ABB 1SDA066693R1 Molded Case Circuit Breaker protects industrial power systems by interrupting fault currents in panel boards and switchgear. Engineers seek dependable protection that minimizes downtime, simplifies installation, and enables quick servicing. This device adheres to CE, RoHS, and REACH declarations, with TSCA and CMRT considerations that support responsible sourcing. It also aligns with IEC standards for predictable performance in global projects. The compact, front-terminal design reduces wiring complexity, while the TMF release provides reliable trip protection under overload and fault conditions. For businesses, this translates to improved uptime, lower maintenance costs, and smoother integration within ABB SACE Formula A1 protection schemes across diverse electrical environments.

Product Information

Extended Description

1SDA066693R1 ABB: C.BREAKER FORMULA A1N 125 FIXED SINGLE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 80-800 A
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Environmental Information - Formula A1-A2 | Breakers - Packaging disposal information
Order Code US and Canada
AAN080TW-1
EAN
8015644006037
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
25.4 mm
Product Net Height
130 mm
Product Net Depth / Length
60 mm
Product Net Weight
0.25 kg
Package Level 1 Units
1 piece
Package Level 1 Width
143 mm
Package Level 1 Height
74 mm
Package Level 1 Depth / Length
93 mm
Package Level 1 Gross Weight
0.3 kg
Package Level 1 EAN
8015644006037
Product Main Type
SACE FORMULA
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Electrical Durability
1500 cycle
Mechanical Durability
Nr. Operations 8500 cycle
Number of Poles
1P
Opening Time
CB with SOR 15 ms | CB with UVR 15 ms
Power Loss
at Rated Operating Conditions per Pole 9 W
Rated Current (In)
Main Circuit 80 A
Rated Impulse Withstand Voltage (Uimp)
6 kV
Rated Insulation Voltage (Ui)
690 V
Rated Operational Voltage
415 V AC | 125 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 V AC) 12.5 kA | (380 V AC) 2.5 kA | (415 V AC) 1.25 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(240 V AC) 25 kA | (380 V AC) 5 kA | (415 V AC) 5 kA | (125 V DC) 10 kA
Rated Uninterrupted Current (Iu)
125 A
Release
TMF
Release Type
TM
Short-Circuit Performance Level
N
Standards
IEC
Sub-type
A1
Terminal Connection Type
Front
Data Sheet, Technical Information
1SDC210032D0204
Declaration of Conformity - CE
EC Declaration of Conformity Formula DSA A1
Wiring Diagram
Wiring diagram FORMULA A1-A2
Instructions and Manuals
Installation Instructions Formula A1/I-II
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front-terminal 1P design with TMF release simplifies wiring and enables fast maintenance. Business Impact: Reduces on-site wiring errors and downtime, delivering faster panel upgrades and easier field servicing. Application: Ideal for main circuit protection in control panels and switchgear using ABB SACE Formula A1 components. Long-tail keywords: front-terminal connection, TMF release, 1P circuit breaker, molded case breaker, ABB SACE. Feature: 80 A rated current with 6 kV impulse withstand and 690 V insulation voltage supports robust protection for standard industrial loads. Business Impact: Safe, reliable interruption of fault currents at typical plant feeder levels, lowering risk of equipment damage. Application: Main feeders in production lines and substations. Long-tail keywords: rated current 80 A, Uimp 6 kV, Ui 690 V, IEC protection. Feature: Short-circuit capability with Ics up to 12.5 kA (240 V) and Icu up to 25 kA (240 V) ensures fast fault clearing. Business Impact: Minimizes arc flash potential and equipment exposure during faults, preserving uptime. Application: Transformer protection and main switchgear protection. Long-tail keywords: Ics 12.5 kA, Icu 25 kA, short-circuit capacity. Feature: Compact footprint and lightweight design (25.4 mm width, 130 mm height, 60 mm depth; 0.25 kg). Business Impact: Easier cabinet integration, lower enclosure space requirements, and reduced install time. Application: New installs and upgrades in limited-space panels. Long-tail keywords: compact MCB, 25.4 mm width, 60 mm depth. Feature: Front termination type with standard mechanical durability (1500 cycle electrical, 8500 cycle mechanical). Business Impact: Durable service life with predictable maintenance intervals and reduced replacement costs. Application: Frequent operation environments and high-cycle applications. Long-tail keywords: front connection, electrical durability, mechanical durability. Feature: Compliance and packaging information including CE, RoHS, REACH, TSCA, and CMRT declarations. Business Impact: Simplified procurement with traceable supply chain compliance. Application: Global projects requiring regulatory alignment. Long-tail keywords: RoHS compliant, REACH declaration, CMRT.

Get a Quick Quote for a ABB 1SDA066693R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA066693R1? Enquire Now

FAQs

Installers should ensure compatible enclosure dimensions and busbar spacing for a front-terminal MC B. Tighten terminals to manufacturer torque values, verify proper insulation distances, and plan for accessible wiring space to facilitate TMF maintenance and periodic testing.
TMF release provides thermal and magnetic trip functionality, delivering fast response to overload and short-circuit conditions. This improves fault clearance times, reduces arc exposure, and enhances system reliability in critical main-circuit protections.
Yes. The device has a rated operating voltage of 415 V AC and 125 V DC, with insulation rated up to 690 V, making it compatible with typical industrial power distribution in both AC and DC auxiliary circuits.
The product ships with CE Declaration of Conformity, RoHS information, REACH declaration, TSCA declaration, and CMRT. These documents support regulatory compliance, responsible sourcing, and supply-chain transparency for global projects.
Benefits include reduced downtime due to simpler wiring and faster servicing, lower energy loss (about 9 W per pole), and high mechanical durability (8500 cycles). These factors translate to longer service intervals and lower lifecycle costs in industrial installations.