ABB 1SDA066332R1 Shunt Release XT for Tmax XT - IEC60947-2

Part Number: 1SDA066332R1
Manufacturer
ABB
Part number
1SDA066332R1

Quick Summary

ABB 1SDA066332R1 Shunt Release for Tmax XT provides wired opening control for XT2–XT4 circuit-breakers. Field technicians often confront unreliable release action and unclear wiring during maintenance, risking slower responses and increased downtime. This product meets IEC60947-2 and UL489 standards, supported by REACH and RoHS declarations for material compliance, and it aligns with ABB EcoSolutions environmental commitments. Designed for 220-240 VAC / 220-250 VDC operation and compatible with XT2 and XT4 withdrawable frames, it supports AC/DC current types. As a reliable XT accessory, it simplifies installation on withdrawable frames, reduces commissioning time, and delivers predictable, safe operation, driving uptime and safer maintenance routines.

Product Information

Extended Description

1SDA066332R1 ABB: SHUNT OPENING RELEASE WIRED 220-240V AC-220-250V DC FOR WITHDRAWABLE XT2-XT4
Environmental Product Declaration - EPD
EPD Shunt opening releases Tmax XT XT1...XT4 (IT)
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
KXTCSORCWE
E-Number (Finland)
3638712
E-Number (Norway)
4381326
EAN
8015644692223
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
0.117 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
110 mm
Package Level 1 Height
60 mm
Package Level 1 Depth / Length
140 mm
Package Level 1 Gross Weight
0.123 kg
Package Level 1 EAN
8015644692223
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT2, XT4
Suitable for Product Class
SACE Tmax XT
Configuration Type
Loose or configurable
Current Type
AC/DC
Order Multiple
1 piece
Rated Voltage (Ur)
220 ... 240 V AC | 220 ... 250 V DC
Standards
IEC60947-2 | UL489
Data Sheet, Technical Information
1SDC210100D0205 | 1SDC210099D0205
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
SOR-C/PS-SOR-C Wired opening release for fixed/fixed part of withdrawable XT2-XT4 circuit-breakers
ETIM 8
EC002483 - Switch spool for power circuit breaker
ETIM 9
EC002483 - Switch spool for power circuit breaker
IDEA Granular Category Code (IGCC)
4879 >> Shunt release (for power circuit breaker)
Object Classification Code
Q
UNSPSC
39121601
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370421
Voltage and wiring compatibility: The shunt release operates across 220-240 VAC and 220-250 VDC, with AC/DC current type support, enabling use in mixed power environments and reducing mis-wiring risk. This translates to faster commissioning, fewer field errors, and dependable performance in factory automation setups utilizing XT2–XT4 withdrawable breakers. Application: control panels in manufacturing lines and energy-management systems. Standards and compliance: IEC60947-2 and UL489 certification, complemented by RoHS and REACH declarations. Business impact: simplified regulatory audits, easier supply-chain approvals, and safer cross-border installations. Application: European and North American panels requiring global certification alignment. Compatibility and installation efficiency: Configured as loose or configurable, specifically designed for XT2-XT4 frames in the Tmax XT family. Benefit: straightforward retrofits, reduced wiring complexity, and quicker field-term installation for panel builders. Application: retrofit projects and new installations in industrial controls. Environmental and documentation focus: ABB EcoSolutions support with Environmental Product Declaration (EPD) and packaging/disposal information helps sustainability reporting. Business value: aligns with corporate ESG goals and predictable waste-management practices. Application: large OEMs and panel shops prioritizing sustainable sourcing. Documentation and availability: Data sheets 1SDC210100D0205 and 1SDC210099D0205 accompany clear installation guidance, reducing commissioning errors and post-install troubleshooting. Application: procurement and commissioning teams seeking reliable reference material.

Get a Quick Quote for a ABB 1SDA066332R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA066332R1? Enquire Now

FAQs

For reliable installation, ensure compatibility with XT2-XT4 withdrawable frames and proper wiring to the shunt release terminals. Confirm AC/DC operation and that the unit is configured as loose or configurable per the frame design. Use the Data Sheets 1SDC210100D0205 and 1SDC210099D0205 as references during panel wiring and testing to prevent misconnections.
Key specs include operation at 220-240 VAC or 220-250 VDC with AC/DC current type support, and conformance to IEC60947-2 and UL489 standards. It carries RoHS and REACH declarations, with a weight of about 0.117 kg per unit and packaging details of 0.123 kg gross. EAN is 8015644692223, MOQ is 1 piece.
Yes. The 1SDA066332R1 is designed as an accessory for Tmax XT withdrawable breakers, specifically XT2 and XT4, and aligns with the Tmax XT installation footprint. Its loose/configurable configuration makes retrofits straightforward, minimizing panel downtime during upgrades or replacements.
The release carries RoHS and REACH declarations for material compliance, and ABB provides applicable TSCA declarations. This helps mitigate regulatory risk in global installations and supports compliant sourcing for multinational projects and supply chains.
The shunt release improves reliability of tripping actions, reduces field wiring errors, and shortens commissioning time, leading to lower maintenance costs and less downtime. Over time, the predictable operation of XT2-XT4 frames translates to faster service interventions and improved panel uptime, delivering measurable ROI in high-availability applications.