ABB 1SDA066726R1 Moulded Case Circuit Breaker - TMF

Part Number: 1SDA066726R1
Manufacturer
ABB
Part number
1SDA066726R1

Quick Summary

ABB 1SDA066726R1 Moulded Case Circuit Breaker protects critical power circuits in industrial panels, delivering reliable overcurrent protection for mains up to 50 A. This device addresses common panel-assembly challenges such as space constraints, wiring complexity, and the need for predictable tripping under fault conditions. As part of ABB’s SACE Formula family, it aligns with CE conformity, RoHS/REACH compliance, and TSCA considerations, ensuring global acceptance. The TMF release and front-terminal design offer installation efficiency and consistent performance in demanding environments. With robust certification and a compact footprint, it supports safer, faster maintenance and lower lifecycle costs for industrial customers and electrical contractors alike.

Product Information

Extended Description

1SDA066726R1 ABB: C.BREAKER FORMULA A1N 125 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 50-500 A
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Environmental Information - Formula A1-A2 | Breakers - Packaging disposal information
Order Code US and Canada
AAN050TW
EAN
8015644006365
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
60 mm
Product Net Weight
0.793 kg
Package Level 1 Units
1 piece
Package Level 1 Width
136.5 mm
Package Level 1 Height
124 mm
Package Level 1 Depth / Length
110.5 mm
Package Level 1 Gross Weight
0.8 kg
Package Level 1 EAN
8015644006365
Product Main Type
SACE FORMULA
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Electrical Durability
1500 cycle
Mechanical Durability
Nr. Operations 8500 cycle
Number of Poles
3P
Opening Time
CB with SOR 15 ms | CB with UVR 15 ms
Power Loss
at Rated Operating Conditions per Pole 5.5 W
Rated Current (In)
Main Circuit 50 A
Rated Impulse Withstand Voltage (Uimp)
6 kV
Rated Insulation Voltage (Ui)
690 V
Rated Operational Voltage
550 V AC | 250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 V AC) 50 kA | (380 V AC) 18 kA | (415 V AC) 7.5 kA | (440 V AC) 6.25 kA | (480 V AC) 4.5 kA | (500 V AC) 2.5 kA | (250 V DC) 2 Poles in Series 5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(240 V AC) 100 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 25 kA | (480 V AC) 18 kA | (500 V AC) 10 kA | (250 V DC) 10 kA
Rated Uninterrupted Current (Iu)
125 A
Release
TMF
Release Type
TM
Short-Circuit Performance Level
N
Standards
IEC
Sub-type
A1
Terminal Connection Type
Front
Data Sheet, Technical Information
1SDC210032D0204
Declaration of Conformity - CE
EC Declaration of Conformity Formula DSA A1
Wiring Diagram
Wiring diagram FORMULA A1-A2
Instructions and Manuals
Installation Instructions Formula A1/III-IV
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: 1) Three-pole TMF release with front terminals enables quick wiring and reliable venting, reducing installation time in crowded control panels and minimizing miswiring risk in high-density switchgear environments. This translates to lower labor costs and faster panel commissioning for new builds and retrofits in manufacturing lines. 2) Rated current of 50 A and adequate Iu of 125 A provide strong protection for main feeders while maintaining acceptable voltage drop in general industrial power distribution, improving system availability in continuous operation environments such as packaging or automotive assembly lines. 3) Short-circuit performance up to 50 kA (Ics at 240 V AC) and 36 kA (Icu at 380–415 V AC) deliver dependable fault interruption for transformer-fed systems, enabling safer shutdowns and reducing arc-flash exposure during faults in medium-voltage distribution. 4) High insulation voltage Ui of 690 V and rated impulse withstand 6 kV support safe operation in mixed AC/DC feeder configurations common in modern plants, enhancing protection in mixed-signal and power environments. 5) Electrical durability of 1500 cycles and mechanical durability of 8500 cycles offer predictable lifecycle performance in high-usage panels, delivering lower maintenance costs and fewer replacements over time. 6) Compact dimensions with a net width of 76.2 mm, height 130 mm, and depth 60 mm support denser panel layouts and easier retrofits, improving overall cabinet economics for OEMs and integrators. 7) Product data and compliance documentation, including RoHS/REACH declarations and CE declarations, streamline regulatory audits and supplier qualification for global projects. 8) Compatibility with standard wiring diagrams and installation instructions (Wiring Diagram FORMULA A1-A2; Installation Instructions Formula A1/III-IV) reduces ambiguity during installation and accelerates commissioning in diverse industrial environments.

Get a Quick Quote for a ABB 1SDA066726R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA066726R1? Enquire Now

FAQs

This unit uses front-terminal connections, which simplifies wiring in tight panel spaces and reduces risk of cross‑contact during assembly. Its 3P configuration and compact footprint (76.2 mm wide, 130 mm high, 60 mm deep) fit standard DIN rail or screwed mounting in industrial panels. Ensure proper labeling and adherence to the Wiring Diagram FORMULA A1-A2 to maintain clear traceability for maintenance and regulatory audits.
The breaker is rated for 50 A main current with a rated insulation voltage of 690 V and a rated operational voltage up to 550 V AC / 250 V DC. It offers a 6 kV impulse withstand and short-circuit breaking capacities of up to 50 kA (Ics at 240 V AC) and 18–7.5 kA across higher voltages (380–500 V AC). Release is TMF with a 3P front connection, delivering reliable protection in transformer or generator feeder circuits and enabling safe disconnection under fault conditions.
Yes. The product carries a REACH declaration, RoHS information and RoHS status aligned with EU Directive 2011/65/EU and Amendment 2015/863, and a CE Declaration of Conformity for Formula A1. These certifications simplify regulatory approvals, supplier qualification, and global market access for industrial equipment installed in factories, utilities, and infrastructure projects.
Electrical durability is rated at 1500 operating cycles and mechanical durability at 8500 operations, with a rated uninterrupted current of 125 A. This combination supports long service life in high-demand environments, reduces unscheduled maintenance, and lowers replacement costs for critical feeders and distribution panels in continuous‑operation facilities such as automotive lines or process industries.
Ideal for power distribution in industrial panels, transformers, and generator protection where reliable 3P protection is essential. As part of ABB SACE Formula, it offers a front-terminal design, TMF release, and strong Ics/Icu ratings that balance protection with compact form factor. Compared with alternatives, this MCCB delivers robust compliance (IEC, CE, RoHS) and a predictable lifecycle, making it a strong choice for OEMs seeking efficient installation and lower maintenance costs in high‑volume manufacturing or utility installations.