ABB 1SDA066730R1 Moulded Case Circuit Breaker - TMF IEC

Part Number: 1SDA066730R1
Manufacturer
ABB
Part number
1SDA066730R1

Quick Summary

ABB 1SDA066730R1 Moulded Case Circuit Breaker protects industrial power circuits in panel installations. Engineers often face downtime and nuisance trips; this unit delivers reliable protection with front-terminal installation and fast operation. CE conformity, IEC standards, and RoHS/TSCA declarations ensure global compliance, while the SACE Formula TMF release and 3P configuration provide scalable protection. By combining robust protection with straightforward wiring and installation, it delivers measurable business value through reduced maintenance, predictable trip behavior, and enhanced panel reliability. This makes it a practical choice for industrial automation projects, machine builders, and power distribution upgrades where safety and uptime matter most.

Product Information

Extended Description

1SDA066730R1 ABB: C.BREAKER FORMULA A1N 125 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 90-900 A
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Environmental Information - Formula A1-A2 | Breakers - Packaging disposal information
Order Code US and Canada
AAN090TW
EAN
8015644006402
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
60 mm
Product Net Weight
0.75 kg
Package Level 1 Units
1 piece
Package Level 1 Width
136.5 mm
Package Level 1 Height
124 mm
Package Level 1 Depth / Length
110.5 mm
Package Level 1 Gross Weight
0.8 kg
Package Level 1 EAN
8015644006402
Product Main Type
SACE FORMULA
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Electrical Durability
1500 cycle
Mechanical Durability
Nr. Operations 8500 cycle
Number of Poles
3P
Opening Time
CB with SOR 15 ms | CB with UVR 15 ms
Power Loss
at Rated Operating Conditions per Pole 7 W
Rated Current (In)
Main Circuit 90 A
Rated Impulse Withstand Voltage (Uimp)
6 kV
Rated Insulation Voltage (Ui)
690 V
Rated Operational Voltage
550 V AC | 250 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(240 V AC) 50 kA | (380 V AC) 18 kA | (415 V AC) 7.5 kA | (440 V AC) 6.25 kA | (480 V AC) 4.5 kA | (500 V AC) 2.5 kA | (250 V DC) 2 Poles in Series 5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(240 V AC) 100 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 25 kA | (480 V AC) 18 kA | (500 V AC) 10 kA | (250 V DC) 10 kA
Rated Uninterrupted Current (Iu)
125 A
Release
TMF
Release Type
TM
Short-Circuit Performance Level
N
Standards
IEC
Sub-type
A1
Terminal Connection Type
Front
Data Sheet, Technical Information
1SDC210032D0204
Declaration of Conformity - CE
EC Declaration of Conformity Formula DSA A1
Wiring Diagram
Wiring diagram FORMULA A1-A2
Instructions and Manuals
Installation Instructions Formula A1/III-IV
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
The 3P front-terminal design enables seamless integration into standard switchboards and control panels, reducing wiring time and minimizing space requirements while improving reliability in crowdedctrl environments. The 90 A rated current supports mid-range feeders and motor loads, delivering consistent protection without unnecessary nuisance trips and enabling better coordination with upstream protections. With TMF release and TM trip type, the device provides fast, predictable opening times (15 ms) under fault conditions, helping to minimize arc energy and downstream damage. Power loss of 7 W per pole translates to cooler operation and lower cooling costs, which is vital for dense panel arrays. RoHS and REACH declarations ensure material compliance, while TSCA confirms regulatory acceptance in North American markets. The unit’s front-terminal connection simplifies retrofits and new installations alike, supporting quick commissioning and easier maintenance. Compatibility with SACE Formula products enhances system-wide protection strategies in transformer stations and industrial drives. The combination of 1500 electrical and 8500 mechanical cycles underlines long-term durability, reducing replacement frequency and improving total cost of ownership. Additional information such as 1-piece minimum order, packaging details, and the 8015644006402 EAN supports straightforward procurement and logistics, enabling faster project delivery and reduced downtime during spares planning.

Get a Quick Quote for a ABB 1SDA066730R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA066730R1? Enquire Now

FAQs

This device uses front-terminal connections, enabling straightforward wiring in standard panel cutouts and easy retrofits. The 3P configuration supports organized busbar layouts, reducing wiring complexity and improving accessibility for maintenance and testing.
Rated current is 90 A with a rated insulation voltage of 690 V and a rated impulse withstand voltage of 6 kV. Service short-circuit capacity (Ics) ranges up to 50 kA at 240 V AC, and ultimate short-circuit capacity (Icu) reaches up to 100 kA at 240 V AC. Operational voltage is 550 V AC / 250 V DC, supporting diverse industrial applications.
Yes. It is designed for SACE Formula protection schemes and ETIM EC000228 classification, making it suitable for transformer and generator protection within switchgear and protection panels. Its front-terminal design and TMF release support reliable coordination in transformer substations and industrial drives.
The product carries CE conformity, IEC standards alignment, RoHS compliance (EU Directive 2011/65/EU and 2015/863), and TSCA declarations. CMRT data is available for conflict minerals, supporting due diligence in supply chains.
With electrical durability rated at 1500 cycles and mechanical durability at 8500 cycles, the device provides long service life and predictable performance. Low heat dissipation (7 W per pole) reduces cooling needs, and front-terminal wiring simplifies installation and maintenance, contributing to lower lifecycle costs and faster project ROI.