ABB 1SDA066804R1 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 1SDA066804R1
Quick Summary
ABB 1SDA066804R1 Moulded Case Circuit Breaker provides robust overcurrent protection for industrial power distribution. Engineers often wrestle with cramped panels, complex wiring, and downtime, and this XT1 device addresses those challenges with front terminals and a compact 3P design. It carries CE conformity (EC Declaration of Conformity Tmax XT1) along with GL and LR certifications, underscoring European quality control and traceability for critical infrastructure. Built for reliability and ease of integration, it supports IEC60947-2 compliance while delivering predictable protection, enabling safer installations, reduced maintenance costs, and better energy efficiency. This makes it a strong fit for ABB's SACE Tmax XT family in industrial plants, providing a scalable solution for transformer and distribution protection.
Product Information
Extended Description
1SDA066804R1 ABB: C.BREAKER TMAX XT1B 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 50-500 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
a10a99fa-25ac-433d-b62d-7689b50c5c6c Italy (IT)
Simplified SCIP
41cd25de-2393-4a57-97ea-cc906e39537c Germany (DE) | 69cd6212-a899-4286-a772-8f474dc6c2bb Poland (PL) | 37f17624-f471-4fd3-9b01-4c3625894ed3 Norway (NO) | 4a34c8c8-9faf-4d2f-a59b-f51d5cdd4e8d Finland (FI) | 5537a32c-26dc-4c9d-bc95-cb9905d66cfc Netherlands (NL) | ef53c3b5-bc52-49fb-b855-7a8f21515267 Germany (DE) | 56d03ad1-bd96-4376-9736-79e2ef64f4ab Denmark (DK) | b3206c37-260c-4ebf-b240-4996b994f65d Germany (DE) | ddb77a11-e6f5-4b70-bf76-a947793ddf48 Croatia (HR) | 2c66013a-028e-4ca1-ac7d-2a830f47a45b Czech Republic (CZ) | 6dcf4af9-a40a-4f40-9d60-663b40bbfdc5 Poland (PL) | 614bc1e9-9182-4efb-aa78-e6e9372fd979 Netherlands (NL) | e9e72111-5dc6-449c-afad-bfb9bf049e48 Netherlands (NL) | b9ea0014-b614-4eed-a49a-4a83d350ab8b Estonia (EE) | f45570f0-233c-43c3-9f60-758b79f8fb85 Greece (GR) | 2d3090e5-4296-4969-815a-fc359c86aeef Portugal (PT) | ef329402-0bc6-458f-adc4-ca0f59af1e1c Bulgaria (BG) | 025d7c1b-8c66-4efe-8e49-75d8efc43eba Sweden (SE) | 5be09893-83ce-4487-b2ec-d9a313525d19 Poland (PL) | fcfc9e57-aec8-4b59-a24d-f90af6d29625 France (FR) | 338fd03f-9159-443a-9b5a-4a9e4e3be02e Sweden (SE) | a0316fa6-51b1-46f4-ae1e-139caf62298e Germany (DE) | 149a8272-3a2b-4d5c-8608-5789a28b417d Germany (DE) | c4ea13ca-23b7-43e3-afbb-04d28a093f11 France (FR) | 3e5bb53d-feda-4a12-a764-6f9cf645e4c7 Netherlands (NL) | 513eef80-bdee-472a-815e-31c738e5c4da Spain (ES) | bff7649f-dcc0-4167-b394-414dac45600a Netherlands (NL)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1BE3050AFF000XXX
E-Number (Finland)
3640498
E-Number (Norway)
4309605
EAN
8015644007119
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.134 kg
Package Level 1 EAN
8015644007119
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 15 ms | CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 3.7 W
Rated Current (In)
50 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 25 kA | (230 V AC) 25 kA | (240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 18 kA | (440 V AC) 11.25 kA | (500 V AC) 8 kA | (525 V AC) 6 kA | (690 V AC) 3 kA | (250 V DC) 2 Poles in Series 18 kA | (500 V DC) 3 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 25 kA | (230 V AC) 25 kA | (240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 18 kA | (440 V AC) 15 kA | (500 V AC) 8 kA | (525 V AC) 6 kA | (690 V AC) 3 kA | (250 V DC) 2 Poles in Series 18 kA | (500 V DC) 3 Poles in Series 18 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
35...50 A
Short-Circuit Performance Level
B
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: 50 A rated current with 690 V and Icu 25 kA ensures reliable protection against short-circuits, preventing fault propagation in feeders and transformers. Business Impact: minimizes downtime, reduces risk of equipment damage, and supports compliant panel design. Application: ideal for main circuits in industrial power distribution and protection schemes. Feature: Front terminal connection with Bolt terminals and 6 N·m tightening torque enables fast, secure wiring and repeatable assembly. Business Impact: shortens installation time, lowers commissioning costs, and improves wiring quality. Application: suitable for modular switchgear and control panels with space constraints. Feature: Release TMD with TM type and a setting range of 35–50 A provides tailored protection for varying load profiles. Business Impact: precise discrimination of protective action, fewer nuisance trips, and better system uptime. Application: motor and transformer protection within the Tmax XT family. Feature: 3P XT1 sub-type with IEC60947-2 compliance offers standardized performance and interoperability. Business Impact: easier replacement, certified performance, and simplified maintenance planning. Application: cross-panel deployment across multiple lines. Feature: Mechanical Durability 25000 cycles and Electrical Durability 8000 cycles translate to long service life. Business Impact: lower lifecycle costs, less frequent replacements, and improved total cost of ownership. Application: high-demand industrial environments with frequent switching. Feature: Environmental and recyclability data including EPD, EN45555 Closing Resource Loops, and RoHS/REACH declarations support responsible procurement. Business Impact: supports sustainability reporting, regulatory compliance, and waste reduction. Application: design for end-of-life disassembly and recycling in plant refurbishments.
Get a Quick Quote for a ABB 1SDA066804R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA066804R1?
Enquire Now
FAQs
This device uses front bolt terminals, requiring a tightening torque of 6 N·m. It supports busbar connections from 45.5 to 80 mm² and requires a main circuit screwdriver (M6) for secure assembly, making wiring quicker and more reliable in panel builds.
It is a 3PXT1 device with a rated current of 50 A, rated voltage of 690 V, Uimp of 8 kV, and a universal current setting range of 35–50 A. Its short-circuit capabilities include Ics/Icu up to 25 kA, suitable for demanding industrial protection schemes.
Yes. The 1SDA066804R1 is part of the SACE Tmax XT family and is designed for transformer and motor protection in low-voltage networks, offering reliable tripping with fast opening times and compatible accessories for installation in switchgear and distribution panels.
The device carries CE conformity (EC Declaration of Conformity Tmax XT1) and is supported by GL and LR certificates. It also provides an Environmental Product Declaration (EPD) and meets RoHS/REACH requirements, with recyclability information aligned to EN45555.
Product net width is 76.2 mm, height 130 mm, depth 70 mm, and net weight 1.1 kg. Package level data lists 1 piece per box, with gross dimensions and EAN 8015644007119 for stock management and shipping calculations.