ABB 1SDA066805R1 Moulded Case Circuit Breaker - 690V
Part Number: 1SDA066805R1
Quick Summary
ABB 1SDA066805R1 Moulded Case Circuit Breaker provides reliable protection for low- to medium-voltage electrical circuits in industrial power distribution. Engineers often struggle to balance robust short-circuit protection with quick installation and ongoing maintenance costs. This device conforms to IEC 60947-2, carries a CE Declaration of Conformity, and supports RoHS compliance, helping you meet global regulatory requirements with minimal risk. In Tmax XT ecosystems it integrates with EcoSolutions for longevity and safer operation, supporting predictable maintenance planning. Designed for panel builders and plant managers, it offers a compact footprint and straightforward wiring, delivering safer, more economical protection across diverse industrial applications.
Product Information
Extended Description
1SDA066805R1 ABB: C.BREAKER TMAX XT1B 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 63-630 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
377a9c61-7755-44c1-97ff-a07aff56de9b Italy (IT)
Simplified SCIP
86faf432-330b-45a6-841a-9df0d6acd302 Germany (DE) | daa01f6d-1f3e-4502-af6c-0af85208954c France (FR) | cdf3a55e-573c-4e5f-9073-888525925d22 Sweden (SE) | d50e69f4-3b07-4b77-8c24-aa3b9f65ba99 Germany (DE) | 461979f8-a2e7-4c07-b7a8-1728bc14a555 Germany (DE) | 957cd3ec-bfde-4be3-b8df-3b6f3838373f France (FR) | 163d5b2f-de04-4a5b-ae2b-a1ebbc7fe914 Netherlands (NL) | 81b3c985-b241-435c-8df6-0a584b927c14 Spain (ES) | 427d8ee9-7e25-405c-a7f4-e848305aad8b Netherlands (NL) | 01b87aaa-b947-4047-a80d-782b44892605 Estonia (EE) | cf3f2f86-1bad-444c-8269-0e9f91157c9c Greece (GR) | 086834cb-61eb-4fa3-93fd-52c04adbaf77 Portugal (PT) | 20059d7b-e633-4722-a642-9f0af013a7f9 Bulgaria (BG) | 3d72fe1b-17d0-4aaf-b98c-b1052d324abb Sweden (SE) | 4c6c4237-6ab3-486d-85da-810ae805ab09 Poland (PL) | d1a2266e-fb4f-4b1b-a238-aa97da55dca0 Germany (DE) | a933ee30-b187-4bbb-8496-a75ed35945ef Denmark (DK) | f8ef55b6-40f1-4987-b02e-0cc1abc70db1 Germany (DE) | 1dfdbbb1-512d-4648-b1ec-2824cf82b27f Croatia (HR) | 47d2c496-8e17-438c-86d2-3e5d4828c553 Czech Republic (CZ) | 91f97945-0df9-4bcf-8bed-a81030f98474 Poland (PL) | ced992aa-980d-40fa-b367-b8a962eeb016 Netherlands (NL) | 4d7da6aa-719c-43fd-a6f6-2f6fe4924477 Poland (PL) | 14709c0d-402b-47ae-8722-84da0e53b6f6 Norway (NO) | 7368f8f4-2303-4d60-9b04-464610d2de5f Finland (FI) | 45874c47-f550-4a1e-90be-21f9464539b2 Netherlands (NL) | 2d311423-3743-428f-b5b0-ff09fd98627c Netherlands (NL)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1BE3063AFF000XXX
E-Number (Finland)
3602496
E-Number (Norway)
4309606
EAN
8015644694470
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.135 kg
Package Level 1 EAN
8015644694470
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.3 W
Rated Current (In)
63 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
630 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 25 kA | (230 V AC) 25 kA | (240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 18 kA | (440 V AC) 11.25 kA | (500 V AC) 8 kA | (525 V AC) 6 kA | (690 V AC) 3 kA | (250 V DC) 2 Poles in Series 18 kA | (500 V DC) 3 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 25 kA | (230 V AC) 25 kA | (240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 18 kA | (440 V AC) 15 kA | (500 V AC) 8 kA | (525 V AC) 6 kA | (690 V AC) 3 kA | (250 V DC) 2 Poles in Series 18 kA | (500 V DC) 3 Poles in Series 18 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
44.1...63 A
Short-Circuit Performance Level
B
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Front terminals and fixed 3P construction speed installation and reduce wiring errors, delivering safer, more reliable terminations in rugged environments. The 6 N·m tightening torque on bolt terminals ensures consistent connections with minimal loosening under vibration, ideal for switchgear and panel boards. The TM release with setting range of 44.1–63 A enables precise protection coordination, reducing nuisance trips and improving uptime for critical lines and motors. With a rated current of 63 A and a rated voltage of 690 V, this breaker supports flexible protection schemes for feeders, transformers, and distribution panels in manufacturing and processing facilities. Its high fault-withstand capability (Icu up to 25 kA; Ics up to 25 kA across listed voltages) enhances safety and selectivity in dense electrical rooms. Electrical durability of up to 8,000 cycles and mechanical durability up to 25,000 cycles provide long service life in high-demand environments, while features like front-terminal design and RoHS/CE compliance support sustainable, compliant asset management.
Get a Quick Quote for a ABB 1SDA066805R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA066805R1?
Enquire Now
FAQs
Install using the front terminals and ensure the busbar connection is within the 45.5 to 80 mm² range. Tighten each bolt to 6 N·m and verify the front-access wiring for correct polarity and secure, vibration-resistant connections. The 3P configuration simplifies wiring; verify that the assembly remains accessible for periodic maintenance.
The breaker has a rated current of 63 A and a rated voltage of 690 V. It provides Icu up to 25 kA and Ics up to 25 kA (depending on voltage), with Ui of 800 V and a setting range of 44.1–63 A. It operates at 50/60 Hz and uses a TM release in a fixed XT1 3P configuration.
Yes. The device complies with IEC 60947-2 and carries CE conformity. It is RoHS compliant, aligning with environmental and regulatory expectations for modern electrical installations in industrial facilities.
It is well-suited for power distribution feeders, transformer protection, motor control centers, and switchgear in manufacturing, processing plants, and data centers. The front-terminal design and high Icu/Ics ratings enable reliable protection of critical loads while simplifying panel layouts and future expansion.
Expect electrical durability up to 8,000 cycles and mechanical durability up to 25,000 cycles, supporting long intervals between maintenance. End-of-life guidance includes disassembly instructions, recycling considerations per EN45555, and access to EPD data for sustainability reporting and lifecycle cost management.