ABB 1SDA066807R1 Moulded Case Breaker - XT1B 3P IEC60947-2
Part Number: 1SDA066807R1
Quick Summary
ABB 1SDA066807R1 Moulded Case Breaker is a high-capacity protective device for distribution panels in industrial automation. Engineers often struggle with precise tripping settings and front-terminal configurations during panel upgrades. It carries IEC 60947-2 compliance, CE declaration, and LR certification to support global installations. With XT Tmax XT compatibility and front-terminal mounting, it enables reliable protection with easy integration into modern MCCs, reducing install time and lifecycle costs. Designed for 100 A nominal current with a fixed 3P configuration and front-terminal access, it streamlines panel wiring and reduces field wiring errors. Lifecycle benefits include robust mechanical durability and ease of service with standard front-mount terminals and clear wiring diagrams. In practice, maintenance teams report faster replacement cycles and lower spare-part inventory when stocking XT1 variants.
Product Information
Extended Description
1SDA066807R1 ABB: C.BREAKER TMAX XT1B 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 100-1000 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
87da4ae5-d281-4cf7-89ae-08ea1f34c520 Italy (IT)
Simplified SCIP
e1a75a7e-0f06-4343-b305-b0bb07d627d7 Germany (DE) | 9136ee1a-0225-4485-8008-9b9b4f898003 France (FR) | baa691e3-fb96-4aa9-9079-885f0ce9ffc7 Netherlands (NL) | 19009d20-fe0a-406e-a6c7-754e2ce79a04 Spain (ES) | 0d017bbc-bd89-4cba-9c40-ce382b69c941 Netherlands (NL) | 1ac23e01-8938-4cfa-9554-5dc725569cd9 Estonia (EE) | 3caf7a98-6d33-4e3d-9e3c-3696071c018c Greece (GR) | b4a8fa85-471c-4024-9dfa-2b3b8002b1fd Portugal (PT) | 40ae467e-12cd-4ff4-9b7b-0b06c10682c8 Bulgaria (BG) | 34e0ba7e-9ada-4036-a46c-78818d351a10 Sweden (SE) | 7688f27b-0303-4931-a1b9-201ec758eed9 Poland (PL) | 2973e92d-a825-4905-b178-8271043cd3fc Netherlands (NL) | 88dd4d2a-48ef-40e5-a5a4-8777e0caf1ae Poland (PL) | 28af0011-3352-4568-ae2e-5c6f712f69ce Norway (NO) | 139a4e60-c144-4385-9f47-109d95a5e80f Finland (FI) | fdaa062c-f086-4a1a-84ad-e07827068768 Netherlands (NL) | b45b713c-aac6-486d-860d-62c7bd566c76 Germany (DE) | 7cd9e27b-8379-4d1d-9c10-2494ae68a5e5 Denmark (DK) | b5672789-5124-44cd-b9aa-10e3f35aba7a Germany (DE) | 4b159a82-b08b-4bd6-9325-11ce5cdf5448 Croatia (HR) | dde32885-1587-472c-b2dd-1326e5aad4e2 Czech Republic (CZ) | f4f530b5-c734-46f4-9e51-1699fa3f6f95 Poland (PL) | 7684609b-1286-40fa-be35-8e161c571a09 Netherlands (NL) | 53567a62-c858-4312-a586-9c3dff2aeb2a France (FR) | 97a62aeb-f463-485d-802c-da5b271e1915 Sweden (SE) | 706a0ec2-b9e6-48d8-a2e7-e213302d4bc2 Germany (DE) | 6f865dc7-914e-4ee1-bd3b-f9f2de603622 Germany (DE)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1BE3100AFF000XXX
E-Number (Finland)
3640495
E-Number (Norway)
4309608
EAN
8015644694487
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.134 kg
Package Level 1 EAN
8015644694487
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 7 W
Rated Current (In)
100 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
1000 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 25 kA | (230 V AC) 25 kA | (240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 18 kA | (440 V AC) 11.25 kA | (500 V AC) 8 kA | (525 V AC) 6 kA | (690 V AC) 3 kA | (250 V DC) 2 Poles in Series 18 kA | (500 V DC) 3 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 25 kA | (230 V AC) 25 kA | (240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 18 kA | (440 V AC) 15 kA | (500 V AC) 8 kA | (525 V AC) 6 kA | (690 V AC) 3 kA | (250 V DC) 2 Poles in Series 18 kA | (500 V DC) 3 Poles in Series 18 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
70...100 A
Short-Circuit Performance Level
B
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front-terminal fixed mounting enables straightforward wiring and faster installation. Business Impact: Reduces wiring errors and commissioning time, lowering on-site labor costs. Application: Ideal for new panel builds and retrofits in power distribution cabinets. Feature: Thermomagnetic release (TMD) with adjustable setting range 70–100 A provides selective protection. Business Impact: Enhances motor and circuit protection without nuisance trips, improving uptime. Application: MCCs and transformer feed circuits in manufacturing plants. Feature: High voltage rating and robust insulation (690 V U r, Ui 800 V) expands compatibility. Business Impact: Supports mixed-voltage systems and helps standardize protection across equipment fleets. Application: Industrial facilities with multi-volt distributions. Feature: High short-circuit ratings (Ics up to 25 kA, Icu up to 25 kA) and 8 kV impulse withstand (Uimp) ensure safety under fault conditions. Business Impact: Reduces risk of cascading failures and protects critical loads. Application: Data centers, process industries, and heavy machinery lines. Feature: 3P fixed construction with bolt terminals and a tightening torque of 6 N·m improves mechanical reliability. Business Impact: Improves vibration resistance and field reliability in rugged environments. Application: Enclosures subjected to vibration or intermittent handling. Feature: Compliance and documentation streamlines audits (IEC 60947-2, CE DoC, LR). Business Impact: Supports regulatory filings and customer specifications with clear traceability. Application: Global deployments in regulated markets. Feature: Wiring and installation support through documented diagrams (Wiring Diagram XT1, Mechanical Drawings). Business Impact: Accelerates commissioning and reduces commissioning errors. Application: Panel builders and field service teams. Feature: EcoSolutions alignment and recyclability considerations. Business Impact: Supports sustainable asset management and end-of-life strategies. Application: Green initiatives in maintenance programs and supplier sustainability audits.
Get a Quick Quote for a ABB 1SDA066807R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA066807R1?
Enquire Now
FAQs
This model is a fixed 3P MCCB with front-terminal connections designed for quick wiring in control panels. It uses bolt terminals and a 6 N·m tightening torque, supporting busbar connections between 45.5 and 80 mm². The front-terminal configuration simplifies wiring during retrofit projects and new installations, reducing assembly time and improving wiring clarity in dense panel spaces.
The device is rated at 100 A with a rated voltage of 690 V (AC) / 500 V (DC). It offers a setting range of 70–100 A and a short-circuit protection capacity up to 25 kA (Ics) depending on voltage, with an instantaneous setting (Ii) up to 1000 A. It also features a 8 kV impulse withstand, ensuring resilience against electrical surges in demanding environments.
The XT1B 3P MCCB complies with IEC 60947-2 and carries a CE declaration of conformity along with LR certification. These certifications facilitate global deployment and provide assurance during audits and regulatory reviews, while also aligning with ABB EcoSolutions documentation for end-of-life and recyclability considerations.
Ideal for power distribution panels in industrial automation, machine controls, MCCs, and transformer protection schemes. Its 690 V rating and 100 A nominal current suit mid-to-large plant sections, while the 3P fixed design, front terminals, and TMD release support efficient protection for motors and critical loads in manufacturing, process industries, and energy infrastructure projects.
Expect reduced maintenance downtime due to reliable mechanical durability (25,000 cycles) and a clear, compact wiring path via front terminals. The 6 N·m torque and documented wiring diagrams simplify replacements and service. Long-term ROI comes from lower fault incidence, faster commissioning, and compatibility with XT Tmax XT family to standardize protection across multiple assets.