Moulded Case Circuit Breaker from ABB provides reliable overcurrent protection for low‑voltage distribution panels. Engineers often contend with nuisance trips, downtime, and mounting complexities when upgrading protection in expanding industrial facilities. This XT1 family device aligns with IEC 60947-2 and CE conformity, backed by GL and LR approvals that support regulatory compliance and traceability. By combining a compact 3P XT1 architecture with front terminals and a precise TMD release, it delivers installation efficiency, safer operation, and a lower total cost of ownership for panel builders and maintenance teams.
Product Information
Extended Description
1SDA066801R1 ABB: C.BREAKER TMAX XT1B 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 25-450 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
8acd1baa-b059-4d51-abdc-ea46defeb35e Italy (IT)
Simplified SCIP
d1aaf08d-e25f-4668-a057-4628057c8769 Germany (DE) | a3cb6bff-8410-4229-8646-6cccfa9434c2 Poland (PL) | 9ff0f6b4-a69c-43a0-ba19-92bc124a3464 Norway (NO) | 2b859db5-b8d7-4582-9f9e-a714dfb57603 Finland (FI) | 2c089ba4-fd3a-4e3d-b3da-8607a803d823 Netherlands (NL) | d265c6de-5560-448d-be55-8b6e38c8e47e Germany (DE) | e0d795ac-e812-48bb-93ae-39c2b1fe2aa8 Denmark (DK) | b9b12f17-54ef-40cc-8b89-a4e1a85e6f16 Germany (DE) | c6298b97-9d9e-42ed-b595-bc5572008f7f Croatia (HR) | 49905c59-d051-4933-aee8-957313e7c76b France (FR) | 49a55cdf-4a0f-48db-a710-1f0b682d75da Sweden (SE) | ba601371-442d-4856-91e4-aed91c4397a6 Germany (DE) | 96e8b14b-e8c2-4ff3-b457-9d321b80a48c Germany (DE) | f834e079-b952-4094-819d-77fa6c5c2e9f France (FR) | ef2515cc-3f80-4037-9726-465563cd6237 Netherlands (NL) | 755304cd-f665-4b13-9cf6-10f93e474874 Spain (ES) | efe35e1a-4e77-4211-bebc-18b4ca05a992 Estonia (EE) | c6675afb-be78-4a8f-9a37-e2fbbce32849 Greece (GR) | f105555f-afc7-4bfc-8428-6db856df2c98 Portugal (PT) | 243cc790-2e64-4328-97df-dd54d53fbcd3 Bulgaria (BG) | f8571fb3-a76a-45f5-b32b-a8fb8bc01539 Sweden (SE) | 0f189183-bc01-4cac-acea-7637fb6a169a Poland (PL) | dbf95c07-c982-4c67-8a65-b5087833b881 Netherlands (NL) | f099941a-3638-4e46-bc58-30dd8b7335ab Czech Republic (CZ) | 29ca709b-7996-405d-bd6d-5d766c178307 Poland (PL) | 8a2dc3a6-691e-442a-b562-b5f3081e360d Netherlands (NL) | ed75ce49-731b-4a2c-a2aa-48b67198a8ec Netherlands (NL)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1BE3025AFF000XXX
E-Number (Finland)
3640497
E-Number (Norway)
4309602
EAN
8015644003289
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.126 kg
Package Level 1 EAN
8015644003289
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2 W
Rated Current (In)
25 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
450 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 25 kA | (230 V AC) 25 kA | (240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 18 kA | (440 V AC) 11.25 kA | (500 V AC) 8 kA | (525 V AC) 6 kA | (690 V AC) 3 kA | (250 V DC) 2 Poles in Series 18 kA | (500 V DC) 3 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 25 kA | (230 V AC) 25 kA | (240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 18 kA | (440 V AC) 15 kA | (500 V AC) 8 kA | (525 V AC) 6 kA | (690 V AC) 3 kA | (250 V DC) 2 Poles in Series 18 kA | (500 V DC) 3 Poles in Series 18 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
17.5...25 A
Short-Circuit Performance Level
B
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front-terminal, bolt connection design enables quick, secure wiring and simplified cabinet layout. Benefit: Reduces installation time and error risk, improving overall project lead times in control panels and switchgear assemblies. Application: Suitable for 3P low‑voltage distribution where reliable front‑mount termination is required. Feature: 690 V rated operational voltage and 800 V Ui with 25 A In. Benefit: Supports modern MV/LV interface protection with ample headroom for surge and switching transients, minimizing nuisance outages in transformer and MCC applications. Application: Transformer protection in power distribution and motor control centers. Feature: Setting range 17.5–25 A and IPD release (TMD). Benefit: Adjusts protection to match precise load profiles, reducing nuisance tripping while ensuring safe shutdown during faults. Application: Fine‑tuned protection in automation panels and busbar systems. Feature: Icu and Ics ratings (up to 25 kA, depending on voltage). Benefit: Strong short‑circuit protection across a wide voltage spectrum, supporting compliance with stringent fault‑clearing requirements. Application: Industrial automation rooms, generator interfaces, and feeder protection. Feature: 3P XT1 design with busbar connection (45.5–80 mm²). Benefit: Optimized for compact footprints and reliable conductor termination, lowering panel space requirements. Application: New panel builds and retrofits in compact switchgear. Feature: RoHS/REACH compliance and extensive environmental data (EPD, recyclability). Benefit: Helps meet sustainability targets while simplifying end‑of‑life planning and regulatory reporting. Application: Green facilities programs and compliance reporting for electrical installations.
Get a Quick Quote for a ABB 1SDA066801R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA066801R1?
Enquire Now
FAQs
The XT1 3P unit uses front terminal bolts for secure wiring and is compatible with busbars sized 45.5 to 80 mm². Its front‑mounted design simplifies panel layout and permits straightforward retrofits in existing SACE Tmax XT systems, reducing commissioning time while maintaining compliance with IEC60947-2 standards.
Setting range is 17.5 to 25 A, with a rated instantaneous short‑circuit current setting Ii of 450 A. The device supports up to 25 kA rated service and up to 25 kA rated ultimate short‑circuit breaking capacity at applicable voltages, ensuring strong protection for feeders and transformers under fault conditions.
Yes. With 690 V rated operating voltage, 25 A nominal current, and robust Icu/Ics ratings, the XT1 is well suited for transformer protection in LV networks and MCCs. Its front‑terminal, 3P XT1 configuration aligns with common transformer interfaces while meeting IEC 60947‑2 requirements.
The device carries CE conformity (EC DoC Tmax XT1), GL and LR certifications, and manufacturer statements for RoHS/REACH compliance. Other certifications noted include UL and VDE where applicable, with environmental data and disassembly guidance supporting sustainability and regulatory reporting.
Front termination reduces wiring labor and misconnection risk during installation. The combination of robust mechanical/electrical durability, clear wiring diagrams, and standardized dimensions simplifies maintenance, stocking, and replacements, contributing to lower lifecycle costs and faster downtime recovery in automation facilities.