ABB 1SDA066817R1 Moulded Case Circuit Breaker XT1 - IEC60947-2
Part Number: 1SDA066817R1
Quick Summary
ABB Moulded Case Circuit Breaker XT1 4P 80A 690V protects distribution panels and transformer feeders with fixed front-terminal design. Engineers often struggle with wiring access in tight panels and the need for reliable, scalable protection settings. This device carries IEC 60947-2 compliance, a CE declaration of conformity, and GL and LR certificates, strengthening regulatory alignment and supplier trust. With a setting range of 56–80 A, a rated insulation voltage of 800 V, and a short-circuit capacity up to 25 kA, it delivers robust, predictable trips. By combining front-terminal mounting, a compact footprint, and low power loss, it enables faster installation, easier maintenance, and longer equipment uptime in industrial environments.
Product Information
Extended Description
1SDA066817R1 ABB: C.BREAKER TMAX XT1B 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 80-800 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
a943ed44-4235-453a-beee-ce834cf372fe Italy (IT)
Simplified SCIP
0147d83e-c5d7-413e-8f24-65b8e1b6fb4d Germany (DE) | b431f35b-1f96-490a-a7c2-8a6cc22f7500 Poland (PL) | 215798aa-2b02-41bd-9634-302747961651 Norway (NO) | 4eac72ff-892f-4ff2-82d0-c21e9c520485 Finland (FI) | efe375a4-bcdf-46ce-a558-ba03c12e488c Netherlands (NL) | bc484707-a31e-45e2-8375-a4605a0c4163 Germany (DE) | b1b3e14c-e8f6-4289-b7fc-d5aab4ce816f Denmark (DK) | 60a91a61-9ead-49e6-8169-7cda04c66dcd Germany (DE) | 0326c47c-dd79-450d-b2bd-3d90fcbbbc4c Croatia (HR) | 162f37d5-e57a-4b76-8f36-7384684e8f01 Czech Republic (CZ) | 2e827726-64d3-4efc-87ec-22462d26739a Poland (PL) | 3d3a7694-b98a-41bc-9530-b47abf21d453 Netherlands (NL) | 4b35c0e4-2d12-48d0-8c90-0b8f127892f0 Netherlands (NL) | 184dcce7-b47b-4d71-8c62-71cc3f45eb4e Estonia (EE) | ab562bd1-1c53-40ee-9227-2941b5adde00 Greece (GR) | 0bb6b765-9c71-49a8-ad40-36690b1c84e0 Portugal (PT) | 748e83e4-abf3-4533-b1ab-dfec7b8ee96b Bulgaria (BG) | 21d8766a-ee24-4074-8732-011203fd325e Sweden (SE) | 0f24ea69-2cc1-49f6-83a2-c35c70d09681 Poland (PL) | 0714bd13-a38c-445f-b771-3b1a6bc968c7 France (FR) | 0982874d-1466-4556-b90a-9b28af9b7c80 Sweden (SE) | 18632971-3a27-4fe2-957a-d38b0dbc8455 Germany (DE) | 066fc8b9-f695-4901-a8cc-fcfd4d6e6e0e Germany (DE) | 660b252b-f02a-40ad-836d-d91f2d82d400 France (FR) | 91cce256-25f2-4ed6-9157-f274842bbd7c Netherlands (NL) | 083afd60-1e8b-4a2f-bf73-8058f41740fe Spain (ES) | e9ef4ee6-d181-4131-a42a-ff4646e1ee6d Netherlands (NL)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1BE4080AFF000XXX
E-Number (Finland)
3638190
E-Number (Norway)
4309707
EAN
8015644694531
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.448 kg
Package Level 1 EAN
8015644694531
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.8 W
Rated Current (In)
80 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
800 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 25 kA | (230 V AC) 25 kA | (240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 18 kA | (440 V AC) 11.25 kA | (500 V AC) 8 kA | (525 V AC) 6 kA | (690 V AC) 3 kA | (250 V DC) 2 Poles in Series 18 kA | (500 V DC) 3 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 25 kA | (230 V AC) 25 kA | (240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 18 kA | (440 V AC) 15 kA | (500 V AC) 8 kA | (525 V AC) 6 kA | (690 V AC) 3 kA | (250 V DC) 2 Poles in Series 18 kA | (500 V DC) 3 Poles in Series 18 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
56...80 A
Short-Circuit Performance Level
B
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Front terminals and fixed XT1 design simplify wiring and reduce installation time in control panels, improving site productivity and reducing labor costs while enhancing wiring accessibility during maintenance. Application: New panel builds and retrofit projects on 690 V feeders. Feature → Business Impact → Application: Thermomagnetic release with TMD provides fast, reliable tripping under overload and short circuits, minimizing downtime and protecting upstream equipment. Application: Transformer and distribution board protection in manufacturing lines. Feature → Business Impact → Application: 56–80 A setting range and 80 A rated current enable precise feeder protection without over-sizing, lowering energy waste and enabling accurate coordination with upstream devices. Application: Industrial power distribution with variable load profiles. Feature → Business Impact → Application: High Icu up to 25 kA and Ui of 800 V ensure robust short-circuit withstand and safe insulation in 690 V systems, supporting compliance with IEC 60947-2 and client safety standards. Application: Large-scale motor control centers and processor panels. Feature → Business Impact → Application: Front connection and 6 N·m tightening torque, plus 101.6 mm width, streamline installation in compact enclosures and reduce commissioning time. Application: Retrofit projects and retrofits in space-constrained cabinets. Feature → Business Impact → Application: 8000 electrical cycles and 25000 mechanical cycles deliver long service life and lower lifecycle costs, improving total cost of ownership for critical protection devices. Application: Continuous operation environments such as packaging, metals, and process industries. Feature → Business Impact → Application: RoHS/REACH compliance, EPD documentation, and SCIP registrations provide regulatory assurance and sustainability signaling for procurement programs. Application: Global supply chains demanding eco-friendly components.
Get a Quick Quote for a ABB 1SDA066817R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA066817R1?
Enquire Now
FAQs
The 1SDA066817R1 is designed for the SACE Tmax XT family with fixed front terminals, enabling straightforward wiring in XT1 configurations. It supports standard busbar connections and a tightening torque of 6 N·m. When upgrading or retrofitting, ensure enclosure clearance for the 101.6 mm width and verify conductor sizes up to 80 mm².
Key specs include Rated Current I n of 80 A, Rated Voltage U r of 690 V, Rated Impulse Withstand Voltage U i p of 8 kV, Short-Circuit Breaking Capacity I c u up to 25 kA, and Setting Range of 56–80 A. The release is TMD, with a 4P configuration and front-terminal connection suitable for 690 V distribution panels.
Yes. With 690 V rated operation, front-terminal mounting, and a robust 25 kA short-circuit rating, this MCCB is well-suited for 690 V feeders, transformer protection, and panel boards in manufacturing, process industries, and energy infrastructure projects demanding reliable, trip-ready protection.
The device carries a CE Declaration of Conformity and GL and LR certificates, supporting regulatory compliance and supplier qualification. It aligns with IEC 60947-2. SCIP entries and RoHS/REACH declarations are provided, reinforcing environmental responsibility and traceability in procurement.
Expect lower maintenance downtime due to high durability: 8000 electrical cycles and 25000 mechanical cycles. The front-terminal design reduces wiring time during installation, while low power loss (4.8 W per pole) helps reduce heat and energy waste. These factors combine to shorten payback periods in upgrades and improve overall system reliability.