ABB 1SDA067387R1 Accessory - IEC60947-2
Part Number: 1SDA067387R1
Quick Summary
ABB 1SDA067387R1 Accessory is a three-pole thermomagnetic release for Tmax XT circuit breakers in AC-DC applications. Engineers frequently confront downtime, misalignment, and complex wiring when upgrading protection schemes, making reliability and installation speed critical. This accessory complies with IEC60947-2 and carries RoHS and CMRT declarations, with CE compatibility for European installations. Designed for XT4 configurations, it reduces wiring complexity, shortens commissioning time, and supports safer preventive maintenance, delivering tangible business value in modern power distribution environments.
Product Information
Extended Description
1SDA067387R1 ABB: THERMOMAGNETIC RELEASE THREE-POLE IN AC-DC TMA R 160 I3=800...1600 A XT4
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
E-Number (Finland)
3641159
E-Number (Norway)
4380036
EAN
8015644012878
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
162 mm
Package Level 1 Height
92 mm
Package Level 1 Depth / Length
100 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644012878
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT4
Suitable for Product Class
SACE Tmax XT
Configuration Type
Loose or configurable
Current Type
AC/DC
Number of Poles
3P
Order Multiple
1 piece
Rated Current (In)
160 A
Release
TMA
Release Type
TM
Standards
IEC60947-2
Data Sheet, Technical Information
1SDC210100D0205 | 1SDC210099D0205
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Release assembly XT2-XT4
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
Feature: Three-pole thermomagnetic release (AC/DC) rated for 160 A in a 3P configuration. Business Impact: Delivers predictable, coordinated tripping across all phases, minimizing nuisance trips and protecting downstream equipment. Application: Ideal for Tmax XT main distribution sections in industrial panels. Feature: Loose or configurable mounting option. Business Impact: Enables flexible installation and rapid retrofits in crowded or retrofit panels, reducing labor time and installation risk. Application: Suitable for upgrading existing XT4 installations without extensive rework. Feature: Full regulatory compliance package (IEC60947-2, CE, RoHS, CMRT, TSCA). Business Impact: Reduces compliance-related delays and audit findings while supporting global manufacturing footprints. Application: Critical for multinational facilities and supplier certifications. Feature: Environmental and packaging information (Environmental Declaration, packaging disposal). Business Impact: Supports sustainability commitments and simplifies end-of-life handling, aligning with corporate ESG goals. Application: Logistics planning for large-scale deployments. Feature: Clear product data and compatibility (XT4 suitability, EAN, E-number). Business Impact: Improves procurement accuracy and reduces misorders, speeding up sourcing cycles. Application: Streamlined integration into standard Tmax XT protection schemes. Feature: Weight and packaging metrics (1 kg net, 1.1 kg boxed). Business Impact: Improves stock planning and shipping efficiency, lowering logistics cost. Application: Warehouse and distribution optimization for high-mix SKUs.
Get a Quick Quote for a ABB 1SDA067387R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067387R1?
Enquire Now
FAQs
Begin by confirming AC/DC compatibility for 3P operation at 160 A. Mount the three-pole release accessory to the Tmax XT frame according to the XT2–XT4 assembly instructions, ensuring proper seating and alignment of all contacts. Verify torque specifications, wiring integrity, and that the release lever operates freely through the full travel. Finally, perform functional tests to confirm correct trip signaling and coordination within the XT protection scheme.
The unit is a three-pole AC/DC thermomagnetic release rated for 160 A (In), with a Release type TM and Release name TMA. It is designed for three-phase systems and adheres to IEC60947-2. It supports XT4 configurations and is compatible with Tmax XT protection schemes, providing reliable tripping and coordinated protection across all phases.
Yes. This accessory is specifically specified for Xt4 configurations and is designed to integrate with Tmax XT three-pole breakers. It enhances trip performance in AC-DC environments and simplifies wiring, mounting, and maintenance in panelboards used for distribution, machine control, and industrial power distribution applications.
The accessory complies with IEC60947-2, and it includes RoHS declarations, CMRT, TSCA declarations, and CE compliance for European installations. Acknowledging these certifications helps meet regulatory requirements, support sustainability goals, and reduce risk during audits and supplier assessments.
By delivering reliable tripping with exact phase coordination, this accessory minimizes nuisance trips and reduces unplanned downtime. Faster commissioning and easier retrofits lower labor costs, while RoHS and CMRT/TSCA compliance streamline procurement and risk management for multi-site operations, contributing to lower total cost of ownership over the protection system’s life cycle.