ABB 1SDA066803R1 Moulded Case Circuit Breaker - IEC 60947-2
Part Number: 1SDA066803R1
Quick Summary
ABB 1SDA066803R1 Moulded Case Circuit Breaker provides reliable overcurrent protection for 690 V distribution. Engineers need front-terminal solutions that simplify installation and minimize mis-wiring in compact switchgear. CE conformity is confirmed with IEC 60947-2 as the governing standard for this device. ABB EcoSolutions support sustainable design through end-of-life disassembly, EPDs, and recyclability data. In practice, this combination translates to reliable protection, faster installation, and a lower total cost of ownership in industrial power distribution.
Product Information
Extended Description
1SDA066803R1 ABB: C.BREAKER TMAX XT1B 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 40-450 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
5cab19a8-a211-40c5-bc9a-598007736c08 Italy (IT)
Simplified SCIP
abcf1fa6-993f-40bd-948e-7031a129c6fd Spain (ES) | 2909f5f6-ef26-4852-a421-00343f2a1bf8 Belgium (BE) | 235f26cb-78ea-4142-86a8-40c6d9269936 Czech Republic (CZ) | b696f5da-3bb1-4927-8e16-fbeb5af0d012 Hungary (HU) | d0e32a4a-d6ae-4037-9851-caecdc49d0d1 France (FR) | bb77a6d6-2708-474c-9f92-8318a5904431 Germany (DE) | 617944fc-cc3f-4139-be4e-7081dda306fe Sweden (SE) | 55adadea-3c4a-42ca-8e5b-951e0b147e82 Germany (DE) | a7a3ee97-4148-4339-8171-d93ccb74797e Denmark (DK) | f9f02b49-3f65-40ed-8d49-47307e1ed2cc Germany (DE) | 67490311-ba58-4d42-b7a3-a1906ce91f7d Germany (DE) | f99a2448-1391-42bf-a0b1-c2bc741303dd Croatia (HR) | edb092a4-db53-4f4d-ac32-e7197c9fc30f Sweden (SE) | 29bd069c-9cf7-451d-a67b-e19c26a6024f Netherlands (NL) | 52315325-7b94-42a9-a354-6b77d2f4ecb3 Poland (PL) | 8a890085-a4df-4f26-8327-093b43f9d1c2 Bulgaria (BG) | f66a5efb-a803-42ba-866b-e1fecc118301 Norway (NO) | 6133c899-40e7-4adc-8cd3-cfd3163257c9 Germany (DE) | c6867efd-1d68-44fd-830a-c3cbfac0122a Portugal (PT) | 8650c8bf-2467-49e7-9e5a-2a12ae456925 Poland (PL) | bad829f3-7ca9-408f-b042-c31ab585e58e Greece (GR) | c3fa5ce2-5f63-4b2e-a6c1-0b728aa19a97 France (FR) | afa820e1-182b-4046-a65a-c721fbd0877f Estonia (EE) | f2d51ade-ddb7-40d4-bc3f-bf975ca32912 Belgium (BE) | 00ad4c8c-baf2-406d-aec8-f7ce17297da9 Hungary (HU) | ecb413a7-766a-4b40-8eef-164b819c6b12 Poland (PL) | 241539ed-acf4-4841-92dd-cb32075995b6 Finland (FI)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1BE3040AFF000XXX
E-Number (Finland)
3638025
E-Number (Norway)
4309604
EAN
8015644003302
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.124 kg
Package Level 1 EAN
8015644003302
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2.6 W
Rated Current (In)
40 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
450 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 25 kA | (230 V AC) 25 kA | (240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 18 kA | (440 V AC) 11.25 kA | (500 V AC) 8 kA | (525 V AC) 6 kA | (690 V AC) 3 kA | (250 V DC) 2 Poles in Series 18 kA | (500 V DC) 3 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 25 kA | (230 V AC) 25 kA | (240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 18 kA | (440 V AC) 15 kA | (500 V AC) 8 kA | (525 V AC) 6 kA | (690 V AC) 3 kA | (250 V DC) 2 Poles in Series 18 kA | (500 V DC) 3 Poles in Series 18 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
28...40 A
Short-Circuit Performance Level
B
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Front-terminal, 3P XT1 design with 40 A rating and 690 V operation enables fast, secure wiring in space-constrained panels, reducing commissioning time and wiring errors for engineers. This directly improves installation efficiency in motor control Centers and distribution boards. Feature → Business Impact → Application: 45.5 to 80 mm2 busbar compatibility and 6 N·m tightening torque ensure robust, repeatable connections, lowering the risk of loose-terminals during high-power startup in manufacturing lines. Feature → Business Impact → Application: Thermomagnetic release (TMD) with a 28–40 A setting range and 450 A instantaneous trip offers precise coordination with downstream protection schemes, minimizing nuisance trips and safeguarding critical loads in process plants. Feature → Business Impact → Application: Rated impulse withstand voltage of 8 kV and Icu up to 25 kA at common voltages deliver dependable short-circuit protection for transformers and feeders, reducing unplanned downtime in data centers and utility interfaces. Feature → Business Impact → Application: Environmental and end-of-life data, including EPDs and 55.9% recyclability per EN45555, support compliant, sustainable asset management in regulated industries and long lifecycle programs.
Get a Quick Quote for a ABB 1SDA066803R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA066803R1?
Enquire Now
FAQs
This unit features front-terminal connections and is designed for 3-phase duty. Use busbars in the 45.5 to 80 mm² range and tighten terminals to 6 N·m to ensure a secure, vibration-resistant connection. Plan for 3P installation with 690 V systems and verify panel clearances for the 130 mm height and 76.2 mm width.
Rated current is 40 A, rated voltage 690 V, and rated impulse withstand voltage 8 kV. It provides a setting range of 28–40 A and a rated ultimate short-circuit breaking capacity up to 25 kA across common voltages, with 3P operation and front-terminal design for reliable protection.
Yes. The device adheres to IEC 60947-2 standards and includes a CE Declaration of Conformity. With 3P configuration, front terminals, and robust short-circuit protection, it is well-suited for data-center feeder protection and transformer protection in compliant power architectures.
CE conformity is documented via the EC Declaration of Conformity for Tmax XT1. UL and VDE certifications are not required for this variant, while RoHS, REACH, and EPD data are provided, alongside recyclability information (55.9% per EN45555) to support sustainable procurement.
The front-terminal design simplifies installation, reducing commissioning time and wiring errors. Its robust protection (8 kV, 25 kA) minimizes downtime after faults, while end-of-life data and recyclability support lower lifecycle costs and easier regulatory compliance, delivering a favorable total cost of ownership in industrial facilities.