ABB 1SDA066810R1 Moulded Case Breaker - XT1 4P TMD

Part Number: 1SDA066810R1
Manufacturer
ABB
Part number
1SDA066810R1

Quick Summary

ABB 1SDA066810R1 is a moulded case circuit breaker protecting LV distribution and motor feeders. Engineers often contend with limited space, challenging protection coordination, and front-access installation when upgrading switchgear. Key certifications include CE conformity (EC Declaration of Conformity), LR and GL certification, and RoHS/REACH declarations, underpinning reliability and regulatory compliance. With the XT1 Tmax XT lineage and a front-terminal 4P design, it supports easy installation in compact panels while delivering predictable trip performance and long service life for industrial automation applications.

Product Information

Extended Description

1SDA066810R1 ABB: C.BREAKER TMAX XT1B 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 16-450 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1BE4016AFF000XXX
E-Number (Finland)
3640502
E-Number (Norway)
4309700
EAN
8015644007171
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8015644007171
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 1.5 W
Rated Current (In)
16 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
450 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 25 kA | (230 V AC) 25 kA | (240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 18 kA | (440 V AC) 11.25 kA | (500 V AC) 8 kA | (525 V AC) 6 kA | (690 V AC) 3 kA | (250 V DC) 2 Poles in Series 18 kA | (500 V DC) 3 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 25 kA | (230 V AC) 25 kA | (240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 18 kA | (440 V AC) 15 kA | (500 V AC) 8 kA | (525 V AC) 6 kA | (690 V AC) 3 kA | (250 V DC) 2 Poles in Series 18 kA | (500 V DC) 3 Poles in Series 18 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
11.2...16 A
Short-Circuit Performance Level
B
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front-terminal bolt connections for the main circuit. Impact: Simplifies wiring, reduces install time, and improves safety during maintenance by keeping conductors protected and accessible. Application: Ideal for compact switchgear where space is at a premium and quick field servicing is required in panelboards and distribution boards. Feature: Rated current In of 16 A with a setting range of 11.2–16 A. Impact: Enables precise protection coordination with upstream devices, minimizing nuisance trips while preserving motor and feeder integrity. Application: Motor feeders and small distribution circuits in automation panels benefit from tailored protection. Feature: High fault current capability with Icu up to 25 kA and Ics up to 25 kA depending on voltage. Impact: Delivers robust short-circuit protection and improved system resilience in industrial environments. Application: Critical loads and transformer-fed circuits in factory automation and data-center infrastructure require reliable fault interruption. Feature: Rated voltage 690 V and Ui 800 V with IEC 60947-2 compliance. Impact: Broad compatibility with LV networks and peace of mind on regulatory compliance. Application: Suitable for modern switchgear that combines high nominal voltage with compact form factors. Feature: Tmax XT TM release (TMD) and 4P fixed front terminals. Impact: Supports selective tripping and straightforward field maintenance, reducing downtime. Application: Protective schemes demanding fast, predictable operation in panel installations across manufacturing lines and process control.

Get a Quick Quote for a ABB 1SDA066810R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA066810R1? Enquire Now

FAQs

This unit uses front-terminal bolt connections for the main circuit, supporting 4 poles and a fixed front-terminal configuration. It is designed for busbar connections in the 45.5 to 80 mm² range and accepts a 6 N·m tightening torque. This makes installation straightforward in compact switchgear and panel boards, minimizing wiring space and enabling safer maintenance.
The setting range allows precise adjustment of the breaker’s minimum tripping current to match upstream protection and motor inrush characteristics. By coordinating with upstream devices, you can reduce nuisance trips while ensuring fast clearance of actual faults. This is especially important for motor feeders in automation lines where selective protection preserves system uptime.
Yes. The unit complies with IEC 60947-2, evidenced by the DoC for CE conformity and the SACE Tmax XT family documentation. It also carries RoHS and REACH declarations, aligning with European environmental regulations. This makes it suitable for regulatory-compliant installations in modern factories and data centers.
Front-terminal design facilitates quick wiring, simplifies testing, and reduces panel depth by allowing cables to be connected from the front. The 6 N·m tightening torque ensures reliable connections for the busbar range, while the fixed 4P arrangement supports fast, repeatable installations in space-constrained switchgear used in manufacturing and process control.
The XT1 4P TM delivers predictable mechanical and electrical performance with long service life, supported by a rated short-circuit capacity appropriate for LV networks. With a reported electrical durability of up to multiple cycles and a stable power loss of about 1.5 W per pole, maintenance intervals are minimized, contributing to lower total cost of ownership in automation plants.