ABB 1SDA067389R1 Shunt Release (XT) - IEC60947-2
Part Number: 1SDA067389R1
Quick Summary
ABB 1SDA067389R1 shunt release for Tmax XT provides precise trip control for three-pole protection in high-demand AC-DC circuits. Engineers often grapple with coordinating main and release devices, prolonging commissioning and increasing the risk of mis-tripping under dynamic loads. This accessory aligns with IEC 60947-2 and carries CE conformity, RoHS, CMRT and TSCA disclosures to support global installations. As a Tmax XT accessory, it integrates with ABB ecosystems, reduces spare parts complexity, and delivers measurable improvements in protection reliability and total cost of ownership.
Product Information
Extended Description
1SDA067389R1 ABB: THERMOMAGNETIC RELEASE THREE-POLE IN AC-DC TMA R 225 I3=1125...2250 A XT4
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
E-Number (Finland)
3641169
E-Number (Norway)
4380038
EAN
8015644012892
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
162 mm
Package Level 1 Height
92 mm
Package Level 1 Depth / Length
100 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644012892
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT4
Suitable for Product Class
SACE Tmax XT
Configuration Type
Loose or configurable
Current Type
AC/DC
Number of Poles
3P
Order Multiple
1 piece
Rated Current (In)
225 A
Release
TMA
Release Type
TM
Standards
IEC60947-2
Data Sheet, Technical Information
1SDC210100D0205 | 1SDC210099D0205
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Release assembly XT2-XT4
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
Feature: Three-pole AC/DC release (TMA) for Tmax XT provides coordinated trip across all poles. Business Impact: Improves selectivity and reduces arc exposure, cutting downtime during fault events. Application: Suitable for three-phase feeders in industrial power distribution panels and motor control centers. Feature: Rated current In 225 A with XT4 compatibility. Business Impact: Supports heavy-load applications without compromising protection, enabling consistent system performance. Application: Ideal for high-demand industrial circuits and data center feeder paths. Feature: Loose or configurable configuration type. Business Impact: Installation flexibility lowers retrofit time and simplifies field commissioning. Application: Works in new builds and retrofits alongside Tmax XT modules. Feature: IEC60947-2 compliance and CE declarations. Business Impact: Regulatory alignment with clear documentation reduces validation time during audits. Application: Global installations across European, Middle Eastern, and Asian markets. Feature: RoHS, CMRT, and TSCA compliance. Business Impact: Environmentally responsible supply chain and risk mitigation for responsible procurement. Application: End-use approvals in regulated markets with strict material controls. Feature: Compact packaging and 1 kg net weight. Business Impact: Easier handling and reduced on-site logistics costs. Application: Field installations in panel boards and compact switchgear racks.
Get a Quick Quote for a ABB 1SDA067389R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067389R1?
Enquire Now
FAQs
Installation involves mounting the shunt release onto the Tmax XT assembly, wiring per the release connection diagram, and confirming pole alignment for three-pole coordination. The process is designed for loose or configurable configurations and is supported by the referenced ABB manuals 1SDC210100D0205 and 1SDC210099D0205 to minimize commissioning time.
Key specs include 3P AC/DC release, rated current 225 A, release type TM/TMA, and IEC60947-2 conformity. It is designed for XT4 compatibility and supports 3641169 E-number in Finland and 4380038 in Norway, with EAN 8015644012892 ensuring traceability in procurement systems.
Yes, the accessory is suitable for Tmax XT configurations including XT4. It supports loose or configurable mounting, enabling flexible installation in existing switchgear and new panels. This reduces engineering time and enables straightforward field retrofits without major panel alterations.
The shunt release carries IEC 60947-2 compliance, CE Declaration, RoHS information, and CMRT/TSCA disclosures. These certifications support regulatory alignment for international projects and provide the documentation needed during audits and supplier qualification processes.
The 225 A rated release reduces the likelihood of mis-tripping and improves protection coordination, cutting unplanned downtime. Its compatibility with XT4 and straightforward installation lowers commissioning costs, while RoHS/CMRT/TSCA compliance reduces long-term risk and maintenance overhead across multi-site deployments.