ABB 1SQA718941R0001 MCCB - Enclosed XT7 EC000228
Part Number: 1SDA067272R1
Quick Summary
ABB MCCB provides robust overcurrent protection for industrial power distribution and transformer circuits. Installers often struggle with enclosure compatibility and safe integration in tight spaces, especially in retrofits or constrained switchgear rooms. This device aligns with ETIM 9 EC000228 for power circuit-breaker classification, UNSPSC 39121616, and WEEE compliance, supporting global procurement and end-of-life handling. The Enclosed XT7 design simplifies installation and service, while the embedded labeling aids diagnostics and inventory control. For engineers, the combination of ABB's XT7 enclosure and MCCB platform delivers predictable performance in protective schemes, enabling quick fault isolation and reduced downtime. Secondary benefits include common spare-part inventories and streamlined maintenance planning for transformer protection and distribution networks.
Product Information
Extended Description
1SDA067272R1 ABB: SG.TMG 20-160 XT2 4p
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
EAN
8015644011758
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
0 mm
Package Level 1 Height
0 mm
Package Level 1 Depth / Length
0 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644011758
Circuit Breaker Type to be Associated
Generator Protection
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT2
Suitable for Product Class
SACE Tmax XT
Configuration Type
Loose or configurable
Current Type
AC/DC
Number of Poles
4P
Rated Current (In)
20 A
Release
TMG
Release Type
TM
Standards
IEC60947-2
Data Sheet, Technical Information
1SDC210100D0205 | 1SDC210099D0205
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Release assembly XT2-XT4
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
Enclosed XT7 design enables straightforward installation and service access, reducing field wiring time and leakage risks while protecting the MCCB from dust and moisture. This translates to measurable uptime gains and lower life-cycle costs in harsh industrial environments. The XT7 enclosure also simplifies compatibility with ABB ECB TMAX XT and XB7 series switchgear, shortening commissioning time and lowering engineering risk during panel upgrades. By conforming to ETIM 9 EC000228 and UNSPSC 39121616, procurement and cross-brand sourcing become more predictable, with better traceability and streamlined spare-part management. The WEEE compliant classification ensures responsible end-of-life handling, supporting sustainability objectives and regulatory alignment across multi-site deployments. Overall, the enclosed MCCB enables reliable fault isolation, reduced maintenance windows, and consistent protection for transformers and critical power distribution networks. Engineers also benefit from clear labeling and standardised components that fit inside compact enclosures while maintaining high protection performance.
Get a Quick Quote for a ABB 1SDA067272R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067272R1?
Enquire Now
FAQs
Install the ABB 1SQA718941R0001 MCCB by mounting the Enclosed XT7 unit into the switchgear chamber, wiring per the enclosure's terminal diagram, and securing with the XT7 mounting provisions. Ensure alignment with terminal torque specs and verify the unit’s protective rating for the intended environment. The XT7 enclosure simplifies access for future maintenance and fault testing while preserving enclosure integrity.
This MCCB is designed as a protected, enclosed XT7 device for transformer/generator protection. It carries ETIM 9 EC000228 classification and UNSPSC 39121616 categorization, with EAN 783164691276 and Customs Tariff 8536200020. While exact amperage and breaking capacity depend on the installation module, the XT7 enclosure supports reliable overcurrent protection in industrial power distributions.
Yes. The Enclosed XT7 MCCB is designed for transformer protection within industrial power distribution. The enclosure provides a robust barrier against dust and moisture, helping maintain performance in challenging environments. Its compatibility with XT7-based switchgear ensures streamlined integration with standard protective schemes for transformers and related installations.
The product aligns with ETIM 9 EC000228 for power circuit-breaker classification, UNSPSC 39121616 for procurement taxonomy, and WEEE categories for end-of-life handling. It also uses labeling and product information consistent with ABB’s XT7 enclosed MCCB family, facilitating regulatory compliance and global sourcing.
The enclosed XT7 MCCB enables faster deployment, standardized spare parts, and predictable maintenance schedules, reducing downtime and inventory complexity. Its compatibility with ABB TMAX XT and XB7 series minimizes engineering effort during upgrades, while ETIM/UNSPSC alignment improves procurement efficiency and lifecycle management across multi-site operations.