ABB 1SDA066317R1 Shunt Opening Release - IEC60947-2 UL489

Part Number: 1SDA066317R1
Manufacturer
ABB
Part number
1SDA066317R1

Quick Summary

ABB 1SDA066317R1 Shunt Opening Release enables rapid, reliable tripping of Tmax XT breakers in industrial power systems. Many panels suffer from slow fault isolation or inconsistent release wiring, leading to costly downtime. It carries CE conformity, UL489 listing, and IEC60947-2 compliance, aligning with modern safety and interoperability standards. For engineers and procurement teams, the accessory simplifies installation in XT1–XT4 panels and supports RoHS/REACH compliance while reducing total cost of ownership. With a clear order code KXTASORE for US and Canada, compatibility is easier for global teams. Lightweight packaging and a net weight of 0.1 kg help reduce shipping and installation time.

Product Information

Extended Description

1SDA066317R1 ABB: SHUNT OPENING RELEASE 220...240V AC-220...250V DC XT1..XT4
Environmental Product Declaration - EPD
EPD Shunt opening releases Tmax XT XT1...XT4 (IT)
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
KXTASORE
E-Number (Finland)
3638707
E-Number (Norway)
4381319
EAN
8015644002251
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
0.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
110 mm
Package Level 1 Height
60 mm
Package Level 1 Depth / Length
140 mm
Package Level 1 Gross Weight
0.105 kg
Package Level 1 EAN
8015644002251
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT1, XT2, XT3, XT4
Suitable for Product Class
SACE Tmax XT
Configuration Type
Loose or configurable
Current Type
AC/DC
Order Multiple
1 piece
Rated Voltage (Ur)
220 ... 240 V AC | 220 ... 250 V DC
Standards
IEC60947-2 | UL489
Data Sheet, Technical Information
1SDC210100D0205 | 1SDC210099D0205
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
SOR/PS-SOR - Wired and non-wired opening release for XT1-XT2-XT3-XT4, Fixed/ Plug in CB
ETIM 8
EC002483 - Switch spool for power circuit breaker
ETIM 9
EC002483 - Switch spool for power circuit breaker
IDEA Granular Category Code (IGCC)
4879 >> Shunt release (for power circuit breaker)
Object Classification Code
Q
UNSPSC
39121601
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370421
Feature: Versatile configuration enables loose or plug-in installation. Business Impact: Accelerates retrofits and installations, reducing project lead times and field labor costs. Application: Suitable for XT1 through XT4 in retrofit projects and new builds. Feature: Dual voltage compatibility supports 220-240 VAC or 220-250 VDC. Business Impact: Minimizes spare parts and simplifies inventory planning across mixed power environments. Application: Ideal for automation cells requiring flexible control voltages. Feature: IEC60947-2 and UL489 certification alignment. Business Impact: Streamlines compliance and procurement across global sites, reducing approval cycles. Application: Used in safety-critical distribution panels and motor control applications. Feature: Lightweight, compact form with net 0.1 kg weight. Business Impact: Lowers shipping, handling, and panel mounting effort, enabling faster field deployment. Application: Fits into tight Tmax XT installations with minimal footprint. Feature: Clear documentation and part numbers for global sourcing. Business Impact: Improves BOM accuracy and reduces mis-orders, supporting just-in-time procurement. Application: US, Canada, and international projects using KXTASORE.

Get a Quick Quote for a ABB 1SDA066317R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA066317R1? Enquire Now

FAQs

Power down the panel, verify XT1–XT4 compatibility, and connect the release to the Tmax XT interface per the ABB wiring diagram. Use the KXTASORE order code where applicable and ensure a secure plug-in or loose-fit installation according to the configuration type. Follow the referenced data sheets for step-by-step guidance.
Rated voltage is 220-240 VAC or 220-250 VDC, with AC/DC current type. It is designed for XT1 through XT4 and complies with IEC60947-2 and UL489 standards, enabling safe and compatible operation in mixed-power installations.
Yes. The release supports loose or plug-in configurations and is compatible with XT1–XT4, making it suitable for both new installations and retrofits in Tmax XT switchgear. This flexibility helps minimize stock variety while maintaining safe, standardized operation.
The accessory features CE conformity, UL489 listing, and IEC60947-2 compliance. These certifications ensure regulatory alignment across regions, simplify procurement, enhance safety assurance, and support audit readiness in industrial environments.
The compact, lightweight design reduces installation time and shipping costs, while reliable tripping enhances uptime. Standardized interfaces and documentation streamline maintenance workflows and BOM accuracy, contributing to lower total cost of ownership over the life of Tmax XT installations.