETIM 9
EC002483 - Switch spool for power circuit breaker
IDEA Granular Category Code (IGCC)
4879 >> Shunt release (for power circuit breaker)
Object Classification Code
Q
UNSPSC
39121601
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370421
XT family compatibility enables a single release across XT1 through XT4. This reduces SKU proliferation and simplifies stocking for parts common in Tmax XT protection schemes. Application: control cabinets, motor control centers, and process automation panels where space is constrained and fast circuit isolation is necessary. Voltage range of 48-60 V AC/DC provides flexibility across regions and supply variations, reducing inventory and cross-compatibility issues. Application: global manufacturing lines and multi-site facilities with XT1–XT4 devices. Compliance and environmental declarations (EPD, RoHS, REACH, CMRT, TSCA) simplify procurement and regulatory audits, ensuring sustained access to markets with strict supplier due diligence. Application: enterprise projects in regulated industries. Packaging and logistics details (0.102 kg net weight; box 1 piece; 110x60x140 mm) support predictable shipping and warehouse planning. Application: field deployment and large-scale installations where logistics speed matters. Robust IEC60947-2 UL489 standards alignment delivers safe, dependable operation in safety-critical roles. Application: high-energy distribution panels in utilities and heavy industry. This ABB accessory also offers flexible installation options and clear documentation, reducing training time for technicians and accelerating project timelines.
Get a Quick Quote for a ABB 1SDA066315R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA066315R1?
Enquire Now
FAQs
The 1SDA066315R1 is designed for XT1 through XT4 breakers and supports both loose and plug-in configurations. Use the KXTASORC order code for US/Canada. Verify 48-60 V AC/DC compatibility, and reference the standard wiring diagrams in the 1SDC210100D0205 data sheet. With XT1–XT4, you can streamline mounting, minimize wiring errors, and reduce commissioning time on control panels and switchgear.
Key specs include a rated voltage range of 48 to 60 V AC/DC,-compatible with AC/DC control signals. It adheres to IEC60947-2 and UL489 standards for circuit breakers, with RoHS and REACH declarations. Additional technical information is available in data sheets 1SDC210100D0205 and 1SDC210099D0205 to support reliability analysis and regulatory compliance during audits.
Yes. The release is designed for Tmax XT breakers (XT1–XT4) in industrial power distribution and process automation environments. Its robust standards alignment (IEC60947-2, UL489) and environmental declarations make it suitable for safety-critical panels, where fast, coordinated opening improves fault clearance and maintenance efficiency.
The release carries EPD documentation, RoHS and REACH declarations, and CMRT and TSCA reporting. It also aligns with CE declarations for circuit breakers and provides packaging disposal information. These declarations support sustainable procurement and help streamline supplier qualification and compliance audits across global supply chains.
By using a compatible XT1–XT4 release across multiple breakers, spare-parts stocking simplifies, reducing inventory costs. Its reliability lowers maintenance downtime, speeds fault isolation, and enhances protective coordination in switchgear. ABB’s documented standards and data sheets also reduce risk during audits, contributing to a favorable total cost of ownership over equipment life cycles.